• 제목/요약/키워드: Dc-link current

검색결과 511건 처리시간 0.032초

단일 DC-Link 전류 계측만을 이용한 BLDC 구동시스템의 디지털 전류 제어 (A Digital Current Control using Single DC-Link Current Sensing of BLDC Actuation Systems)

  • 한봉수
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.72-80
    • /
    • 2019
  • In this paper, we propose a digital DC-Link current control approach for BLDC actuation systems. The proposed approach consists of the following two components: first, DC-Link current measurement with sampling instances synchronized with PWM frequency, and second, current control using single DC-Link current rather than three phases current of a motor. The proposed method proved its performance through experiments and simulation. The results showed that the control performance are increased compared with the BLDC actuation system which does not use current control.

An Interleaving Scheme for DC-link Current Ripple Reduction in Parallel-Connected Generator Systems

  • Jeong, Min-Gyo;Shin, Hye Ung;Baek, Ju-Won;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1004-1013
    • /
    • 2017
  • This paper presents an interleaving scheme for parallel-connected power systems to reduce the DC-link current ripple. A paralleled generator system generates current ripple by the Pulse Width Modulation (PWM) of each generator side converter. The current ripple in the DC-link degrades the efficiency of the whole generator system and decreases the lifetime of the DC-link capacitors. To mitigate these issues, the expression of the DC-link current is derived by a double-integral Fourier analysis while considering the modulation schemes. Optimized interleaving angles for the parallel generator system are obtained based on an analysis to minimize the dominant current harmonics component. Finally, the proposed interleaving scheme reduces the RMS value of the DC-link current ripple. Simulation and experimental results verify the effectiveness of the proposed interleaving scheme.

하이브리드 전기자동차용 양방향 DC-DC Converter제어 알고리즘 개발 (Development of the Bidirectinal DC-DC Converter Control Algorithm for Hybrid Electric Vehicles)

  • 오두용;구본관;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.346-349
    • /
    • 2004
  • The design of DC-DC converters for power electronic interfaces in power management systems for Hybrid Electric Vehicle (HEV) is a very challenging task. In this paper, the considered topology is the hi-directional buck-boost converter and inverter system. If we make the converter side DC link current the same as the inverter side DC link current in a converter-inverter system, no current will flow through the BC link capacitor and as a result, no DC link voltage variation occurs. This leads to the possibility of reducing small th size of DC link capacitors which are expensive, bulky. Therefore we propose the converter current controller which can manage to match inverter and converter current at the DC link.

  • PDF

다상/다단 부스트 컨버터의 DC-Link 리플 전류 분석 (A Study on DC-Link Current Ripple of Multi-Phase/Multi-Stage Boost Converter)

  • 김승민;김동희
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.59-67
    • /
    • 2023
  • This paper explores the variation of DC-Link current ripple analysis in terms of duty cycle and phase angle of Multi-phase/Multi-stage boost converter. A 2-Stage/1-Stage boost converter DC-Link current is used to determine the difference between the 1st stage diode current and the 2nd stage inductor current. Each stage boost converter diode and inductor current is subordinate to the phase angle and duty cycle. The magnitude of the ripple current is variable according to phase angle and duty cycle. The analysis results are verified by variation of DC-Link current ripple using a 1kW typical 2-stage/1-stage boost converter.

전류 리플을 이용한 직류단 캐패시터의 용량 선정 기법에 관한 연구 (A Study on Capacitance Selection Method of DC-link Capacitor Using Current Ripple)

  • 김용휴;이병훈;황선환
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.47-53
    • /
    • 2022
  • This paper proposes a method for selecting the capacitance of DC-link capacitors of inverters. In general, the DC-link capacitance of the inverter system must be considered for DC-link voltage, ripple current, switching frequency, ripple voltage, and pulse-width modulation techniques. Therefore, the appropriate capacitance can be determined by finding the rms and peak values of the ripple current of the capacitor. In this paper, the process of extracting the ripple current of DC-link capacitor is described in detail. In addition, the simple method for finding DC-link capacitor capacitance using the result value is presented through the simulations.

