• 제목/요약/키워드: Datum Shift

검색결과 7건 처리시간 0.019초

데이텀과 위치공차에 최대실체조건이 적용되었을 경우의 위치공차의 Cp (Calculating Cp of Position Tolerance when MMC Applied at Datum and Position Tolerance)

  • 김준호;장성호
    • 산업경영시스템학회지
    • /
    • 제40권3호
    • /
    • pp.1-6
    • /
    • 2017
  • Process capability is well known in quality control literatures. Process capability refers to the uniformity of the process. Obviously, the variability in the process is a measure of the uniformity of output. It is customary to take the 6-sigma spread in the distribution of the product quality characteristic as a measure of process capability. However there is no reference of process capability when maximum material condition is applied to datum and position tolerance in GD&T (Geometric Dimensioning and Tolerancing). If there is no material condition in datum and position tolerance, process capability can be calculated as usual. If there is a material condition in a feature control frame, bonus tolerance is permissible. Bonus tolerance is an additional tolerance for a geometric control. Whenever a geometric tolerance is applied to a feature of size, and it contains an maximum material condition (or least material condition) modifier in the tolerance portion of the feature control frame, a bonus tolerance is permissible. When the maximum material condition modifier is used in the tolerance portion of the feature control frame, it means that the stated tolerance applies when the feature of size is at its maximum material condition. When actual mating size of the feature of size departs from maximum material condition (towards least material condition), an increase in the stated tolerance-equal to the amount of the departure-is permitted. This increase, or extra tolerance, is called the bonus tolerance. Another type of bonus tolerance is datum shift. Datum shift is similar to bonus tolerance. Like bonus tolerance, datum shift is an additional tolerance that is available under certain conditions. Therefore we try to propose how to calculate process capability index of position tolerance when maximum material condition is applied to datum and position tolerance.

지오이드 모델에 따른 Boresight 검정 비교 (Boresight Calibration Comparison Using Geoid Models)

  • 소재경;박영수;원재호;윤희천
    • 한국측량학회지
    • /
    • 제34권3호
    • /
    • pp.291-297
    • /
    • 2016
  • 최근 디지털 항공사진측량 분야에서 Direct Georeferencing 활용이 일반화되었으며, 이때 항공사진의 외부표정요소를 정확히 산출하기 위해 Boresight 검정이 필수적이다. 이 과정에서 높이에 대한 기준인 지오이드 모델을 사용하게 되는데, 지오이드 모델에 따라 Boresight 검정 결과가 다르게 나타날 수 있다. 본 연구에서는 Direct Georeferencing을 통한 외부표정요소 산출에 있어서 Boresight 검정시 지오이드 모델에 따라 그 값에 차이가 발생할 수 있음을 인지하고, 지오이드 모델이 Boresight 검정에 어떤 영향을 미치는지 세 가지 경우로 구분하여 실험하였다. 실험에 사용된 지오이드 모델은 EGM96, EGM08, KNGeoid14이며, 이에 따라 Boresight 검정을 통해 Datum Shift, Boresight Angle을 계산하였다. 또한 각각의 경우를 적용해 외부표정요소 산출 후 DPW(Digital Photogrammetry Worktation)를 이용해 지상기준점을 확인하였다. 본 연구를 통해 지오이드 모델에 따른 Boresight 검정 결과 Datum Shift에서 Z에서 차이가 있었으며, 외부표정요소에서 높이 Z와 회전량 Ω, Φ에서 차이를 보였다. 각각의 경우에서 수치도화기를 이용해 지상기준점과 비교한 결과 지오이드 모델에 따른 관측정확도의 차이는 3cm 내외로, 지오이드 모델이 Boresight 검정에 큰 영향을 미치지 않음을 알 수 있었다.

Geoid 기준설정이 타원체간 좌표변환에 미치는 영향 (The effects of the geoidal height determination in geodetic origin on coordinates transformation between ellipsoids)

  • 강준묵;박운용;이용창
    • 한국측량학회지
    • /
    • 제12권1호
    • /
    • pp.69-76
    • /
    • 1994
  • 본 연구는 측지원점의 지오이드 기준설정에 따른 WGS84 타원체와 Bessel 타원체간의 좌표변환특성을 파악하기 위해, 충남·북 지역내 11개 기준점의 GPS 관측자료를 토대로 원점의 Bessel 타원체면에 기준한 지오이드 고를 다양하게 가정하여 각 경우별로 타원체간의 평균지심편차량을 도출, 지역내 Bessel 지오이드를 모델링하고 이에 연계한 좌표변환을 수행하므로써 Bessel 지오이드 고의 변동에 따른 좌표변환정확도를 고찰한 것이다.

