• 제목/요약/키워드: Data leakage

검색결과 1,072건 처리시간 0.03초

플로팅 링 실의 누설 특성에 관한 실험적 연구 (Experimental Study on the Leakage Performance Characteristics of floating Ring Seal)

  • 안경민;이용복;김창호;하태웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.820-825
    • /
    • 2004
  • The floating ring seal is used in an oxidizer and a fuel pump of the turbo pump unit in the liquid rocket engine to optimize a leakage without rubbing phenomenon. The damper floating ring seal, one of the floating ring seals, is with round hole pattern surfaces. It can reduce the leakage by increased friction factor that obtained from experimental data. In this paper, the leakage test about floating ring seal and damper floating ring seal was conducted. The test result showed the leakage performance of damper floating ring seal was better than the leakage performance of floating ring seal. With the leakage test the lock-up and rotation test about seal was conducted and that position is measured. The relatively large lock-up eccentric ratio was obtained from the test result of damping floating ring seal. The attitude angle of seal increases with increasing of shaft rotation

  • PDF

하둡 기반의 사용자 행위 분석을 통한 기밀파일 유출 방지 시스템 (A Digital Secret File Leakage Prevention System via Hadoop-based User Behavior Analysis)

  • 유혜림;신규진;양동민;이봉환
    • 한국정보통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.1544-1553
    • /
    • 2018
  • 최근 산업 보안 정책에도 불구하고 기업의 내부 정보 유출이 심각하게 증가하여 산업별로 정보 유출 방지 대책을 수립하는 것이 필수적이다. 대부분의 정보 유출은 외부 공격이 아닌 내부자에 의해 이루어지고 있다. 본 논문에서는 이동식 저장매체 및 네트워크를 통한 기밀 파일 유출방지를 위한 실시간 내부 정보 유출 방지 시스템을 구현하였다. 또한, 기업 내의 정보 로그 데이터의 저장 및 분석을 위해 Hadoop 기반 사용자 행동 분석 및 통계시스템을 설계 및 구현하였다. 제안한 시스템은 HDFS에 대량의 데이터를 저장하고 RHive를 사용하여 데이터 처리 기능을 개선함으로써 관리자가 기밀 파일 유출 시도를 인식하고 분석할 수 있도록 하였다. 구현한 시스템은 이동식 데이터 매체와 네트워크를 통해 기업 내부로의 기밀 파일 유출로 인한 피해를 줄이는 데 기여할 수 있을 것으로 사료된다.

전향 축류형 홴에서의 익단 누설 유동 구조 (Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan)

  • 이공희;명환주;백제현
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.883-892
    • /
    • 2003
  • The experiment using three-dimensional laser Dopperr velocimetery (LDV) measurements and the computation using the Reynolds stress model of the commercial code, FLUENT, were conducted to give a clear understanding on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition. The tip leakage vortex was generated near the position of the minimum wall static pressure, which was located at approximately 12% chord downstream from the leading edge of blade suction side, and developed along the centerline of the pressure trough within the blade passages. A reverse flow between the blade tip region and the casing, induced by tip leakage vortex, acted as a blockage on the through-flow. As a result, high momentum flux was observed below the tip leakage vortex. As the tip leakage vortex proceeded to the aft part of the blade passage, the strength of tip leakage vortex decreased due to the strong interaction with the through-flow and casing boundary layer, and the diffusion of tip leakage vortex caused by high turbulence. In comparison with LDV measurement data, the computed results predicted the complex viscous flow patterns inside the tip region, including the locus of tip leakage vortex center, in a reliable level.

스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발 (Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter)

  • 김정훈;오정석;이진한
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.57-64
    • /
    • 2023
  • 가스계량기의 검침방식이 발전하면서 원격검침이 가능한 스마트 가스 계량기(누출점검용 계량기 및 다기능 안전 계량기)가 사용되고 있다. 이러한 계량기는 부가기능으로 수집하는 유량 및 압력 데이터를 활용하여 누출 판단을 하는 기능이 있다. 유량 데이터를 이용한 누출판단 기능은 실제 현장에서 유효한 사례가 있지만 압력 데이터 기반 누출 판단 기준은 누출로 인한 압력 값 변화뿐만 아니라 여러 요인(정압기 압력 크기, 인접 계량기 연계, 인접 주택 사용량, 계량기 위치 등)으로 압력 크기 변화(레벨)가 있는 문제점이 있다. 본 논문에서는 스마트 가스계량기에서 수집되는 압력데이터를 활용하여 누출여부를 판단 할 수 있는 기법으로 압력 데이터 전처리 방법과 누출 여부 관련 압력 값 범위 기준, 누출판단 기법 및 적용 사례 검증을 통해 개발하였다.