치과 핸드피스용 고속 PMSM의 정현파 구동을 위한 인버터 직류 링크전압 제어기법 (DC link voltage control method in the sinusoidal current drive system for dental hand-piece PMSM)

  • 전금상;박상욱;박재성;김상희;안희욱
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.16-21
    • /
    • 2013
  • This paper presents a DC link voltage control method to reduce the ripple current and the switching loss in the sinusoidal current drive system for the wide-speed range PMSM. The DC link voltage of the three phase inverter in the sinusoidal current drive system is designed by the back-EMF voltage at maximum speed of the PMSM. In general, the drive systems have used the constant DC link voltage without reference to the motor speed. The current ripple causes hysteresis loss and makes noise. In addition, the switching loss on the inverter increases in proportion to the rise in the DC link voltage. In this paper, we propose the variable DC link voltage control method to reduce the current ripple in the PMSM drive system. We show reduction effect of the current repple and the switching loss through simulation results.

DC Link단 단일 전류센서에 의한 브러시리스 직류 전동기의 토크 리플 저감 (Torque Ripple Reduction of BLDG Motors Using Single DC-Link Currant Sensor)

  • 백대진;원창희;이교범;최익;송중호;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.974-976
    • /
    • 2001
  • This paper presents a method to reduce commutation torque ripples occurred during commutation in brushless do motor drives using a single DC-link current sensor. In brushless dc motor drives with a single dc current sensor instead of 3-phase line current sensors, it is noted that dc-link current sensor cannot give any information corresponding to the motor currents during line current commutation intervals. A new technique to resolve such a problem is dealt with based on a deadbeat current control in which motor armature voltage command is computed from a dc-link current reference, an actual current and counter emf voltage. The simulation results show that the proposed method reduces the torque ripple significantly.

  • PDF

Minimization of DC-Link Capacitance for NPC Three-level PWM Converters

  • Alemi, Payam;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.370-371
    • /
    • 2011
  • This paper presents a control algorithm that minimizes the DC-link capacitance by decreasing the capacitor current. The capacitor current can be nullified by a feedback compensation term which is calculated from the power balance in the AC/DC converter. As a result, voltage variation in the DC-link is reduced further, which makes a large reduction in the size of DC-link capacitors which are expensive and have limitations in life time. Simulations are performed with two 80uF DC-link capacitors, which can be replaced by film capacitors.

  • PDF

동력의지를 위한 BLDCM 구동 시스템 및 상전류 추정 기법 (A Brushless DC Motor Drive System and Phase Current Estimation Method For Active Knee Prothesis)

  • 남기준;최연범;정두희
    • 재활복지공학회논문지
    • /
    • 제7권2호
    • /
    • pp.7-12
    • /
    • 2013
  • 본 논문에서는 동력의지를 위한 브러쉬리스 DC 모터 구동 시스템과 DC 링크단의 전류를 이용하여 상전류를 추정하는 기법을 제안한다. 토크제어를 위해서는 전류 측정이 매우 중요하며 전류 측정 시 스위칭 노이즈를 최소화하기 위해 전류 센싱 시점은 스위칭 전압 명령에 동기화 되어야 한다. 저가의 시스템, 공간의 절약 그리고 제어의 단순화하기 위해 DC 링크단 전류를 사용한 제어를 실시하였다. 또한 환류 다이오드를 통해 흐르는 전류에서 발생하는 DC 링크단 전류와 상전류간의 오차를 줄이기 위해 Analog MUX를 이용한 상전류 추정방법을 사용하였다. 실험 결과를 통해 제안한 시스템의 유효성을 검증하였다.

  • PDF

직류링크전류를 기반으로 한 SRM 3상전류 추정법 (3-Phase Current Estimation of SRM Based on DC-Link Current)

  • 김주진;최재호;김태웅
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.307-312
    • /
    • 2006
  • 본 논문에서는 직류링크전류를 기반으로 SRM의 상전류를 추정하였고 이를 이용한 SRM 에 대한 속도제어법을 제안하였다. 또한 직류링크전류검출회로를 제안하여 전류검출분해능을 높일 수 있었으며 오프셋에 의한 영향을 최소화시킬 수 있는 장점을 가지고 있다. 상전류 정보를 이용한 SRM 구동방식과 직류링크전류정보를 이용한 SRM 구동방식을 실제실험을 통하여 비교함으로서 본 논문에서 제안한 상전류 추정알고리즘과 이에 관련된 직류링크전류 검출회로에 대한 유효성이 검증되었고 직류링크전류를 이용한 SRM 속도제어시스템은 속도응답이 3 상 전류정보를 이용한 시스템만큼 빠른 응답특성이 있음을 확인하였다.