• Title/Summary/Keyword: Dead Time Effect

Search Result 135, Processing Time 0.021 seconds

The Pitch/Turning Control Driver Design Modeling of Permanent Magnet Synchronous Motor (영구자석형 동기전동기의 고저/선회 제어용 드라이버 설계 모델링)

  • Lee, Chun-Gi;Hwang, Jeong-Won;Lee, Joung-Tae;Yang, Bin;Lim, Dong-Keun;Park, Seung-Yub
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.219-225
    • /
    • 2014
  • The purpose of this paper is to control of the low-speed, high-precision PMSM 2-axes pitch/turning. In this paper, apply the PAM-PWM inverter for it. However, The PAM-PWM inverter, control algorithms and hardware is complex. But it is possible to improve the performance in the low-speed operation can reduce the effect of the PWM ripple and Dead Time of inverter by applying suitable DC-bus voltage control. The direct driver PMSM(Permanent Magnet Synchronous Motor) configured to vector control part, PAM control part and the other controller. The vector control part includes PI current, speed control, additional space vector modulation. PAM control part has to have PI voltage controller and P current controller for DC-bus voltage control. Besides, the motor position estimator, the speed estimator and the counter electromotive force and Dead Time Compensation are added. With this arrangement, PMSM was driven with a low pole pitch/turning by performing the current control to the current command or torque command is the paper. As a result, it was possible to minimize the disturbance component that appears in the drive in proportion to the DC voltage magnitude. The use of a hydraulic drive method for a two-axis bubble column is a typical tank. When using the PWM PAM inverter driver is in the turret can be driven by high-precision, low vibration, low noise compared to the hydraulic drive may contribute to the computerization of the turret.

Treatment Time and Concentration of GA3 for Increasing Efficiency of the Lettuce Seed Production for Lettuce Breeding and Selection (상추 육성 및 선발을 위한 채종 효율증진을 위한 GA3 처리시기 및 농도)

  • Lee, K.H.;Ryu, G.M.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.14 no.1
    • /
    • pp.119-130
    • /
    • 2012
  • To increasing efficiency of the seed production through GA3 treatment, treatment of GA3 20mg/ℓ at its fourteen leaf stage had an effect on 21% increasing seed yield at leaf lettuce (cv.'Ttugseomjeokchugmyeon') in seed production from 50.9ℓ/10a to 61.7ℓ/10a, and 'GA3 50mg/ℓ at its eight leaf and fourteen leaf stage had a effect on 14% increasing the seed yield of head lettuce (cv.'Urake') at seed production from 14.2ℓ/10a to 21.1ℓ/10a reducing rate of dead plant in field. Especially, it will be recommended for planting after June for seed production of head lettuce owing to decreasing rate of dead by soft rot and stem rot.

Phototoxic effect of blue light on the planktonic and biofilm state of anaerobic periodontal pathogens

  • Song, Hyun-Hwa;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok;Lee, Si-Young;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.2
    • /
    • pp.72-78
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the phototoxic effects of blue light exposure on periodontal pathogens in both planktonic and biofilm cultures. Methods: Strains of Aggregatibacter actinomycetemcomitans, Fusobacterium nucleatum, and Porphyromonas gingivalis, in planktonic or biofilm states, were exposed to visible light at wavelengths of 400.520 nm. A quartz-tungsten-halogen lamp at a power density of $500mW/cm^2$ was used for the light source. Each sample was exposed to 15, 30, 60, 90, or 120 seconds of each bacterial strain in the planktonic or biofilm state. Confocal scanning laser microscopy (CSLM) was used to observe the distribution of live/dead bacterial cells in biofilms. After light exposure, the bacterial killing rates were calculated from colony forming unit (CFU) counts. Results: CLSM images that were obtained from biofilms showed a mixture of dead and live bacterial cells extending to a depth of $30-45{\mu}m$. Obvious differences in the live-to-dead bacterial cell ratio were found in P. gingivalis biofilm according to light exposure time. In the planktonic state, almost all bacteria were killed with 60 seconds of light exposure to F. nucleatum (99.1%) and with 15 seconds to P. gingivalis (100%). In the biofilm state, however, only the CFU of P. gingivalis demonstrated a decreasing tendency with increasing light exposure time, and there was a lower efficacy of phototoxicity to P. gingivalis as biofilm than in the planktonic state. Conclusions: Blue light exposure using a dental halogen curing unit is effective in reducing periodontal pathogens in the planktonic state. It is recommended that an adjunctive exogenous photosensitizer be used and that pathogens be exposed to visible light for clinical antimicrobial periodontal therapy.

