• Title/Summary/Keyword: De-icing analysis

Search Result 25, Processing Time 0.026 seconds

An Investigation of Icing Effects on the Aerodynamic Characteristics of KC-100 Aircraft (KC-100 항공기의 표면발생 Icing 형상 및 공력 영향성 연구)

  • Jung, Sung-Ki;Lee, Chang-Hoon;Shin, Sung-Min;Myong, Rho-Shin;Cho, Tae-Hwan;Jeong, Hoon-Hwa;Jung, Jae-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.6
    • /
    • pp.530-536
    • /
    • 2010
  • In-flight icing is a critical technical issue for aircraft safety and, in particular, ice accretions on aircraft surfaces can drastically impair aerodynamic performances and control authority. In order to investigate icing effects on the aerodynamic characteristics of KC-100 aircraft, a state-of-the-art CFD code, FENSAP-ICE, was used. A main wing section and full configuration of KC-100 aircraft were considered for the icing analysis. Also, shapes of iced area were calculated for the design of anti-/de-icing devices. The iced areas around leading edge of main wing and horizontal tail wing were observed maximum 7.07% and 11.2% of the chord length of wing section, respectively. In case of wind shield, 16.7% of its area turned out to be covered by ice. The lift of KC-100 aircraft were decreased to 64.3%, while the drag was increased to 55.2%.

NUMERICAL ANALYSIS OF THERMAL FLOW OF CABIN INTERIOR AND DE-ICING ON AUTOMOBILE GLASS (자동차 내부 열유동해석 및 전방유리면의 해빙 전산해석)

  • Song D. W.;Park W. G.;Jang K. L.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.75-80
    • /
    • 2005
  • The present work was undertaken to numerically analyze the defrosting phenomena of windshield glass. In order to analysis the phase change from frost to water on windshield glass by discharging hot air from a defroster nozzle, the flow and the temperature field of the cabin interior, the heat transfer through the windshield glass, and the phase change of frost should be solve simultaneously. In the present work, the flow field was obtained by solving 3-D incompressible Navier-Stokes equations, and the temperature field was computed from the incompressible energy equation. The phase change process was solved by the enthalpy method. For the code validation, the temperature and the phase change of the driven cavity were calculated. The calculation showed a good agreement with other numerical results. Then, the present code was applied to the defrosting problem of a real automobile, and a good agreement with the experimental data was also obtained.

  • PDF

Demonstration of 10kw Wind Turbine System at the King Sejong Station (극한환경에서의 소형풍력발전 실증운전)

  • Kim, Seok-Woo;Kyong, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.25-30
    • /
    • 2006
  • 10kW wind turbine has been successfully commissioned at the King Sejong station in April, 2006. The wind turbine installed is a part of the R&D program for developing a solid wind/diesel hybrid power control system for a remote area such as Antarctica. At the same time, the current research aims to develop an anti-icing and de-icing technologies for a small wind turbine rated under 50kW. Since its commissioning, the turbine has generated about 500kWh for 47days without any system faults. Although sufficient data have not been obtained yet, any trouble has not occurred in the wind/diesel hybrid system based on the current analysis. Concerning on the environmental impact by the wind turbine operation, the turbine is installed within the station boundary in order to meet the Madrid protocol. Therefore, wind turbine operation meets the international requirements for preservation of antarctic ecosystem.

Prediction of Time to Corrosion for Concrete Bridge Decks Exposed to De-Icing Chemicals (제빙화학제 살포로 인한 콘크리트 교량 바닥판의 철근부식 시작시기의 예측)

  • Lee, Chang-Soo;Yoon, In-Seok;Park, Jong-Hyok
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.606-614
    • /
    • 2003
  • The major cause of deterioration for the concrete bridge decks exposed to de-icing chemicals would be chloride-induced reinforcement corrosion. Thus, in this paper, in order to predict time to corrosion for concrete bridge decks in the urban area, chloride concentration was measured with depth from the surface. A frequency analysis on surface chloride concentration and chloride diffusion coefficient of concrete bridge deck equals 0.192, 29.828 in the scale parameter and 7.899, 1.983 in the shape parameter of gamma distribution. The average value of surface chloride concentration equals 1.5 kg/㎥ and condenses from 1 to 2 kg/㎥ in the level of probability 70%. From the probabilistic results, it is confirmed that 26mm of minimum cover depth in order to target 20 years over is calculated. The countermeasure strategy to extend the service life of concrete bridge deck exposed to de-icing chemicals would be an effective method to increase cover depth and to place high performance concrete, which could lead to reduce the chloride diffusion coefficient and distribution range.

