• Title/Summary/Keyword: Dc Distribution

Search Result 597, Processing Time 0.023 seconds

A Study on the Development of a Variable Speed Diesel Generator for DC Distribution (직류배전용 가변속 디젤발전기 개발에 관한 연구)

  • Park, Kido;Kim, Jongsu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 2019
  • In this study, research and a demonstration for applying DC distribution systems to ships as an environmental and energy conservation solution in domestic and foreign countries were actively carried out. In order to apply a generator to a DC distribution system, a variable speed engine was used. Both engine speed and fuel consumption were reduced. In this paper, a DC generator for DC distribution was constructed using a diesel generator, a generator controller, a governor, and an AVR. A system configuration method for a generator, power quality test, and the power characteristics of a variable speed generator were analyzed. The voltage (250 - 440 VAC) and frequency (34 - 60 Hz) of the variable speed generator were set to 60 - 100 % of the rated value, and the engine was set to operate from 1100 - 1800 rpm. It was confirmed that the voltage, current, and frequency of the generator output fluctuated in a stable manner according to the power amount when changing the engine speed of the generator according to the load variation.

Power conversion control for zero emission buildings (탄소제로 빌딩을 위한 전력변환 제어)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

DC Characteristics Analysis of Various AC loads for Hybrid Distribution (하이브리드 급전을 위한 다양한 가정용 교류부하의 직류특성연구)

  • Lee, Young-Jin;Han, Dong-Ha;Choi, Jung-Muk;Jeong, Byong-Hwan;Kim, Dong-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • Recently, the use of DC power increased due to the increased use of digital load. Power factor of input current decrease and input current harmonics increase, and conversion loss which is occurred in the AC / DC converter is a problem to provide the proper DC voltage to the device equipped with an internal AC / DC converter. Hybrid system supplies the AC power and DC power to AC load (motor load and the transformer load) and DC loads (computers, TV, LED fluorescent light) at the same time it supplies the renewable energy and utility energy taken power from Utility to user for improving the efficiency and renewable energy improvements in ease of use. This paper studies DC characteristics of traditional AC load for Hybrid distributions.

Power Decoupled Multi-Port Dual-Active-Bridge Converter Employing Multiple Transformers for DC Distribution Applications (복수의 변압기를 사용하여 독립 전력제어가 가능한 DC 배전용 다중포트 Dual-Active-Bridge 컨버터)

  • Kim, Inhyeok;Sim, Ju-Young;Lee, Jun-Young;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.286-292
    • /
    • 2020
  • This study proposes a power decoupled multi-port dual-active-bridge (DAB) DC-DC converter employing multiple transformers. Conventional multiport DAB DC-DC converters experience a power coupling issue from the use of a single transformer, which essentially requires complex power decoupling control. To solve this issue, a multiport DAB DC-DC converter employing multiple transformers is proposed to decouple output power without additional complex control algorithms. The proposed converter uses multiple transformers that can expand output ports easily. Therefore, transformers and the proposed multi-port DAB converter can be designed simply. In addition, the number of coupling inductors can be reduced in the proposed three-port DAB converter compared with that in conventional multiport DAB converters. The power decoupling characteristics and equivalent circuit of the proposed converter are analyzed using theoretical model approaches. Finally, a 3-kW laboratory prototype is developed to verify the effectiveness of the proposed converter.

Insulation Diagnostics of Power Cables and Application to Real Distribution System (케이블 절연열화진단과 실 계통 적용)

  • Yi, Dong-Young;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

Reactive Power Control of Single-Phase Reactive Power Compensator for Distribution Line (배전선로용 단상 무효전력 보상기의 무효전력제어)

