• Title/Summary/Keyword: Daylighting factor

Search Result 46, Processing Time 0.034 seconds

Visual Comfort Evaluation of Interior Spaces by Daylighting Systems (채광시스템 유형별 실내공간의 시각적 쾌적성에 관한 평가)

  • Jeong, In Young;Choi, Yoon Seck;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Daylight is a critical factor in architecture, as it enhances the working efficiency and visual comfort of the people working inside. Even though, low transmittance glazing has been used in the most office buildings in Korea. And it is reduced visual comfort in a indoor environment. So, we need to evaluation of quality for various daylighting systems to improve visual comfort This study aims to evaluate the visual comfort in a indoor environment by different daylighting system. For the purpose, four different daylighting systems-conventional window, conventional window with interior lightshelf, differentiated window, differentiated window with interior lightshelf-were selected and a questionnaire survey with 50 subjects were conducted. The results are as follows. Regardless daylighting systems, a view has an effect on visual comfort. A conventional system and conventional system with lightshelf were highly correlated between comfort and warmth. In case of differentiated window system were correlated between comfort and openness. Also, differentiated window with interior lightshelf were highly correlated between comfort and stability.

Performance Evaluation of An Azimuth Tracking Prismatic Daylighting System (방위각 추적식 프리즘형 집광조명시스템 성능평가)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Lee, Eul-Young;Park, Yeon-Min;Joung, Che-Bong;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • This thesis introduced an azimuth tracking prismatic daylighting system. The system improved several issues of the previous passive prismatic daylighting system: low efficiency at sunrise and sunset, glare effect and polarized. The system was developed to track the movement of sun with azimuth tracking device, and it has its own power from the attached solar cells. We compared the with previous passive one in terms with system efficiency and daylighting factors(DF).

A Daylighting Design Indicator for Korean Dementia Nursing Homes Based on the Therapeutic Effects of Light - Focusing on maximizing daylight availability, optimizing therapeutic views, and minimizing glare (빛에 의한 치료적 효과 기반의 한국형 치매요양시설의 자연채광 계획지표 개발 - 주광 가용성 최대화, 치료적 조망 최적화 및 현휘 최소화 지표 중심으로)

  • Jee, Soo In
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.29-42
    • /
    • 2023
  • Purpose: This study aimed to develop a daylighting design indicator for Korean dementia nursing homes based on the therapeutic effects of light, focusing on the serious aging index facing Korea and the importance of natural light that occupies the most important position in the therapeutic environments for the elderly with dementia. Methods: A wide range of literature-oriented research methods were mobilized to develop the daylighting design indicator of Korean dementia nursing homes. Results: The daylighting design indicator of Korean dementia nursing homes was derived from three perspectives: maximizing daylight availability, optimizing therapeutic view, and minimizing glare. In addition, eighteen basic indicators were derived within seven indicator items in the range of building layout, windows, glazing, shading devices, spaces, interior finishings, and daylight factor. Implications: The daylighting design indicator of Korean dementia nursing homes revealed in this study will contribute to realizing Korean dementia nursing homes as a therapeutic environment for the elderly with dementia.

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계와 주광율의 직접조도분에 의한 채광창의 평가)

  • Chee, Chol-Kon;Kwon, Young-Hye
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.210-213
    • /
    • 1988
  • A new and accurate expression to derive a window area is presented with a sequence for daylighting design using Daylight Factor Method process not in its classical point--by-point method but in lumen method as in artificial lighting design process to consider daylight in the early stage of a building design process. Accepting CIE Overcast Sky as the worst state with the lowest sky luminance, a user of a room can have more available daylight in his or her room. In the design process uniformity is checked to ensure reasonably even daylighting by comparing the depth of the room with the computed limiting depth. After these steps the shape and position of window is altered, of which the Sky Component of Daylight Factor under an Overcast Sky, SCo, is investigated and computed in Composite Simpson Multiple Integral so that a building designer or an analyst can choose the best shape and location that satisfies his/her taste and purpose of the room.