Numerical Study on the Performance Assessment for Defrost and De-Icing Modes (승용차의 제상 및 성에 제거 성능 평가를 위한 수치해석적 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.161-168
    • /
    • 2011
  • The heating, ventilating, air conditioning (HVAC) system is a very important part of an automotive vehicle: it controls the microclimate inside the passenger's compartment and removes the frost or mist that is produced in cold/rainy weather. In this study, the numerical analysis of the defrost duct in an HVAC system and the de-icing pattern is carried out using commercial CFX-code. The mass flow distribution and flow structure at the outlet of the defrost duct satisfied the duct design specification. For analyzing the de-icing pattern, additional grid generation of solid domain of ice and glass is pre-defined for conductive heat transfer. The flow structure near the windshield, streakline, and temperature fields clearly indicate that the de-icing capacity of the given defrost duct configuration is excellent and that it can be operated in a stable manner. In this paper, the unsteady changes in temperature, water volume fraction, and static enthalpy at four monitoring points are discussed.

Investigation on Translocation of De-icing Salts influenced by the Intensity of Foliar Damage of Roadside Trees in Chung-ju City (충주시 가로수의 황변정도에 따른 토양 내 제설제 성분의 흡수이행성 평가)

  • Kim, Jae-Young;Kim, Won-Tae;Yoon, Young-Han;Ju, Jin-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2018
  • Use of de-icing salts results in accumulation of high concentrations of ions on roadside soils and tree. The purpose of this study isto determine translocation of seasonal impact of exchangeable cations originating from de-icing salt on roadside surface soil-plant influenced by the intensity of foliar damage (NY = 0-25%, SY = 26-50%, CY = 51-75%) of trees. This paper investigated the concentration of four exchangeable cations ($K^+$, $Ca^{2+}$, $Na^+$, and $Mg^{2+}$) on the roadside surface soil. The tree (Ginko biloba) samples were collected from the Konkuk and Judeok intersections in Chung-ju city. The sequential extraction procedure was applied to 120 soil samples of the soilsurface and 30 tree samples. Four cation exchange ions were determined by ICP-OES. The content of four exchangeable cations present on roadside soil was found to be the lowest in NY but highest in CY from tree pits in the order of NY < SY < CY. Especially, the results were apparent during spring time compared to other seasons. Soil collected from tree pits had the highest concentration of $Ca^{2+}$ possibly due to a higher volume of traffic on those streetsresulting in splashing of more calcium chloride ($CaCl_2$). The analysis of three exchangeable cations ($K^+$, $Mg^{2+}$, and $Na^+$) in the tree leaves revealed higher levels than roadside surface soil when foliar damage ratio increased in the order of NY < SY < CY in summer. In addition, a strong positive linear relationship was observed between the concentration of exchangeable cations in soil and trees. It is hypothesized that the results of this study can be a valuable baseline for managing de-icing salt on roadside soil and trees, in order to mitigate the salt stress that can damage the roadside soil and trees.

Analysis of Chloride Ion Penetration Properties into Concrete on Road Facilities Depending on the Deterioration Environments (국도 상 도로시설물 대상 열화환경 조건 별 콘크리트 염화물 침투 특성 분석)