The effect of front edge on efficiency for point and volume source geometries in p-type HPGe detectors

  • Esra Uyar ;Mustafa Hicabi Bolukdemir
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4220-4225
    • /
    • 2022
  • Monte Carlo (MC) simulations are increasingly being used as an alternative or supplement to the gamma spectrometric method in determining the full energy peak efficiency (FEPE) necessary for radionuclide identification and quantification. The MC method is more advantageous than the experimental method in terms of both cost and time. Experimental calibration with standard sources is difficult, especially for specimens with unusually shaped geometries. However, with MC, efficiency values can be obtained by modeling the geometry as desired without using any calibration source. Modeling the detector with the correct parameters is critical in the MC method. These parameters given to the user by the manufacturer are especially the dimensions of the crystal and its front edge, the thickness of the dead layer, dimensions, and materials of the detector components. This study aimed to investigate the effect of the front edge geometry of the detector crystal on efficiency, so the effect of rounded and sharp modeled front edges on the FEPE was investigated for <300 keV with three different HPGe detectors in point and volume source geometries using PHITS MC code. All results showed that the crystal should be modeled as a rounded edge, especially for gamma-ray energies below 100 keV.

Effects of Dietary Fish Oil on Semen Quality of Goats

  • Dolatpanah, M.B.;Towhidi, A.;Farshad, A.;Rashidi, A.;Rezayazdi, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • The aim of the study was to investigate the effect of dietary fish oil supplementation on the semen characteristics of the Markhoz buck. Sixteen bucks were randomly allocated into 4 groups and received four different diets: unsupplemented control diet, supplemented with fish oil at 2.50% dry matter (DM), supplemented with fish oil (2.50% DM) and vitamin E (0.30 g/kg DM), and supplemented with vitamin E (0.30 g/kg DM). All experimental diets were formulated according to AFRC (1998). Semen was collected at 14 d intervals from June 17, 2006 to September 2, 2006. Semen characteristics were evaluated. Significant effects (p<0.05) of the week (sampling time) were observed for all parameters except semen volume. Also a significant effect (p<0.05) of dietary treatment was observed for all parameters except for percent sperm with normal morphologies and semen volume. Fish oil supplementation with excess vitamin E had a significant effect (p<0.05) on total number and sperm density, motility and progressive motility, percentage viability and dead sperm. The interaction between fish oil feeding and sampling time was significant (p<0.05) for all of the parameters. The bucks that received fish oil in association with vitamin E, effect fish oil showed the greatest improvement in semen characteristics compared with the other groups (p<0.05). This study showed that fish oil supplementation with vitamin E may have a beneficial effect on the semen quality and fertility of Markhoz bucks.

Comparison of Short-Term Toxicity Tests Based on Feeding Behavior and Temperature Control by Ceriodaphnia dubia (Ceriodaphnia dubia의 먹이섭생 기작과 온도조절에 근거한 급성독성조사법의 비교)

  • Park, Jong-Ho;Lee, Sang-Ill;Cho, Young-Oak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.48-54
    • /
    • 2004
  • Two methods, a Ceriodaphnia algal uptake suppression test (CAUST) and a new toxicity test based on temperature control (TTBTC) which are based on feeding behaviour and temperature control, respectively, were developed and compared for the adoption as the better methodology for short-term toxicity screening. As previously published by Lee et aI., (1997), the CAUST method is based on the feeding behaviour of C. dubia and requires as little as 1 hour of contact time between C. dubia neonates and toxicant. However, even though CAUST requires only 1 hour of contact time, this method still take many hours for the preparation and measurement. Before the test starts, neonate digestive tracts were cleared by feeding yeast to the daphnids, Neonates were then exposed to toxicant, followed by addition of Scenedesmus subspiatus into the bioassay vessels. Daphnids were examined under the bright-field microscope with the presence of algae (indicated by a green colored digestive tract) or the absence of algae. Uptake indicated no toxic effect, whereas, absence of uptake indicated toxic inhibition. Unlike CAUST, the newly developed method (TTBTC) is based on just temperature control for the toxicity test of C. dubia. Initially, neonates are exposed to toxicants while the temperature of water bath containing media increased to $35.5^{\circ}C$. After 1.25 hour of contact time, the number of the daphnids, either live (no toxic effect) or dead (toxic effect), is counted without the aid of any instrument. In both methods, median effective concentrations ($EC_{50}$ values) were computed based on the results over a range of dosed toxicant concentrations. It showed that TTBTC was as sensitive as the standard 48-hour acute bioassay and CAUST. TTBTC and CAUST were much more sensitive than the I-hour I.Q. test and 30-minute Microtox. This study indicates that TTBTC is an easier and more rapid toxicity test than the standard 48-hour acute bioassay and even CAUST.

