• Title/Summary/Keyword: Daylight illuminance

Search Result 91, Processing Time 0.027 seconds

The Influence of Illuminance Variation by a Daylight Dimming Control System on Visual Comfort Under Clear Sky Conditions (청천공 조건에서 조광제어 시스템 적용시 조도변화에 대한 시각적 만족도 분석)

  • Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.553-561
    • /
    • 2010
  • This study examines the influence of light variation on visual responses in a small office space where a daylight dimming control system is applied. Field measurements and survey were performed in a full-scale mocked-up small office space under clear sky day conditions. Maximum fluctuation range for desktop was 133.5 lx and it just happened once for entire monitoring period. For the majority of time, the fluctuation range did not exceed 50 lx, which did not cause visual discomfort to subjects. The daylight dimming control system successfully kept required illuminance levels for an office environment when desktop illuminance by daylight ranged up to 300 lx. The most serious contributor to the sensation of glare was direct daylight through window. The dimming of electric light was not a significant contributor to visual discomfort for the subjects under clear sky day conditions. Visual comfort was significantly influenced by the sensation of glare, feeling for visual stimulation and distraction, and required illuminance level.

A Study on the Prediction of Lighting Energy Savings from Daylight (자연채광에 의한 조명에너지 절감의 예측에 관한 연구)

  • Lee, S.B.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.67-75
    • /
    • 1998
  • Daylight illuminance are always changing. Nevertheless, when the energy savings due to daylight are calculated an accurate estimate of daylight availability is required. Where artificial lighting is photoelectrically controlled the relevant quantity is the cumulative distribution of daylight illuminance. This paper describes an experiment which measured daylight illuminance over one whole working year. Also using measured data on availability of daylight, equations are drived to predict the maximum possible savings from photoelectric controls for an interior lighting installation. The equations are applied to a space as a worked example and figures are given for the relative maximum savings in artificial lighting use of three control systems: on/off, dimming and mixed.

  • PDF

Analyses of the Impact of Atmospheric Conditions to Daylight Illuminance in a Small Space (기상인자의 변화에 따른 소규모 공간에서의 주광조도분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • Daylight illuminance levels in a small space were calculated using the Superlite program under limited conditions of the turbidity and thickness of condensible water of atmosphere. Three sky conditions(clear sky with direct sun, clear sky with no direct sun, overcast sky with no direct sun) were used. The atmospheric conditions significantly impacted the illuminance levels under especially a clear sky with direct sun. The overcast sky with no direct sun provided no difference for the illuminance levels in the space. As the calculation points moved away from a window, reflected illuminance levels gradually increased but direct illuminance levels significantly decreased.

An Analysis of Illuminance Distribution in Fine Art Museum with Girdle Skylight Type (미술관에서의 상부 띠형 천창의 채광분포에 관한 연구)

  • Choi, Man-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.93-100
    • /
    • 2005
  • Character and illuminance distribution of daylighting is very important for the architectural plan in museum. Those data show bases for exhibition space design with daylighting and play a decisive role in visual perception of articles and space aesthetic. The goal of this paper was therefore to analyze the illuminance distribution in fine art museum with 3 typical girdle skylight types which are devided according to the art of protection from glare. This Experiment proved that they had a striking contrast with regard to the ratio of daylight illumination and illuminance distribution in spite of the same purpose of those development. The girdle skylight with a translucent glass showed the strongest value of the ratio of daylight illumination, but inequable illuminance distribution in space, excepting the area of the wall. However, the latticed reflector of light refracted daylight in the direction of wall and made illuminance distribution very equable in whole space. The ratio of daylight illumination at the girdle skylight which was located at the verge of the ceiling, was highest at the upper part of the wall and was reduced gradually from there, by way of the middle and under part of the wall, to the center of space.

A Fundamental Study on the Photosensor Modeling for the Daylight Responsive Dimming System - Using RADIANCE Program (광센서 조광제어시스템에서의 광센서 모델링에 관한 기초적 연구 -RADIANCE 프로그램 활용-)

  • Hong, Seong-Kwan;Park, Byoung-Chul;Choi, An-Seop;Lee, Jeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.97-100
    • /
    • 2008
  • The daylight responsive dimming system is an energy saving system that automatically controls lighting output of artificial lighting according to available daylight in inside, as well as keeps uniform workplace illuminance. The basic three components of the daylight responsive dimming system consist of a photosensor, a controller and a dimming ballast. This paper is a fundamental study of photosensor modeling for the daylight responsive dimming system. The correlation between photosensor illuminance on the ceiling and workplace illuminance is an important factor to accuracy of system performance, so that the purpose of this study is to improve accuracy for daylight responsive dimming system. This study performs to derive the optimized conditions of photosensor using the RADIANCE.

