• Title/Summary/Keyword: Data logger

Search Result 178, Processing Time 0.023 seconds

Development of High-insulation Packaging using Recycled PET and Comparison of Insulation Performance with Existing Styrofoam and Paper Boxes (재생페트를 이용한 고단열 패키징 개발과 기존의 스티로폼 및 종이 박스와의 단열성능 비교)

  • Ryu, Jae Ryong;Yook, Se Won;Kal, Seung Hoon;Shin, YangJae
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.111-116
    • /
    • 2019
  • Thermal insulation performance of new insulation packaging made of recycled PET nonwoven (thickness : 10 mm) was verified by conducting comparative experiment with an EPS box (thickness : 25 mm) and a double wall corrugated box (thickness : 7 mm). Three ice packs (300 g) were positioned 200 mm above the bottom inside each box, all of which are placed side by side and temperature change of 2 points (5mm under middle icepack and 130 mm under middle icepack) was recorded by data logger (GL-840, Graphtec) for 16 hours under the environment of 29℃. The new packaging box showed 75% higher insulation performance than the EPS box and 180% higher than the corrugated box. In order to figure out the reason for insulation performance difference among boxes, thermal conductivities of each box material were measured using heat flow meter (HFM436 lamda, Netzsch). U-value (thermal conductivity divided by thickness) of EPS was lower than recycled pet nonwoven by 57%, which seemed to be opposite to the result of insulation test of boxes. This was explained by high water vapor transmission rate of EPS (6 times higher than PET insulation) and air pocket effect of PET insulation.

Fundamental Study of Energy Harvesting using Thermoelectric Module on Road Facilities (열전소자를 활용한 도로구조물에서의 에너지 하베스팅 기초 연구)

  • Lee, Jae-Jun;Kim, Dae-Hoon;Lee, Kang-Hwi;Lim, Jae-Kyu;Lee, Seung-Tae
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : An conventional method for electric power generation is converting thermal energy into mechanical energy then to electrical energy. Due to environmental issues such as global warming related with $CO_2$ emission etc., were the limiting factor for the energy resources which resulting in extensive research and novel technologies are required to generate electric power. Thermal energy harvesting using thermoelectric generator is one of energy harvesting technologies due to diverse advantages for new green technology. This paper presents a possibility of application of the thermoelectric generator's application in the direct exchange of waste solar energy into electrical power in road space. METHODS : To measure generated electric power of the thermoelectric generator, data logger was adopted as function of experimental factors such as using cooling sink, connection methods etc. Also, the thermoelectric generator、s behavior at low ambient temperature was investigated as measurement of output voltage vs. elapsed times. RESULTS : A few temperature difference between top an bottom of the thermoelectric generator is generated electric voltage. Components of an electrical circuit can be connected in various ways. The two simplest of these are called series and parallel and occur so open. Series shows slightly better performance in this study. An installation of cooling sink in the thermoelectric generator system was enhanced the output of power voltage. CONCLUSIONS : In this paper, a basic concepts of thermoelectric power generation is presented and applications of the thermoelectric generator to waste solar energy in road is estimated for green energy harvesting technology. The possibility of usage of thermoelectric technology for road facilities was found under the ambient thermal gradient between two surfaces of the thermoelectric module. An experiment results provide a testimony of the feasibility of the proposed environmental energy harvesting technology on the road facilities.

Methods of temperature measurement of medium in bottle during sterilization (병재배 배지살균 시 배지내부의 실시간 온도측정 방법)

  • Cheong, Jong-Chun;Jhune, Chang-Sung;Lee, Chan-Jung;Oh, Jin-A;Shin, Pyeong-Gyun
    • Journal of Mushroom
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • This study was carried out to develop a method related to measuring the temperature of sterile medium in bottle cultivation. When the medium is sterilized, the device is able to be inserted inside of the medium and the temperature can be directly measured in real time although high temperature and pressure are detected in the sterilization. This device can be able to measure the sterilization temperature in short intervals inside of autoclave and medium used in bottle cultivation. As the method were applied to the field cultivation of mushroom, we could produce mushroom in consistent manner through the optimum sterilization of the medium.

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Analysis on the Characteristics of the Landslide in Maeri (III) - With a Special Reference on Slope Stability Analysis - (매리 땅밀림형 산사태(山沙汰)의 발생특성(發生特性)에 관한 분석(分析) (III) - 사면(斜面)의 안정해석(安定解析)을 중심(中心)으로 -)

  • Park, Jae-Hyeon;Choi, Kyung;Bae, Jong Soon;Ma, Ho-Seop;Lee, Jong-Hak;Youn, Ho-Jung
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.377-386
    • /
    • 2005
  • This study was carried out to analyse the landslide characteristics by ground investigation, borehole image processing system, field seismic test, laboratory test and ground stability analysis at the landsliding area occurred in Maeri, Sangdong-myeon, Gimhaesi, Gyeongsangnam-do. Region I needs to install data logger system to monitor a land displacement during the heavy rainfall events because the region can be liable to occur the land slide by land creeping. It is needed to restore rapidly, if the land displacement occurs in Region I. Region II needs to monitor and repair because of the possibility of slope failure by long-term soil loss. Region III needs constructions to remove ground runoff and ground water to be infiltrated from talus. Region IV where is a stable region, needs to be protected from land cutting or other man-made damage.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

On-Road Driving Performance Analysis of Diesel-Hybrid Bus in Daegu Metropolitan Area (대구지역 디젤하이브리드 버스의 실도로 주행 성능 분석)