  • PDF

Daylighting of Underground Parking Lots in Apartment Housings by Field Survey and Performance Evaluation (공동주택 지하주차장의 자연채광 실태 및 채광성능 평가)

  • Chung, Yu-Gun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, underground spaces can be usually applied to the alternative of land use for parking. However, lack of window and natural light are among the most cited drawbacks associated with dark image of underground. If underground parking lots are designed to be positive and safe environment for people, openings for daylighting will play a significant role. The natural light and unobstructed view to outdoor are main elements to create optimal underground parking lots. This paper focuses on investigating the actual day lighting conditions and evaluating the day lighting performance of openings as potential lighting resources. For the study, the field measurements and Questionnaire surveys are conducted. And then, the day lighting performance of underground parking lots based on opening geometry and orientation are evaluated by scaled model experiments. As results, the feelings of safety and orientation of underground parking lots are improved by openings for day lighting regardless of the sizes. The required illuminances (daylight factor 0.5%) for underground parking lots can be satisfied in the skylight opening ratio of 4% or more.

Assessment of the Daylighting Performance in Residential Building Units of South Korea through RADIANCE simulation (시뮬레이션을 이용한 주거용 건축물의 공간별 채광성능 평가)

  • Lim, Tae Sub;Lim, Hong Soo;Koo, Jae-O;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.25-32
    • /
    • 2012
  • This paper focused on the daylighting performance of residential high-rise buildings in South-Korea. the purpose of this study is to estimate the visual environment of sunlight coming into opening according to sky conditions, orientation of windows and each space of Apartment buildings. Season of the year, weather, and time of day combine with predictable movement patterns of the sun to create highly variable and dynamic daylighting conditions. Daylighting design is usually based on the dominant sky condition and the micro-climate for the building site. There are three common sky conditions: clear sky, overcast sky, and partly cloudy sky. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Easily used charts, diagrams, and software programs allow study of solar geometry for any geographic location and time of day. on the other hand, the overcast sky is characterized by diffuse and variable levels of light and has dense cloud cover over 90% of the sky. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.

Development of Solar Daylighting System Using Parabolic Mirrors (포물면 집광거울 방식의 태양광 집광채광시스템 개발)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Kim, Jong-Min;Joung, Che-Bong;Kim, Byung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.240-245
    • /
    • 2013
  • We developed a parabolic reflector based daylighting system which can be used as an alternative indoor daytime lighting device such as for fluorescent lamps. The system comprises three main components : a daylight concentrator made of 4 pairs of parabolic reflectors and mirrors, a silica optical fiber bundle based light transmitter, and 4 light diffusers for the final indoor delivery of the collected daylight. We analyzed the performance of the system and revealed the system efficiency and daylighting factor. All test methods follow the rule, NR PV601 : 2007-daylighting system, governed by Korea Energy Management Corporation.

A solution method of view factor by the area weighted average and graphical methods (면적가중 평균법과 그래프 해법에 의한 형태계수의 해석)

  • 유승호;손장열
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.709-715
    • /
    • 1999
  • To optimize a heating and cooling system, we need an exact solution lot radiant heat transfer in any form of room or building. This paper describes the solution method of view factor by the area weighted average and graphical method to calculate the radiant heat exchange or daylighting level in any form of room or building. This study shows that the area weighted average and graphical methods have many points of merits(calculation speed, correctness and calculation capability in an arbitrary form of room shapes etc.) compared with existing methods

  • PDF

A Study on the Experiment of Luminous Environment in Classroom of An Elementary School (초등학교 교실의 빛 환경 실측에 관한 연구)

  • Park, Kyung-Eun;Kim, Jun-Tae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.5
    • /
    • pp.13-21
    • /
    • 2002
  • Daylighting in educational environment is very important as it has an effect on students' performance as well as in their visual health. It is regarded as a good energy conservation method in saving energy used for lighting. This study conducted initial daylight measurements to analyze luminous environment in classrooms of Korean elementary school. The results indicated that the typical classroom had a reasonable level of daylight. However, it also found that the classroom had some problems of the uniformity of illuminance and the contrast of brightness of surfaces in the classroom. It is argued that daylighting design for school classroom should consider these aspects to make daylit classrooms ideal so as to provide comfortable visual environment.