Nonlinear Regression on Cold Tolerance Data for Brassica Napus

  • Yang, Woohyeong;Choi, Myeong Seok;Ahn, Sung Jin
    • Journal of the Korean Data Analysis Society
    • /
    • 제20권6호
    • /
    • pp.2721-2731
    • /
    • 2018
  • This study purposes to derive the predictive model for the cold tolerance of Brassica napus, using the data collected in the Tree Breeding Lab of Gyeongsang National University during July and August of 2016. Three Brassica napus samples were treated at each of low temperatures from $4^{\circ}C$ to $-12^{\circ}C$ by decrement of $4^{\circ}C$, step by step, and electrolyte leakage levels were measured at each stage. Electrolyte leakages were observed tangibly from $-4^{\circ}C$. We tried to fit the six nonlinear regression models to the electrolyte leakage data of Brassica napus: 3-parameter logistic model, baseline logistic model, 4-parameter logistic model, (4-1)-parameter logistic model, 3-parameter Gompertz model, and (3-1)-parameter Gompertz model. The baseline levels of the electrolyte leakage estimated by these models were 4.81%, 4.07%, 4.19%, 4.07%, 4.55%, and 0%, respectively. The estimated median lethal temperature, LT50, were $-5.87^{\circ}C$, $-6.31^{\circ}C$, $-6.05^{\circ}C$, $-6.35^{\circ}C$, $-4.98^{\circ}C$, and $-5.15^{\circ}C$, respectively. We compared and discussed the measures of goodness of fit to select the appropriate nonlinear regression model.

대화식 주문형 비디오 서비스에서의 셋톱박스 버퍼 제어 방안 연구 (A Study on Buffer Control Method of Set-top Box in Interactive Video-on-Demand Service)

  • 신준호;김용득
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.1041-1044
    • /
    • 1999
  • This paper propose a solution to resolve data overflow or leakage when a subscriber receive data to service provider. The set-top box can communicate with a service provider and can inform the service provider its data overflow or leakage. When service provider received this control signal, it changes data transmit rate and transmits data with changed rate. The buffer of set-top box is important because incoming data from a service provider are stored by it.

  • PDF

콘크리트 표면차수벽형 석괴댐(CFRD)의 누수특성에 관한 사례연구 (A Case Study on the Leakage in Concrete Face Rockfill Dam)

  • 방돈석;신창건;이강용;안상로
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.197-202
    • /
    • 2003
  • The leakage quantity through concrete facing of Concrete Face Rockfill Dam(CFRD) is very small due to its low permeability of intact concrete. Even though the concrete facing is well designed and constructed, fine cracks can be generated due to effects of thermal and drying shrinkage. Therefore, it can be said that the leakage from the CFRD is subjected to not permeability of intact concrete but poor joints, cracks and foundation rocks. The Safety of a dam on leakage was evaluated based on the comparison between apparent permeability estimated and leakage quantity measured. The above method can be concluded to give a good direction for the evaluation of safety on CFRD in maintenance aspects as design and construction technology is improved with the accumulation of leakage data.

  • PDF

옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구 (A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring)

  • 김두현;김은진;김성철
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

누설전류 검출에 의한 ZnO 피뢰기의 열화진단장치 개발 (Development of a Deterioration Diagnostic Device for ZnO Arrester by Leakage Current Detection)

  • 김재철;이보호;오정환;이영길;문선호;김영춘
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.184-189
    • /
    • 1999
  • In this paper, we develope a diagnosis device for ZnO arrester by detecting the leakage current in service. To diagnose the deterioration of ZnO arrester, the device detects the total leakage current which flows between an arrester and ground, and analyzes the resistive current(third harmonic current) which is an indicator of deterioration of ZnO arrester. We use the optical cable which can transfer a detected data without a noise, also use a microprocessor for a data storage, processing, and trend analysis. Experiment are executed to verify its performance in laboratory and the results show that the diagnosis device exactly detects the total leakage current and the resistive current, so it can diagnose the deterioration of ZnO arrester. Also the leakage current of ZnO arrester is detected using the developed diagnostic device in field, these results are presented.

  • PDF

직류 전기철도에서의 레일전위 및 누설전류 해석을 위한 시뮬레이션 모델링 (A Simulation Modeling for Rail Potential and Leakage Current Analysis in DC Traction System)

  • 윤임중;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2008
  • In DC traction systems, a part of feedback current returning through rails becomes leakage current, illumination on a metal laid underground results from the leakage current to ground. To prevent the leakage current on rails, feedback rails almost have insulated with the ground. Insulation between rails and the ground causes that the earth method changes a isolated method in DC traction systems. the rail potential rise results in the isolated method. the rail potential rise causes an electric shock when a person touches the ground and rolling stock. To decrease the rail potential rise and leakage current, there are methods for reducing the feedback resistance and current of rails, increasing the leakage resistance, decreasing the distance between substations. But it are necessary to forecast and analyze the rail potential and amplitude of leakage current. In this paper, we modeled DC traction systems and feedback circuit to simulate the rail potential and amplitude of leakage current using PSCAD/EMTDC that is power analysis program, forecasted the rail potential and amplitude of leakage current about changing various parameters in the electric circuit. By using the simulation model, we easily will forecast the rail potential and amplitude of leakage current in case of a level of basic design and maintenance in electric railway systems, valuably use basic data in case of system selection.

  • PDF