Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

A Novel Droop Control Method to Minimize Distribution Loss in DC Microgrid (DC 마이크로그리드의 배전 손실 최소화를 위한 새로운 드룹 제어 기법)

  • Kim, Seok-Woong;Choi, See-Young;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.371-372
    • /
    • 2015
  • Dc microgrid has the advantage of high efficiency as compared to the ac system. Droop method has been realized to suppress the current mismatching among the distributed sources. However, this method involves distribution loss due to the line impedance. In this paper, a novel droop method is proposed to minimize the distribution loss as well as the voltage deviation by adjusting the droop coefficient. The proposed droop method is verified by using the simulation based on PSCAD/EMTDC.

  • PDF

Fabrication of an HTS DC SQUID Electronic Gradiometer and it's application in NDE system (고온 초전도 Electronic Gradiometer의 제작과 NDE system 에의 응용)

  • Kim, Jin-Young;Han, Sung-Gun;Kang, Joon-Hee;Lee, Eun-Hong;Song, I-Hun
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.120-123
    • /
    • 1999
  • We designed and constructed a non-destructive evaluation system using an HTS DC SQUID electronic gradiometer. Our DC SQUID electronic gradiometer is composed of two DC SQUID magnetometers. The system included a non-magnetic stainless steel cryostat and a set of coaxial exciting coils, which were used to induce an eddy current in the test material. We also have calculated the eddy current density produced by an exciting coil in any direction of the testing object. We could compute the eddy current density distribution in 3D. The SQUIDs were computer controlled and the output data from the electronic gradiometer was obtained by using a Labview software.

  • PDF

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

A Lecture Note on PU Method thru Calculation of a Simple DC Circuit and Voltage/Fault Analysis of Industrial Power Systems using Actual Data (PU법에 의한 DC 회로계산 및 실계통 데이터를 이용한 전압강하/고장계산 방법)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.45-54
    • /
    • 2014
  • This paper presents a lecture note of pu method for power system analysis. The author tries to help students in class better understand the fundamental of pu calculation using a very simple DC circuit. And a voltage drop calculation by pu method for a distribution system is given to help understand the importance of the vector reference in AC circuit analysis. A short current calculation by pu method for a power system with a generator, transformer and transmission line is also presented to show how pu calculation can be applied to real power systems, in which all the data are the ones currently being used by KEPCO and other industrial sites.

Integrated Operation of DC Distribution System for Building Application (빌딩에 적용되는 DC 배전 시스템의 통합 운전)

  • Han, Dong-Woo;Shin, Soo-Cheol;Lee, Hee-Jun;Won, Chung-Yuen;Lee, Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.57-58
    • /
    • 2013
  • 본 논문에서는 빌딩과 같은 건축물에 적용될 DC 배전 시스템의 통합 운전에 대하여 제안 및 분석을 하였다. 제안하는 DC 배전 시스템은 AC/DC 전력 변환 모듈 2개와 하나의 ESS (Energy Storage System) 모듈이 병렬로 연결 되어있으며, ESS와 부하의 상태에 따라 적합한 운전 모드로 동작 하게 된다. ESS와 부하의 상태는 시뮬레이션을 통해 모의하였으며, 제안된 시스템은 각 상황에 대응하는 제어가 원활히 이루어지는 것을 검증하였다.

  • PDF

Maximum Power Point Tracking Control for a Grid-Tie Photovoltaic Inverter (계통 연계형 태양광 인버터에서 최대 출력 점 추적 제어)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.72-79
    • /
    • 2009
  • Solar energy is desirable due to its renewable and pollution-free properties. In order to utilize the present utility grid infrastructure for power transmission and distribution, a do-dc boost converter and grid connected dc-to-ac inverters are needed for solar power generation. The dc-dc boost converter allows the PV system to operate at high do-link voltage. The single-phase inverter provides the necessary voltage and frequency for interconnection to the grid. In this paper, first, current loop transfer function of a single-phase grid-tie inverter has been systematically derived Second the MPPT of conductance increment method at converter side is proposed to supply the maximum power to the inverter side. Simulation results are shown to access the performance of PV system and its behaviour at the interconnection point.

A Study on the Energy Saving Strategy in Electric Railway System (직류 전기철도 에너지 절감방안 연구)

  • Choi Byung-Woon;Chang Sang-Hoon;Kim Hak-Ryun
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.676-681
    • /
    • 2005
  • The regenerative braked cars are being introduced in DC electric railway for energy saving. There has been a recent tendency for DC traction substation with regenerative inverter to increase in number. This is strongly related to the desire for effective utilization of electric power regenerated by DC electric cars and to the aim ensuring stable operation of regenerative braking system. The regenerative inverters DC power feed back from a generative car into AC power at a substation and supplies it to distribution lines. This paper suggest the result of characteristic analysis and capacity simulation. economical analysis in the regenerative inverter system.

  • PDF

A Novel DC Bus Voltage Balancing of Cascaded H-Bridge Converters in D-SSSC Application

  • Saradarzadeh, Mehdi;Farhangi, Shahrokh;Schanen, Jean-Luc;Frey, David;Jeannin, Pierre-Olivier
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.567-577
    • /
    • 2012
  • This paper introduces a new scheme to balance the DC bus voltages of a cascaded H-bridge converter which is used as a Distribution Static Synchronous Series Compensator (D-SSSC) in electrical distribution network. The aim of D-SSSC is to control the power flow between two feeders from different substations. As a result of different cell losses and capacitors tolerance the cells DC bus voltage can deviate from their reference values. In the proposed scheme, by individually modifying the reference PWM signal for each cell, an effective balancing procedure is derived. The new balancing procedure needs only the line current sign and is independent of the main control strategy, which controls the total DC bus voltages of cascaded H-bridge. The effect of modulation index variation on the capacitor voltage is analytically derived for the proposed strategy. The proposed method takes advantages of phase shift carrier based modulation and can be applied for a cascaded H-bridge with any number of cells. Also the system is immune to loss of one cell and the presented procedure can keep balancing between the remaining cells. Simulation studies and experimental results validate the effectiveness of the proposed method in the balancing of DC bus voltages.

Input-Constrained Current Controller for DC/DC Boost Converter

  • Choi, Woo Jin;Kim, Seok-Kyoon;Kim, Juyong;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2016-2023
    • /
    • 2016
  • This paper presents a simple input-constrained current controller for a DC/DC boost converter with stability analysis that considers the nonlinearity of the converter model. The proposed controller is designed to satisfy the inherent input constraints of the converter under a physically reasonable assumption, which is the first contribution of this paper. The second contribution is providing a rigorous proof of the proposed control law, which keeps the closed-loop system along with the internal dynamics stable. The performance of the proposed controller is demonstrated through an experiment employing a 20-kW DC/DC boost converter.