  • Kim, Hyunjun;Chun, Bongsu;Han, Manbae;Han, Moonsik;Kim, Yongrae;Lee, Yonggyu;Choi, Kyonam;Jeong, Dongsoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.2
    • /
    • pp.27-33
    • /
    • 2013
  • In this study we analyzed the on-road driving performance of two parallel-type diesel-hybrid buses which have been driven in Daegu metropolitan area. A real-time on-board data logger was facilitated to measure the vehicle information such as vehicle speed, idle stop, state of charge of battery, and engine operating conditions. These diesel-hybrid buses ran as a commuter at Daegu Exco area and Dalsung industrial complex. The driving pattern in Exco area comprised more frequent idle stop and relatively lower speed than at Dalsung area, where comprised no idle stop. Due to those different driving patterns, the fuel economy at Dalsung showed $3.7\;km/{\ell}$, which is about 8% higher than that of Exco. The main causes of this come from the higher portion of regenerative braking and higher speed which moves to the operating points of diesel engine with a lower fuel consumption.

A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube (역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.365-370
    • /
    • 2011
  • The ice-thermal energy storage cooling system has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type system is one kind of ice-thermal storage cooling system utilizing cheaper off-peak electricity. This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by using reversing flow, which is putting reversing material into test section to disturb ice adhesion. At this experiment, poly propylene ball of dimeter 10 mm was used as reversing material, and ethylene glycol-water solution of 20wt% concentration was used as flow material. The experimental apparatus was constructed of the slurry ice making and storage tank(test section), the brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

Effect of once-a-day milk feeding on behavior and growth performance of pre-weaning calves

  • Syed Husnain Mushtaq;Danish Hussain;Hifz-ul-Rahman;Muhammad Naveed-ul-Haque;Nisar Ahmad;Ahmad Azeem Sardar;Ghazanfar Ali Chishti
    • Animal Bioscience
    • /
    • v.37 no.2
    • /
    • pp.253-260
    • /
    • 2024
  • Objective: The objectives of the present study were to evaluate the effects of once-a-day milk feeding on growth performance and routine behavior of preweaning dairy calves. Methods: At 22nd day of age, twenty-four Holstein calves were randomly assigned to one of two treatment groups (n = 12/treatment) based on milk feeding frequency (MF): i) 3 L of milk feeding two times a day; ii) 6 L of milk feeding once a day. The milk feeding amount was reduced to half for all calves between 56 and 60 days of age and weaning was done at 60 days of age. To determine the increase in weight and structural measurements, each calf was weighed and measured at 3 weeks of age and then at weaning. The daily behavioral activity of each calf was assessed from the 22nd day of age till weaning (60th day of age) through Nederlandsche Apparatenfabriek (NEDAP) software providing real-time data through a logger fitted on the calf's foot. Results: There was no interaction (p≥0.17) between MF and sex of the calves for routine behavioral parameters, body weight and structural measurements. Similarly, there was no effect of MF on routine behavioral parameters, body weight and structural measurements. However, the sex of the calves affected body weight gain in calves. Male calves had 27% greater total body weight and average daily gain than female calves. There was no effect of the sex of the calves on behavioral measurements. Collectively, in the current study, no negative effects of a once-a-day milk feeding regimen were found on routine behavioral and growth parameters of preweaning calves in group housing. Conclusion: Once-a-day milk feeding can be safely adopted in preweaning calves from 22nd day of age.

The Effects of Skin Pigmentation on Physiological Factors of Thermoregulation and Grazing Behaviour of Dairy Goats in a Hot and Humid Climate

  • Darcan, Nazan Koluman;Cankaya, Soner;Karakok, Serap Goncu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.5
    • /
    • pp.727-731
    • /
    • 2009
  • The aim of this study was to understand the effects of skin pigmentation on physiological parameters of thermoregulation and grazing behaviour of dairy goats in a hot and humid climate. The study used 26 crossbred Saanen yearling goats (95% Saanen+5% Local Hair Breed). The animals were raised at semi-intensive private farms in Adana (36 59'N, 35 18'E). Groups were selected 2 d before the start of observations. Goats were categorized as predominantly pigmented (P) skin and unpigmented (UP) skin. All observations and measurements were collected on grassland during the grazing period of June and July 2007 (60 d). Air temperature and relative humidity were recorded at 10 min intervals by a portable data logger. The physiological data (rectal temperature, respiration and pulse rate, and skin temperatures from head and udder) were recorded twice weekly in the morning (07:00-08:00); at midday (13:00-14:00); and in the evening (18:00-19:00). Additionally, the activity of the animals was observed and classified (eating, ruminating, drinking, standing, walking, lying) for 12 h during the day twice weekly, using a portable camera system linked directly to a computer. Panting behaviour was also observed. According to the THI values, the experimental goats were subjected to stressful conditions. The pigmented goats had significantly lower rectal temperatures (39.68 vs. $29.89^{\circ}C$), pulse rate (74.08 vs. 84.10 beat/min) and respiration rate (65.65 vs. 88.23 breath/min.) compared with unpigmented goats at midday when the THI exceeded 92. The rectal, head and udder temperatures, pulse and respiration rates of the non-pigmented group exceeded $40^{\circ}C$, $37^{\circ}C$, $37.5^{\circ}C$, 84 beats/min and 78 breaths/min, respectively. Higher activity was observed among pigmented compared with unpigmented goats. Unpigmented goats grazed (4.3 vs. 5.6 h), ruminated (2.0 vs. 2.4 h), and stood (0.8 vs. 1.2 h) less, but lay down (2.2 vs. 1.8 h) more than pigmented goats. The data obtained in this experiment support the hypothesis that unpigmented goats are more adversely affected by climatic stress, likely due to their decreased activity and increased water consumption, as demonstrated by previous studies.