• 제목/요약/키워드: De-icing

검색결과 87건 처리시간 0.021초

전차선로 해빙시스템의 온도특성 (Temperature Analysis of the De-icing System for Overhead Contact Wire)

  • 고병훈;박영;정호성;권삼영;박현준
    • 한국전기전자재료학회논문지
    • /
    • 제20권11호
    • /
    • pp.1004-1008
    • /
    • 2007
  • The ice coats are built on 25 kV overhead contact wire when the temperature is lower than $0^{\circ}C$. It generates shockwaves at the mechanical interface of the collecting strips of the pantograph and the contact wire. The de-icing processes should be performed to avoid shockwaves which are generated by a pulsed high-voltage arc discharge. This paper presents temperature analysis of the de-icing effects which could be applied to the overhead contact wire of railways using Joule heat. The results show that 350 A is the proper current for $0^{\circ}C$ conductor according to environmental condition such as velocity of air stream, ambient temperature and moisture.

대기 결빙 조건에서의 전기열 방식 결빙보호 시스템에 관한 전산해석 (COMPUTATIONAL ANALYSIS OF AN ELECTRO-THERMAL ICE PROTECTION SYSTEM IN ATMOSPHERIC ICING CONDITIONS)

  • 프린스 라즈;명노신
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.1-9
    • /
    • 2016
  • Atmospheric icing may have significant effects not only on safety of aircraft in air, but also on performance of wind turbine and power networks on ground. Thus, ice protection measure should be developed to protect these systems from icing hazards. A very efficient method is the electro-thermal de-icing based on a process by which ice accretion is melted and blown away through aerodynamic forces. In this computational study, a state-of-the-art icing code, FENSAP-ICE, was used for the analysis of electro thermal de-icing system. Computational results including detailed conjugate heat transfer analysis were then validated with experimental data. Further, the computational model was applied to the DU21 airfoil section of NREL 5MW wind turbine with calculated heater parameters.

교통량 및 제설제 사용량에 따른 고속도로 포장의 공용수명 분석 (A Study to Analyze Service Life of Expressway Pavement according to Traffic Volumes and De-icing Chemicals)

  • 김찬우;안수한;박희영;이정훈;정철기
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.35-41
    • /
    • 2015
  • PURPOSES : The purpose of this study is to analyze the service life of expressway pavement based on both traffic volumes and use of deicing chemicals. METHODS : A database was built using expressway rehabilitation history information from over the last decade. In order to estimate the service life of expressway pavement, various analysis methods were considered, and a decision was made to perform analysis using a method based on an accumulated rehabilitation ratio. The service life of expressway pavement was then analyzed by classifying the scale of traffic volume and extent of de-icing chemicals used. RESULTS : The service life of PMA and SMA ranged from 7.8 to 10.6 years and from 9.9 to 12.0 years, respectively. The service life of JCP ranged from 16.0 to 22.2 years, and the service life of CRCP was 33.5 years on average. Results of assessing service life according to traffic volumes and de-icing chemicals showed that the lower the traffic volumes were, the greater the service life of PMA and JCP, and the less that de-icing chemicals were applied, the greater the service life of JCP. CONCLUSIONS : The dependence of expressway pavement service life on traffic volumes and de-icing chemicals makes it possible to apply LCCA for regional maintenance plans and cost-effective selection of expressway pavement type.

제설제에 노출된 서울시내 도로 시설물의 열화 환경 분석 (Evaluation on De-Icing Salts Laden Environment of Road in Seoul)

  • 윤인석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2022
  • 제설제는 동절기 도로 위의 눈을 녹이기 위하여 사용되고 있으나, 서울과 같은 대도시에서 교통이 밀집한 도로 시설물의 열화를 촉진시키는 주요 요인 중의 하나이다. 도로 시설물의 합리적인 유지관리 전략을 수립하기 위하여 제설제에 노출된 도로 시설물의 환경분석이 필요하다. 본 연구는 서울시의 적설량 및 사용된 제설제량을 토대로 외래 염소농도를 계산하였다. 평균 표면 염소이온량을 구하고자 서울시의 5년간 기후환경 및 제설제 사용량을 이용하였으며, 주간선 및 보조간선율 17.5 ~ 30%, 제설제 노출 유효면적율 50 ~ 80% 수준에서 검토하였는데, 농축 속도는 0.073~ 0.077%/년, 최대 표면 염소이온량은 콘크리트 중량대비 2.2 ~ 2.31% 수준이었다. 본 연구결과는 염소이온 프로파일의 예측 또는 콘크리트 구체의 화학적 부식정도 등으로 종합적인 유지관리 대책을 수립하는데 활용될 수 있을 것으로 기대된다.

해빙 시스템을 이용한 전차선 온도 특성에 관한 연구 (Temperature Analysis of Overhead Contact line Using De-icing System)

  • 박영;권삼영;정호성;박현준;조용현;김주락;안병립;원우식;이주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.601-602
    • /
    • 2005
  • In the cold and temperate regions of Korea the icing and ice coats on 25 kV overhead contact wire during winter is a very serious problem. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should be performed just before train operation to avoid the formation of another ice layer. This paper presents temperature analysis of the de-icing system which could be applied to the overhead contact wire of railways.

