• Title/Summary/Keyword: Daylight Control System

Search Result 60, Processing Time 0.025 seconds

Control Efficiency of a Daylight Dimming System for Indirect Lighting in a Small Office (소규모 사무실 공간에서 간접조명에 대한 조광제어 시스템효율)

  • Kim, Soo-Young;Jung, Yong-Ho;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.33-43
    • /
    • 2006
  • Daylight dimming control system was analyzed for an indirect lighting system in a small office space with a double skin envelope system. Computer simulations were performed for photosensors with three shielding conditions. The photosensors were placed on the center of ceiling, and backwall. Three sky conditions defined by CIE were considered. Overall, control performance was not very excellent for all conditions. Fully-shielded photosensor achieved good control performance for some cases, but partially-shielded and unshielded photosensors failed to achieve target illuminance. The variation in desktop illuminance due to daylight was examined for a variety of daylight conditions. Linear correlation between desktop illuminance and photosensor illuminance was analyzed using ANOVA.

A Study on Selection of a Control Slope for Daylight Responsive Dimming Systems (광센서 조광제어시스템의 제어기울기 선정방법에 관한 연구)

  • Joo, Keun-Tak;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.179-184
    • /
    • 2005
  • The daylight responsive dimming systems, which use daylight and automatically controls the brightness of electric lighting, according to the amount of daylight coming into the indoor, as well as always maintains target illuminance, is an energy saving type system. The control slope that decide the dimming percent for dimming ballast to run this system efficiently should be decided exactly. This research ran performance assessment applying daylight responsive dimming systems to actual space, and supplemented control slope in the sky condition for the elevation of system. Also we revaluated a system by modified control slope and compiled valid propriety and alternative for the elevation system.

  • PDF

Study on the Analysis and the Application of State-of-the-Art Daylighting Design Cases - Based on the Case Studies of LEED(Leadership in Energy and Environmental Design) Multi-Family housing - (최신 자연채광 디자인 사례들 분석 및 그 적용에 관한 연구 - 미국 LEED 인증 공동주택 사례분석을 바탕으로 -)

  • Yoon, Hea-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.265-273
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art daylighting design among LEED(Leadership in Energy and Environmental Design) multi-family housing cases and to explore the feasibilities for their applications in domestic housing design. Occupants in multi-family houses are reported to consume more electricity power than those in single houses. That may imply the problems of daylighting design in domestic housing design for multi-family houses have better insulation system and less windows and outside walls than single houses. Therefore two systems, daylight delivery system and daylight control system, are scrutinized for daylighting design with LEED cases. The findings show when windows as a daylight delivery system are combined with overhangs, fins, louvers, fenestration materials, speciality fenestration, or interior controls as a daylight control system, the outcome goes with more energy savings and better facade design. Beside those, lightshelves as a daylight delivery system seem to have potentials in domestic multi-family houses with deep plans and less outside walls. Daylighting designs in domestic multi-family houses need to pursue available options more to achieve the integration of energy and aesthetics values.

Analyses on Photosensor Illuminance for Prediction of Fluctuating Illuminance by Daylight Dimming Control Systems (조광제어 시스템 적용시 실내조도의 변동예측을 위한 포토센서의 주광조도 분석)

  • Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.788-797
    • /
    • 2010
  • This study examines the influence of fluctuating daylight illuminance on daylight dimming control systems. Field measurements were performed for a full-scale mocked-up model under various daylight conditions in winter. Fluctuating ranges for a partially-shielded photosensor were great when the variation of sky ratio was great. When solar altitude was lower the illuminance and fluctuating range of illuminance were great due to the influence of direct components of daylight and the interrefelction between surfaces in rear area of space. It implies that daylight dimming system would not function effectively, unless the desktop illuminance by daylight is enough. Fluctuation ranges of photosensor illuminance were lower than 50 lx under clear sky conditions, but they were greater than 100 lx under partly-cloudy sky conditions. It means that the fluctuation range of electric light output of lighting fixture would greater under the partly-cloudy conditions and cause potential visual annoyance to occupants. Outdoor vertical illuminance reaching the windows would be an effective factor that can be used to predict the fluctuation of photosensor signals for effective controls of daylight dimming system.