Rapid Bioassay Technique Based on Temperature Control of Ceriodaphnia dubia (Ceriodaphnia dubia의 온도조절에 근거한 단기급성독성 조사법)

  • PARK Jong Ho;LEE Sang Ill;CHO Young Oak;LEE Won Ho;YEON Ik Jun;CHO Kyu Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.3
    • /
    • pp.209-214
    • /
    • 2004
  • A method for rapid acute toxicity test based on temperature control of Ceriodaphnia dubia has been developed and evaluated. A new toxicity test based on temperature control (TTBTC) which are based on temperature control, was developed and compared for the adsorption of the better methodology for short-term toxicity screening. Initially, daphnid larval are exposed to toxicants and at the same time the temperature of the water bath containing media is increased to high temperature $(35.5^{\circ}C).$ After 1.25 hrs of contact time, the number of the daphnids, either living (no toxic effect) or dead (toxic effect), is counted by the naked eyes. Effect of exposure time on test sensitivity was not significantly different between 1 to 1.5 hr. Comparison of the rapid 1.25 hr acute toxicity test developed in this study and the standard 48 hr acute toxicity test using heavy metals, cyanide and pentachlorophenol indicated that the 1.25 hour test provides an acceptable level of sensitivity in toxicity test for C. dubia.

Dead-Time Effect Compensation Method in the Utilty-Interactive Inverter (계통연계형 인버터에서 데드타임 보상기법)

  • Byen, Byeng Joo;Han, DH;Seo, HU;Ban, CH;Kim, DJ;Choe, GH
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.42-43
    • /
    • 2011
  • 본 논문에서는 계통 연계형 단상 인버터의 데드타임을 보상할 수 있는 방법을 제안한다. 인버터의 데드타임 영향을 수식적인 분석을 통하여 고조파의 함유량을 정량적으로 파악하여 인버터 지령치에 보상신호를 더함으로써 출력 파형이 개선되는 것을 시뮬레이션으로 검증하였다.

  • PDF

A Study on a Carrier Based PWM having Constant Common Mode Voltage and Minimized Switching Frequency in Three-level Inverter

  • Ahn, Kang-Soon;Choi, Nam-Sup;Lee, Eun-Chul;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.393-404
    • /
    • 2016
  • In this paper, a carrier-based pulse with modulation (PWM) strategy for three-phase three-level inverter is dealt with, which can keep the common mode voltage constant with minimized switching frequency. The voltage gain and the switching frequency in overall operating ranges including overmodulation are investigated and the analytic equations are presented. Finally, the leakage current reduction effect is confirmed by carrying out simulation and experiment. It will be pointed out that the leakage current cannot be perfectly eliminated because of the dead time.

A Study on Current Ripple Reduction Due to Offset Error and Dead-time Effect of Single-phase Grid-connected Inverters Based on PR Controller (비례공진 제어기를 이용한 단상 계통연계형 인버터의 데드타임 영향과 옵셋 오차로 인한 전류맥동 저감에 관한 연구)

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.157-158
    • /
    • 2014
  • 단상 계통연계형 인버터에서 전류센서를 통한 상전류 측정시 옵셋 오차는 전류센서와 측정 경로상에 위치한 아날로그 소자의 전압 불균형 및 비선형성으로 인하여 발생하게 된다. 또한 데드타임은 전력용 반도체 스위치를 제어하기 위한 PWM 신호 출력시 필연적으로 발생된다. 본 논문에서는 데드타임으로 인하여 왜곡된 상전류에 포함된 옵셋 오차에 의한 영향을 분석하고 동기좌표계 dq축 전류에 포함된 특정 고조파 성분을 제거하기 위하여 PR 제어기를 사용한 알고리즘이 제안되었다. 데드타임 및 옵셋 오차로 인해 발생된 전류맥동 보상을 위한 기준신호로는 동기좌표계 dq축 전류를 사용하였다. 제안된 알고리즘의 타당성을 시뮬레이션과 실험을 통하여 증명하였다.

  • PDF