  • PDF

소수성 처리된 나노다공성 알루미늄 양극산화피막의 제빙 (De-icing of the hydrophobic treated nanoporous anodic aluminum oxide layer)

  • 신예지;김진휘;신동민;문형석;이정훈
    • 한국표면공학회지
    • /
    • 제54권5호
    • /
    • pp.222-229
    • /
    • 2021
  • Icing causes various serious problems, where water vapor or water droplets adhere at cold conditions. Therefore, understanding of ice adhesion on solid surface and technology to reduce de-icing force are essential for surface finishing of metallic materials used in extreme environments and aircrafts. In this study, we controlled wettability of aluminum alloy using anodic oxidation, hydrophobic coating and lubricant-impregnation. In addition, surface porosity of anodized oxide layer was controlled to realize superhydrophilicity and superhydrophobicity. Then, de-icing force on these surfaces with a wide range of wettability and mobility of water was measured. The results show that the enhanced wettability of hydrophilic surface causes strong adhesion of ice. The hydrophobic coating on the nanoporous anodic oxide layer reduces the adhesion of ice, but the volume expansion of water during the freezing diminishes the effect. The lubricant-impregnated surface shows an extremely low adhesion of ice, since the lubricant inhibits the direct contact between ice and solid surface.

고속철도차량용 제빙액으로의 적용가능물질에 대한 융빙성능 평가 (Ice Melting Capacity Evaluation of Applicable Materials of De-icing Fluid for High Speed Railway Rolling Stock)

  • 박경원;이준구;이홍기
    • 공업화학
    • /
    • 제30권3호
    • /
    • pp.384-388
    • /
    • 2019
  • 동절기 고속철도차량 하부 및 대차부에 부착된 설빙이 차량 운행 시 도상자갈구간(침목이 받는 차량 하중 전달 및 침목 고정을 위한 자갈 구간)에서 고속으로 낙하하여 자갈을 비산시켜 이로 인한 철도차량 구조물 및 시설물의 피해가 보고되고 있으며, 이는 고속철도 개통 이후 지속되고 있다. 이러한 문제점 해결을 위해 자갈의 비산을 방지하는 네트, 인력 제빙, 이동식 열풍기 등을 사용하고 있으나 효율성이 떨어진다. 기존보다 효율적인 제빙을 위해 화학적 제빙액에 대한 연구가 진행되고 있으며, 본 연구에서는 화학적 제빙액으로 사용되는 물질들의 융빙성능, 동점도, 증발성 등을 평가하여 고속철도차량 제빙용으로 최적의 물질을 찾고자 한다. 평가 물질로는 유기산염류 4종(개미산나트륨, 초산나트륨, 개미산칼륨, 초산칼륨)과 알코올류 2종(프로필렌글리콜, 글리세롤)을 대상으로 하였다. 이때, 실내 평가에서는 개미산칼륨, 초산칼륨, 프로필렌글리콜이 유사한 융빙성능을 보였으나, 모사 살포 시스템을 이용한 융빙성능 결과, 프로필렌글리콜이 가장 우수한 성능을 보였다. 이는 프로필렌글리콜의 동점도가 2.989029 St로 다른 물질 대비 높아 얼음에서 보다 오래 체류하여 제빙하기 때문이다. 또한, 개미산칼륨과 초산칼륨은 결정이 석출되어 차량외관에 악영향을 미치므로 사용에 어려움이 있다. 본 연구를 통해 프로필렌글리콜이 고속철도차량용 제빙액으로 최적의 물질임을 확인하였다.

융빙제에 의한 콘크리트의 내구성능 저하에 관한 실험적 연구 (An Experimental Study on the Deterioration of Concrete Due to De-icing Salts)

  • 고경택;류금성;이종석;김도겸;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.973-978
    • /
    • 2001
  • In clod weather regions, a strong seasonal wind brings sea salts to the land. In addition to it, recently, the spreading amount of de-icing salts has increased numerously for the purpose of removing snow and ice. Thus the salts environment around concrete structures becomes so severe that various damages of concrete due to applied salts will be brought up. It is briskly carried out study on effects of do-icing salts on concrete in America, Japan, European countries. However, there are not test method for the deterioration of concrete subjected to both freezing-thawing and chloride attack in Korea. In this study, we conduct on test for the compound deterioration subjected to both freezing-thawing and chloride attack, in order to investigate effects of de-icing salts on the deterioration of concrete.

  • PDF

전차선 해빙시스템의 온도 상승효과 (Analysis of Temperature on Overhead Contact Line Using De-icing System)

  • 박영;권삼영;정호성;조용현;박현준;이기원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.724-729
    • /
    • 2005
  • Winter weather condition can cause icing and ice coats on 25 kV overhead contact wire. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should he performed just before train operation to avoid the formation of another ice layer. Thus, the work in this paper is investigation and analysis of de-icing system which could be applied to the electric car line of railways.

  • PDF

해빙시스템을 위한 기후변화에 따른 전차선 온도특성에 관한 연구 (A Study on the Temperature Feature of Electric Car Line by the Climatic Change for the De-icing System)

  • 정명섭;김용;이병송;권삼영;정호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.305-307
    • /
    • 2005
  • In the cold and temperate regions of Korea the icing and ice coats on 25[kV] electric car line during winter is a very serious problem. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should be performed just before train operation to avoid the formation of another ice layer. This paper presents temperature analysis of the de-icing system which could be applied to the electric car line of railways.

  • PDF