  • PDF

Krassovsky 타원체 좌표의 3차원 변환에 대한 연구 (A Study on 3D-Transformation of Krazovsky Coordinate System)

  • 김감래;전호원;현민호
    • 한국측량학회지
    • /
    • 제19권2호
    • /
    • pp.117-123
    • /
    • 2001
  • 구 소련 지도 확보에 따른 지도의 지형정보 획득이 요구되면서 세계 거의 모든 지역의 지형도를 제작한 구소련 지도의 정확도 분석 및 우리나라 좌표계와의 상관관계분석의 필요가 대두되었다. 국외에서 제작한 지도는 현재 각 나라에서 사용하고 있는 좌표계로 변환을 하여야만 정확한 위치 정보를 획득할 수 있다. 따라서, 이 연구에서는 두 기준 타원체를 사용하여 제작된 지도의 정확도를 비교하기 위해 좌표변환에 대한 이론적 고찰과 투영의 기초가 되는 타원체 형상에 대한 고찰 및 정확도를 평가하였다. 이어 선점한 지점에 대해 각각의 투영법에 따라 좌표값을 독치 한 후, 국내지도와 구 소련 지도를 각각 경위도 좌표와 TM좌표로 비교하여 정확도가 어느 정도인지를 검증하였다. 이를 통해 국내에서 사용 가능한지 여부를 검토한 결과, 각 국가에서 제작된 지도를 국내 좌표체계로 정확히 변환할 수 있는 원점 이동량을 추출해 적용한다면 충분히 사용 가능한 것으로 판단되었다.

  • PDF

다측정 공정능력지수의 특성분석 (Analysis of Process Capability Index for Multiple Measurements)

  • 이도경
    • 산업경영시스템학회지
    • /
    • 제39권1호
    • /
    • pp.91-97
    • /
    • 2016
  • This study is concerned about the process capability index in single process. Previous process capability indices have been developed for the consistency with the nonconforming rate due to the process target value and skewness. These indices calculate the process capability by measuring one spot in an item. But the only one datum in an item reduces the representativeness of the item. In addition to the lack of representativeness, there are many cases that the uniformity of the item such as flatness of panel is absolutely important. In these cases, we have to measure several spots in an item. Also the nonconforming judgment to an item is mainly due to the range not due to the standard variation or the shift from the specifications. To imply the uniformity concept to the process capability index, we should consider only the variation in an item. It is the within subgroup variation. When the universe is composed of several subgroups, the sample standard deviation is the sum of the within subgroup variation and the between subgroup variation. So the range R which represents only the within subgroup variation is the much better measure than that of the sample standard deviation. In general, a subgroup contains a couple of individual items. But in our cases, a subgroup is an item and R is the difference between the maximum and the minimum among the measured data in an item. Even though our object is a single process index, causing by the subgroups, its analytic structure looks like a system process capability index. In this paper we propose a new process capability index considering the representativeness and uniformity.

인체 팬텀(Rando Phantom)을 이용한 CBCT의 Setup 유용성 평가 (Evaluation of Setup Usefulness of CBCT using Rando Phantom)