  • Min, Jiyoung;Lee, Jong-Suk;Lee, Tack-gon;Cha, Ki-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.102-113
    • /
    • 2021
  • The deterioration environments caused by de-icing salt and airborne chlorides in the seashore, evaluated in the "Detailed guideline for safety and management practice of facilities (performance evaluation)", were reviewed in terms of penetrated chlorides into concrete on various road facilities. Target concrete structures, in this study, were 4 concrete barriers in Gangwon area, 3 concrete barriers and 1 retaining wall in Busan area, and 4 bridges in Gangwon-do, Seoul, Gyeonggi-do, and Busan. The deterioration environments were classified into three categories: direct and indirect de-icing salt attack, and airborne salt attack depending on the distance to seashore and the height of pier, and the penetrated chlorides in to concrete were analyzed. The results showed that (1) the regional deterioration environments were clearly classified by de-icing salt sprayed days (snowfall days), (2) the penetrated chlorides increased significantly when leakage occurred through slabs or expansion joints, and (3) the airborne chlorides affected to a height of 20 m concrete in the seashore, Busan. From these, it could be confirmed that the chloride ion penetration properties depend on the exposed aging environment, member location and height, and deterioration status, even on the same structure, so the selection of target members and location is very important in the inspection and maintenance. If the database of penetrated chlorides properties in various deterioration environments is constructed, it is expected that the proactive durability management on concrete structures will be possible in the field.

Design Verification of ECS Condenser Icing Protection System by Flight Test of T-50 Advanced Trainer (T-50 비행시험을 통한 환경제어계통 콘덴서 빙결방지 설계 검증)

  • Nam, Yong-Seog;Kim, Yeonhi;Song, Seok-Bong;Seo, Dong-Yun;Son, Won-Ik;Park, Sung-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.3
    • /
    • pp.40-44
    • /
    • 2008
  • T-50 ECS(environment control system) was designed to have freezing protection for the condenser. However during the ground and flight test, the freezing problem was occurred. This paper deals with the analysis of the freezing problem and introduces anti-freezing design using ADI(Active De-Icing) logic to solve the condenser freezing problem of T-50 ECS

  • PDF

Theoretical Study on Snow Melting Process on Porous Pavement System by using Heat and Mass Transfer (열전달 및 물질전달을 이용한 공극 발열도로에서의 융설 해석에 대한 이론적 연구)

  • Yun, Taeyoung
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.1-10
    • /
    • 2015
  • PURPOSES : A finite difference model considering snow melting process on porous asphalt pavement was derived on the basis of heat transfer and mass transfer theories. The derived model can be applied to predict the region where black-ice develops, as well as to predict temperature profile of pavement systems where a de-icing system is installed. In addition, the model can be used to determined the minimum energy required to melt the ice formed on the pavement. METHODS : The snow on the porous asphalt pavement, whose porosity must be considered in thermal analysis, is divided into several layers such as dry snow layer, saturated snow layer, water+pavement surface, pavement surface, and sublayer. The mass balance and heat balance equations are derived to describe conductive, convective, radiative, and latent transfer of heat and mass in each layer. The finite differential method is used to implement the derived equations, boundary conditions, and the testing method to determine the thermal properties are suggested for each layer. RESULTS: The finite differential equations that describe the icing and deicing on pavements are derived, and we have presented them in our work. The framework to develop a temperature-forecasting model is successfully created. CONCLUSIONS : We conclude by successfully creating framework for the finite difference model based on the heat and mass transfer theories. To complete implementation, laboratory tests required to be performed.

An Experimental Study on Evaluation Methods for Scaling Resistance of Cement Concrete Pavement (시멘트 콘크리트 포장의 스케일링 저항성 평가방법에 관한 실험적 연구)

  • Lee, Hyeon-Gi;Oh, Hong-Seob;Sim, Jong-Sung;Shim, Jae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • In cold-climate regions, deicing agents is used for smooth traffic on the road due to freezing and snowdrift in winter. The use of de-icing salts has resulted in the accelerated scaling damage of concrete with salt damage under freezing and thawing condition. Scaling is the deterioration of concrete where in the paste-mortar structure delaminates in flakes from the surface of the concrete. Due to such damage, concrete pavement causes various problems such as early deterioration according to the decrease in the thickness of cover concrete and user's stability issues. Accordingly, various tests and evaluation methods have been suggested in order to evaluate these phenomena in other countries. However, there have been no regulations for the evaluation method in South Korea, and related studies are also very rare. Therefore, in this study, the evaluation methods proposed by each institution and country were investigated and the experiments were performed according to each regulation, followed by the comparison and analysis of the results. Furthermore, this study aims to suggest the optimized experimental method adopted to domestic field through the discussion of such experimental methods and results.