  • PDF

A Study on Determination of Poiling Period of Daylight Responsive Dimming Systems (광센서 조광제어시스템의 폴링주기 결정에 관한 연구)

  • Hwang, Min-Gu;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.213-216
    • /
    • 2005
  • Recently, energy depleting problem have risen seriously. Many studies of daylight responsive dimming system for saving of lighting energy in office buildings have been done actively. Most of studies are focused on the accuracy. However if the variation of dimming levels is changed too often, occupants would feel uncomfortable. First, illuminance changes which occupants couldn't detect are studied through analyzing foreign studies. Second, workplan illuminance from daylight in each sky condition is measured. Because the dimming level In daylight responsive dimming system is dependent on the workplan illuminance from daylight. In conclusion, the most appropriate polling periods to daylight responsive dimming system for occupant's visual comfort was determined.

  • PDF

Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office (소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측)

  • Gu, Renyan
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.79-89
    • /
    • 2021
  • This simulation based study analyzed the horizontal daylight distribution on the floor and ceiling of a small office space based on window orientations and interior window blind positions. South and north facing windows were each tested without window blinds and with window blinds at 45° and 180° (horizontal). The study showed that the illuminance value was highest 1m from the window. On the floor and ceiling, the difference in illuminance value was the greatest and least in December and June, respectively. The indoor illuminance value was highest when there was no window blind and under south-facing conditions. The greatest illuminance difference occurred between window blinds positioned at 45° and 180°. Under north-facing conditions, windows without blinds or with blinds at 45° had the least impact on indoor illuminance with illuminance being more evenly distributed.

A Study on the Comparison of the Illuminance Values from Lighting Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (조명시뮬레이션의 적절한 사용을 위한 Mock-up 실험 측정값과 주광 시뮬레이션 결과값 비교에 관한 연구)

  • Lim, Ji-Sun;Jun, Byung-Kuk;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.17-20
    • /
    • 2009
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architecture design has need of daylight prediction for reflection efficiently daylight. But it is difficult to predict the illuminance values in daylight system. Using various lighting simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, RELUX 2007, RADIANCE 3.9) and Mock-up experiment with the same space and parameter of daylight (location of space and window, date, time and sky condition).

  • PDF

A Study on the Comparison of the Illuminance Values from Daylight Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (적합한 조명시뮬레이션 사용을 위한 주광 시뮬레이션과 Mock-up 실험 비교에 관한 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2010
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architectural design has a need for daylight prediction. But it is difficult to predict the illuminance values in daylight system. Using various Daylight simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, Relux 2007, Radiance 3.9) and Mock-up experiment with a same space and parameter of daylight (location of space and window, date, time and sky condition).

Analyses on Daylight Variations for Optimum Controls of Daylight Dimming Systems in a Small Office (소규모 사무실에 적용된 조광제어 시스템의 최적제어를 위한 주광변화 분석)

  • Yoon, Youn-Ju;Baik, Yong-Kyu;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.433-442
    • /
    • 2012
  • The influence of outdoor sky conditions on photosensor signals were examined to determine an appropriate index that is effectively used for optimum illuminance fluctuation when a daylight dimming system is used for a small office. Field measurements were conducted under various sky conditions. Results indicate that the outdoor global and vertical illuminance fluctuated within narrow ranges under clear and overcast sky conditions. The fluctuation of sky ratio under partly-cloudy sky caused wide ranges of illumnance fluctuation. A partially-shielded photosensor at backwall produced 56% of light output from fixtures controlled by a photosensor at ceiling. This implies that the photosensor at backwall does not always guarantee target illuminance due to the less output. The fluctuation of light output from fixtures were insignificant under clear and overcast sky. The fluctuation range of photosensor illuminance under partly-cloudy sky caused wide fluctuation ranges of light output. Regression result implies that the outdoor vertical illuminance was recommended for an effective index that is used for control of light output.