The Influence of Illuminance Variation by a Daylight Dimming Control System on Visual Comfort Under Clear Sky Conditions (청천공 조건에서 조광제어 시스템 적용시 조도변화에 대한 시각적 만족도 분석)

  • Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.553-561
    • /
    • 2010
  • This study examines the influence of light variation on visual responses in a small office space where a daylight dimming control system is applied. Field measurements and survey were performed in a full-scale mocked-up small office space under clear sky day conditions. Maximum fluctuation range for desktop was 133.5 lx and it just happened once for entire monitoring period. For the majority of time, the fluctuation range did not exceed 50 lx, which did not cause visual discomfort to subjects. The daylight dimming control system successfully kept required illuminance levels for an office environment when desktop illuminance by daylight ranged up to 300 lx. The most serious contributor to the sensation of glare was direct daylight through window. The dimming of electric light was not a significant contributor to visual discomfort for the subjects under clear sky day conditions. Visual comfort was significantly influenced by the sensation of glare, feeling for visual stimulation and distraction, and required illuminance level.

Analysis on Dimming Control Effect by Algorithm Variation for Direct/Indirect Lighting in a Small Office (알고리듬 변화에 따른 직/간접 조명시스템에 대한 디밍제어 효과분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.36-48
    • /
    • 2008
  • This study examines the influence of control algorithms on dimming performance to determine appropriate control setting when direct/indirect lighting is controlled by a daylight dimming system. Computer simulation were performed for a small office with double skin envelope under various daylight conditions. A retractable fabric shading and Venetian blind were applied for internal and external envelopes under three CIE standard sky conditions. Unshielded and partially-shielded photosensors were used, and three control algorithms were applied for the sensors. In general, dimming level was too excessive due to the direct impact of light from lighting fixture to the photosensor. Providing insufficient lighting output, the unshielded photosensor completely failed to secure required illuminance under any daylight condition. When a partially-shielded photosensor was applied under clear sky, three setting points functioned effectively. Less sensitivity for the partially-shielded photosensor was effective to control the dimming system optimally with reasonable energy saving. However, the daylight dimming control system for direct/indirect lighting does not appear to be energy effective when photosensors without enough shielded area is installed on ceiling where light from fixtures reaches directly.

Validation of a Daylight Measurement System Using the CIE Guide of Recommended Practice of Daylight Measurement (CIE 권장가이드를 이용한 자연채광 기후요소 측정시스템의 유효성 검증)

  • Kong, Hyo Joo;Lee, Jong Soo;Kim, Gon;Yun, Geun Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.41-46
    • /
    • 2010
  • This study is to validate the K University daylight measurement system according to the CIE guide of recommended practice of daylight measurement. In this study global irradiance, illuminance, direct normal illuminance, diffuse irradiance, illuminance and vertical illuminances(North, West, South, East) were measured and compared in accordance with the CIE quality control test. Field monitoring was conducted from 1st August to 15th August 2010. Results for the CIE tests 1 to 4 showed an accuracy of 100%. This indicates that the K University daylight measurement system is reliable and the measurement data would be useful for further daylight researches.

The Influence of Photosensor Configurations on Control Performance of Daylight Dimming Systems in a Small Private Office (소규모 개인 사무실 공간에서 포토센서 적용조건에 따른 디밍 제어효과 분석)

  • Kim, Soo-Young;Lee, Ji-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.231-242
    • /
    • 2011
  • This study examines influences of a daylight dimming control system on the variation of indoor illuminance and lighting energy savings in a small office space. Field measurements and a series of computation were performed for typical types of sky conditions in summer. Results indicate that the daylight illuminance under clear and partly-cloudy sky were close to the target illuminance during a majority of time due to a higher ratio of window to wall. However, the target illuminance was not kept successfully due to the variation of photosensor signals which were strongly influenced by desktop illuminance. The system with partially-shielded conditions succeeded to keep target illuminance under clear sky conditions. The system failed under overcast sky conditions since the electric light output from fixtures caused excessive signals to photosensors due to insufficient daylight on a desktop. Unshielded and fully-shielded conditions were not recommended for effective controls of the systems. The influence of lighting fixtures on photosensors should be minimized to achieve successful lighting controls by daylight dimming systems.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

A Fundamental Study for Calculation of Daylight Responsive Dimming Control Slope in different Height of Roller Shade (Roller Shade 높이 변화에 따른 광센서 조광제어기울기 산정을 위한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.257-262
    • /
    • 2008
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in the room. But, it has a problem of an excessive direct sunlight. This study calculated daylight responsive dimming control slope by Roller Shade system with Mock-up test. With three 1/2 scale Mock-up rooms, we performed a test for calculation of daylight responsive dimming control slope in different shade height of each room through the different height of roller shade systems. This research will be used as a fundamental study for automated roller shade systems.

  • PDF