• Title/Summary/Keyword: Dc-Link Voltage Ripple

Search Result 126, Processing Time 0.034 seconds

Analytic Model of Four-switch Inverter-fed Driving System for Wye or Delta-connected Motor with Current Ripple Reduction Scheme

  • Lee, Dong-Myung;Jung, Jin-Woo;Heo, Seo Weon;Kim, Tae Heoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 2016
  • This paper proposes an analytic model for four-switch inverter (FSI)-driven wye (Y) or delta (Δ)-connected motors with a current ripple reduction algorithm. FSIs employ four switches in controlling three-phase load instead of using six switches. They have split dc-link stage, and due to this inherent structure there exists the voltage difference between upper and lower capacitors, which results in distortion of the inverter output voltage. To study characteristics of FSIs, this paper presents an advanced simulation models of FSI-driven control system for 3-phase motor that can has a wire connection either Y or Δ. In addition, this paper introduces a current ripple reduction scheme that mitigates degradation of control performance due to the voltage difference between the dc-link capacitors. The validity of the proposed method and the analytic model is verified by simulations and experiments carried out with 1-HP induction machine with Y or Δ-connection

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Suppression method for current oscillation of V/F controlled high speed induction motor (V/F 제어 고속 유도전동기의 전류 진동 억제 방법)

  • Lee, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.150-151
    • /
    • 2017
  • This paper deals with the suppression of subharmonic current oscillation of V/F controlled high speed induction motor drive in turbo blower applications. High speed induction motor has a relatively low stator impedance for high speed operation and therefore the dc link voltage ripple may result in subharmonic current oscillation at the steady state in high speed operation. This paper shows that the subharmonic oscillation is caused by the dc link voltage ripple and also proposes the suppression method, which generates the compensation voltage through the proportional current controller to reduce the subharmonic current oscillation. The simulation and experimental results show that the proposed suppression method reduces the subharmonic current oscillation to the acceptable low level in turbo blower applications.

  • PDF

Optimal Design of Notch Filter in Photovoltaic Inverter (태양광 인버터의 노치 필터 최적 설계)

  • Kim, Yong-Rae;Heo, Cheol-Young;Lee, Young-Kwoun;Choy, Ick;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.81-92
    • /
    • 2019
  • When Photovoltaic inverter is connected to grid and used as PVPCS (Photovoltaic Power Conditioning System), 120 Hz AC ripple occurs at the dc-link capacitor voltage. This AC ripple reduces the efficiency of PVPCS and shortens the lifetime of the capacitor. In this paper, we design a notch filter to remove AC ripple. As a result, the AC voltage ripple was removed from the dc link and the THD of the PVPCS output current with the notch filter was lowered. This notch filter is determined by the damping coefficient, the bandwidth coefficient, and the switching frequency. Among these, the switching frequency determines the switching loss and the size of the LC filter, and the PVPCS with the high switching frequency has a greater efficiency loss due to the switching loss than the efficiency improvement by the notch filter. Therefore, it is important to set the optimum switching frequency in the PVPCS with the notch filter applied. In this paper, THD and switching loss of PVPCS output current with notch filter are calculated through simulation, and cost function to calculate optimum switching frequency through data is proposed.

A Controller for PWM AC/DC Converter Considering Distorted Input Voltage (왜곡된 입력 전압을 고려한 PWM AC/DC 컨버터 제어기)

  • 송홍석;남광희
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.1-8
    • /
    • 1997
  • PWM(Pulse Width Modulation) 컨버터의 제어에 있어서, 입력전압의 왜곡을 고려하지 않을 경우, 시스템의 성능 저하를 초래하게 된다. 본 논문은 왜곡된 3상 입력전압이 PWM 컨버터에 미치는 영향을 분석하고, 성능을 개선하기 위한 제어기를 설계한다. 제안된 방식은 단위 역률을 만족시키면서, THD(Total Harmonic Distortion) 및 DC-link 전압의 저차 ripple을 감소시킨다.

  • PDF

Capacitance Estimation of DC-Link Capacitors of Three-Phase AC/DC/AC PWM Converters using Input Current Injection (입력전류 주입을 이용한 3상 AC/DC/AC PWM 컨버터의 직류링크 커패시터 용량 추정)

  • 이강주;이동춘;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.173-179
    • /
    • 2003
  • In this paper, a novel on-line dc capacitance estimation method for the three-phase PWM converter is proposed. At no load, input current at a low frequency is injected, which causes dc voltage ripple. With the at voltage and current ripple components of the dc side, the capacitance can be calculated. Experimental result shows that the estimation error is less than 2%.

A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters (소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법)

  • In, Hyo-Chul;Kim, Seok-Min;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

Estimation of ESR in the DC-Link Capacitors of AC Motor Drive Systems with a Front-End Diode Rectifier

  • Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.411-418
    • /
    • 2015
  • In this paper, a new method for the online estimation of equivalent series resistances (ESR) of the DC-link capacitors in induction machine (IM) drive systems with a front-end diode rectifier is proposed, where the ESR estimation is conducted during the regenerative operating mode of the induction machine. In the first place, a regulated AC current component is injected into the q-axis current component of the induction machine, which induces the current and voltage ripple components in the DC-link. By processing these AC signals through digital filters, the ESR can be estimated by a recursive least squares (RLS) algorithm. To acquire the AC voltage across the ESR, the DC-link voltage needs to be measured at a double sampling frequency. In addition, the ESR current is simply reconstructed from the stator currents and switching states of the inverter. Experimental results have shown that the estimation error of the ESR is about 1.2%, which is quite acceptable for condition monitoring of the capacitor.

An Improved Control Method for a DFIG in a Wind Turbine under an Unbalanced Grid Voltage Condition

  • Lee, Sol-Bin;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.614-622
    • /
    • 2010
  • This paper presents a control method, which reduces the pulsating torque and DC voltage problems of a doubly fed induction generator (DFIG)-based wind turbine system. To reduce the torque and power ripple, a current control scheme consisting of a proportional integral (PI) controller is presented in a positive synchronously rotating reference frame, which is capable of providing precise current control for a rotor-side converter with separated positive and negative components. The power theory can reduce the oscillation of the DC-link voltage in the grid-side converter. In this paper, the generator model is examined, and simulation results are obtained with a 3 kW DFIG-based wind turbine system to verify the proposed control strategy.

A Novel Input and Output Harmonic Elimination Technique for the Single-Phase PV Inverter Systems with Maximum Power Point Tracking (최대출력추종 제어를 포함한 단상 태양광 인버터를 위한 새로운 입출력 고조파 제거법)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.207-209
    • /
    • 2019
  • This paper proposes a grid-tied photovoltaic (PV) system, consisting of Voltage-fed dual-active-bridge (DAB) dc-dc converter with single phase inverter. The proposed converter allows a small dc-link capacitor, so that system reliability can be improved by replacing electrolytic capacitors with film capacitors. The double line frequency free maximum power point tracking (MPPT) is also realized in the proposed converter by using Ripple Correlation method. First of all, to eliminate the double line frequency ripple which influence the reduction of DC source capacitance, control is developed. Then, a designing of Current control in DQ frame is analyzed and to fulfill the international harmonics standards such as IEEE 519 and P1547, $3^{rd}$ harmonic in the grid is directly compensated by the feedforward terms generated by the PR controller with the grid current in stationary frame to achieve desire Total Harmonic Distortion (THD). 5-kW PV converter and inverter module with a small dc-link film capacitor was built in the laboratory with the proposed control and MPPT algorithm. Experimental results are given to validate the converter performance.

  • PDF