  • Sim, Woosik;Jo, Jongmin;Kim, Youngroc;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.73-78
    • /
    • 2020
  • In this study, a novel reactive power control scheme is proposed to supply stable reactive power to the distribution line by compensating a ripple voltage of DC link. In a single-phase system, a magnitude of second harmonic is inevitably generated in the DC link voltage, and this phenomenon is further increased when the capacity of DC link capacitor decreases. Reactive power control was performed by controlling the d-axis current in the virtual synchronous reference frame, and the voltage control for maintaining the DC link voltage was implemented through the q-axis current control. The proposed method for compensating the ripple voltage was classified into three parts, which consist of the extraction unit of DC link voltage, high pass filter (HPF), and time delay unit. HPF removes an offset component of DC link voltage extracted from integral, and a time delay unit compensates the phase leading effect due to the HPF. The compensated DC voltage is used as feedback component of voltage control loop to supply stable reactive power. The performance of the proposed algorithm was verified through simulation and experiments. At DC link capacitance of 375 uF, the magnitude of ripple voltage decreased to 8 Vpp from 74 Vpp in the voltage control loop, and the total harmonic distortion of the current was improved.

DZDC Coefficient Distributions for P-Frames in H.264/AVC

  • Wu, Wei;Song, Bin
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.814-817
    • /
    • 2011
  • In this letter, the distributions of direct current (DC) coefficients for P-frames in H.264/AVC are analyzed, and the distortion model of the Gaussian source under the quantization of the dead-zone plus-uniform threshold quantization with uniform reconstruction quantizer is derived. Experimental results show that the DC coefficients of P-frames are best approximated by the Laplacian distribution and the Gaussian distribution at small quantization step sizes and at large quantization step sizes, respectively.

Analysis on Electric Shock Current in DC Electricity (직류환경에서 인체에 흐르는 감전전류 분석)

  • Lee, Jin-Sung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.254-259
    • /
    • 2016
  • Recently, DC distribution systems have become a hot issue because of the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. To obtain the practical usage of DC electricity, safety should be guaranteed. The main concerns for safety are twofold: one side is human protection against electric shocks, and the other is facility protection from short faults. "Effects of current on human beings and livestock" (IEC 60479) defines a human body impedance model in electric shock conditions that consists of resistive components and capacitive components. Although the human body impedance model properly works in AC electricity, it does not well match with the electric shock behavior in DC electricity. In this study, the contradiction of the human body impedance model defined by IEC 60479 in case of DC electricity is shown through experiments for the human body. From the analysis of experimental results, a novel unified human body impedance model in electric shock conditions is proposed. This model consists of resistive components, capacitive components, and an inductance component. The proposed human impedance model matches well for AC and DC electricity environments in simulation and experiment.

Transient Response Improvement at Startup of Three Phase AC/DC Converter for DC Distribution System in Building Applications (빌딩용 직류배전 시스템의 3상 AC/DC 컨버터의 기동 시 과도상태 응답 개선)

  • Shin, Soo-Cheol;Lee, Hee-Jun;Lee, Jung-Hyo;Na, Jong-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.138-144
    • /
    • 2013
  • Most of the DC loads have had the sensitive characteristics electrically for input voltage. In this system, power converter is operated after connecting with DC loads to minimize the overshoot of the control voltage that may occur during connection of the loads. But whenever starting the power converter, parameters in circuit are different because power converter has been connected with diverse load types at each startup time. This is cause of a disadvantage to PI controller design of power converter. In this paper, the novel voltage control method using sliding mode control theory has proposed. This control method minimizes the overshoot of control voltage at startup of power converter. Despite the variations of the system parameters, the proposed voltage controller has fast response and robustness characteristics such as PI and sliding mode controllers. The proposed controller was applied to the three-phase AC/DC converter and each performance of controller was verified.

The Measurement System of Space Charge Distribution in Polymer Dielectric Materials by the PEA Method (펄스정전응력법(PEA)을 이용한 고분자 유전체 내의 공간전하분포 측정시스템)

  • Hwang, Bo-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1403-1411
    • /
    • 2012
  • In this paper, we have evaluated theoretically the PEA method which is the most popular methods for the non-destructive measurement of space charge distribution in polymer dielectric materials and is recently one of big issues in DC high voltage cables. On the basis of theoretical evaluation, we have developed the space charge measurement system in polymer dielectrics under DC appled voltage and improved the accuracy of space charge distribution by applying the deconvolution process for distorted signals.