  • 장은성
    • 한국콘텐츠학회논문지
    • /
    • 제11권7호
    • /
    • pp.234-238
    • /
    • 2011
  • 온보드영상장치(OBI)를 사용하고 있는 콘빔CT(CBCT)를 이용하여 인체 팬텀 자세 및 위치와 모의치료시 인체 팬텀 자세 및 위치를 비교하여 CBCT의 3D 타깃 위치의 유용성을 평가하고자 한다. 실제방사선 치료와 동일한 과정으로 모의 치료계획을 하기 위해서 인체 팬텀(The Rando Phantom) 을 set up 한다. 기준점에 놓인 인체팬텀에서 CBCT를 이용하여 평행이동 및 회전이동 하였다. 이때 얻어진 영상들의 위치 차이에 대한 평균 및 편차를 인체 팬텀의 실제 이동 값과 비교하였다. 실험은 10회씩 반복하여 오차의 표준 편차를 구하였다. CBCT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3D/3D 매칭에서 평균 setup의 residual error의 평균 및 표준편차는 lateral $0.2{\pm}-0.2$ mm, longitudinal $0.4{\pm}0.3$ mm, vertical $-0.4{\pm}0.1$ mm 로 각각 0~4 mm의 범위 이내로 나타났다. 모의실험 된 회전 내용은 $0.4{\pm}0.2$ mm, $0.3{\pm}0.3$ mm, 그리고 $0.3{\pm}0.4$ mm이다. 회전에 의한 error는 $0{\sim}0.6^{\circ}$ 범위이다. 인체 팬텀을 이용한 CBCT 3D/3D 매칭은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 하였다.

입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획 (3-D Conformal Radiotherapy for CNS Using CT Simulation)

  • 추성실;조광환;이창걸
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.90-98
    • /
    • 2003
  • 목적 : 척수에 전이가 가능한 뇌종양 치료를 위한 두개척수 방사선치료를 전산화단층촬영장치(volumetric spiral CT)와 입체조준장치(CT simulator) 및 3차원 조형치료계획장치(3D conformal planning system)를 이용한 두개척수 방사선치료계획 방법을 개발하고 기하학적 검증을 통하여 유용성과 정확성을 평가한다. 방법 : 연세암센터 방사선종양학과에서 두개척수 방사선치료를 받은 환자 11명을 대상으로 전산화 단층촬영을 이용한 입체 모의치료계획과 3차원 방사선조형치료를 시행하였다. 중증의 뇌종양 환자의 두경부는 두부고정틀(thermoplastic mask, $Aquaplast^{R}$)로 고정시키고, 전신은 $Vac-Loc$ $Aquaplast^{R}$ (전성물산, 한국)으로 고정한 후 전산화단층촬영장치(Spiral CT)를 이용하여 전신체적영상(volumetric image)을 얻었다. 환자자세의 재현성 확인 및 검증을 위해 두부에 세 개의 점과 전신에 기준선 및 기준점 등을 표시하였다. 이후 입체조준장치(CT-simulator)의 가상현실영상(virtual fluoroscopy)에서 인체의 크기와 방향에 제약이 없고 치료 침대와 고정기구에 대한 시각장애를 제거함으로써 자유롭게 모의치료를 할 수 있었으며, 조사면과 선속을 결정하고 디지털화재구성사진(digitally reconstructed radiography, DRR)과 디지털화합성사진(digitally composited radiography, DCR)을 통하여 분해능이 좋은 화질의 투시 및 모의치료영상을 획득하였다. 기하학적 검증은 치료중심점 이동시 얻은 모의치료영상과 첫 치료 시에 얻은 조사면 검증 사진(port verification film) 등을 전산화단층촬영영상으로부터 재구성한 DRR 영상과 시각적, 정량적으로 비교, 분석 였다. 결론 : 입체조준장치와 3차원 방사선치료계획 장치 등을 이용하여 두개척수 방사선 치료계획을 신속하고 정확하게 원활히 수행할 수 있었다. 가상현실영상에서 대부분의 설계작업이 이루어지므로 환자의 자세고정을 요하는 시간은 전신체적 영상을 얻는 10분 이내이므로 환자의 불편을 줄일 수 있을 뿐 아니라 모의치료과정 중의 체위 변동 변수를 제거할 수 있었다. 또한 전산화단층촬영영상을 얻음으로써 중요정상조직인 안구, 척수 등을 정확하게 설정할 수 있었고, 조사면 결정과 차폐의 정확성을 증진시킬 수 있었다. 환자자세오차는 디지털화재구성사진과 치료 시마다 얻은 포트필름에서 치료중심점과 척수 사이의 거리를 측정하여 3 mm 이내의 정확성을 얻을 수 있었다. CT조준장치를 이용한 중추신경계의 방사선 입체조형치료는 가상현실모의치료계획으로 두개척수의 방사선치료를 정확하고 용이하게 실현할 수 있었다.

  • PDF