• Title/Summary/Keyword: Data Transfer

Search Result 5,237, Processing Time 0.125 seconds

Managing Flow Transfers in Enterprise Datacenter Networks with Flow Chasing

  • Ren, Cheng;Wang, Sheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1519-1534
    • /
    • 2016
  • In this paper, we study how to optimize the data shuffle phase by leveraging the flow relationship in datacenter networks (DCNs). In most of the clustering computer frameworks, the completion of a transfer (a group of flows that can enable a computation stage to start or complete) is determined by the flow completing last, so that limiting the rate of other flows (not the last one) appropriately can save bandwidth without impacting the performance of any transfer. Furthermore, for the flows enter network late, more bandwidth can be assigned to them to accelerate the completion of the entire transfer. Based on these characteristics, we propose the flow chasing algorithm (FCA) to optimize the completion of the entire transfer. We implement FCA on a real testbed. By evaluation, we find that FCA can not only reduce the completion time of data transfer by 6.24% on average, but also accelerate the completion of data shuffle phase and entire job.

Pool Boiling Heat Transfer Correlation for Pure Refrigerants (순수냉매의 풀비등 열전달 상관식)

  • 고영환;김종곤;송길홍;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.941-949
    • /
    • 2000
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, CFC11, HCFC142b, HFC134a, CFC12, HFC22, HFC125 and HFC32 on a horizontal smooth tube have been measured. The experimental apparatus is specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water as a heat source rather than a conventional electric heat source. Data were taken in the order of decreasing heat flux starting at $80 ㎾/m^2\; and \;ending\; at\; 5㎾/m^2\;in\; the\; poo\;l temperature\; at\; 7^{\circ}C$, Test results showed that HTCs of HFC125, and HFC32 are 50~67% higher than those of HCFC22. It is also found that some of the popular pool boiling heat transfer correlations in the literature are not good to predict the HTCs of newly developed alternative refrigerants. A new correlation was developed by a regression analysis which is based upon the consistent data obtained in this study and it showed an excellent agreement with all experimental data having an absolute mean deviation of less than 10%.

  • PDF

Efficient Oblivious Search on Encrypted Data (암호화된 데이터에서의 OT(Oblivious Transfer)를 이용한 효율적인 검색 기술)

  • Rhee, Hyun-Sook;Park, Jong-Hwan;Lee, Dong-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.13 no.1
    • /
    • pp.43-52
    • /
    • 2008
  • We study the problem of search in which a server contains various multimedia contents and a user wishes to retrieve some multimedia items containing a specific without revealing to the server which items they are. Recently, Ogata and Kurosawa introduced a search scheme by using the notion of oblivious transfer. In their scheme, a user must inefficiently search and compare all the data stored in the seuer for each search query. In this paper, we propose an efficient oblivious search by using the oblivious transfer, in which a user needs not to search and compare all the data. We formally prove that the proposed scheme is secure under the hardness of RSA known target inversion problem.

Transfer Impedence of Trip Chain with a Railway Mode Embedded - Using Seoul Metroplitan Transportation Card Data - (철도수단이 내재된 통행사슬의 환승저항 추정방안 - 수도권 교통카드자료를 활용하여 -)

  • Lee, Mee young;Sohn, Jhieon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1083-1091
    • /
    • 2016
  • This research uses public transportation card data to analyze the inter-regional transfer times, transfer frequencies, and transfer resistance that passengers experience during transit amongst the metropolitan public transportation modes. Currently, mode transfers between bus and rail are recorded up to five times during one transit movement by Trip Chain, facilitating greater comprehension of intermodal movements. However, lack of information on what arises during these transfers poses a problem in that it leads to an underestimation of transfer resistances on the Trip Chain. As such, a path choice model that reflects passenger movements during transit activities is created, which attains explanatory power on transfer resistance through its inclusion of transfer times and frequencies. The methodology adopted in this research is to first conceptualize the idea of metropolitan public transportation transfer, and in the case that mode transfers include the city-rail, to newly conceptualize the idea of transfer resistance using transportation card data. Also, the city-rail path choice model within the Trip Chain is constructed, with transfer time and frequency used to reevaluate transfer resistance. Further, in order to align bus and city-rail station administrative level small-zone coordinates to state and regional level mid-zone coordinates, the big node methdod is utilized. Finally, case studies on trip chains using at least one transfer onto the city-rail is used to determine the validity of the results obtained.

A Protocol for Reliable Data Transfer and Congestion Control in Wireless Sensor Networks (무선 센서 네트워크에서 신뢰성 있는 데이터 전송과 혼잡 제어를 위한 프로토콜)

  • Kim, Hyun-Tae;Joo, Young-Hoon;Ra, In-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.3
    • /
    • pp.230-234
    • /
    • 2007
  • Generally, huge amounts of data traffic are generated by using broadcasting method to deliver sensing data to a sink node reliably so that it makes a severe network saturation problem resulting in unreliable data transfer. In order to handle this problem, a new congestion control protocol is required for supporting reliable data transfer, minimal use of energy and network resources at the same time in wireless sensor networks. In this paper, it proposes a Protocol to guarantee both a reliable transfer in data accuracy and minimum consumption of energy waste by using Hop-by-Hop sequence number and DSbACK(Delayed and Selective ACK Buffer Condition) scheme. In addition, it proves that reliability and energy efficiency are enhanced by the proposed method with the simulation results performed on TinyOS platform which is a component based built-in OS announced by UC Berkely with the performance comparison of other existing methods.

Heat Transfer Characteristics of a Circular Fin-tube Heat Exchanger (원형휜-원형관의 열전달 특성)

  • 강희찬;조동영;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.762-767
    • /
    • 2003
  • An experimental study was conducted to investigate the heat transfer characteristics of a circular finned-tube heat exchanger. The nineteen cases of configuration varying fin material, fin outer diameter and fin pitch were tested by means of the experiment and the numerical calculation. The measured heat transfer data for the circular finned-tube heat exchanger were provided. A transition of heat transfer was found in the case of low fin pitch. The thermal conductivity of fin affected on the pure heat transfer coefficient.

DATA TRANSFER TEST FOR KMTNet DATA (KMTNet 자료 전송 실험)

  • Kim, Dong-Jin;Lee, Chung-Uk;Kim, Seung-Lee
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • We develop a real-time data transfer system for the Korea Microlensing Telescope Network (KMTNet) photometry data and test whether it is suitable for Korea Astronomy and Space Science Institute (KASI) and three different observatories, which are Cerro Tololo Inter-Ameriacan Observatory (CTIO) in Chile, Siding Springs Observatory (SSO) in Australia, and South African Astronomical Observatory (SAAO) in South Africa. For this test, we use a high speed global network being dedicated for researches. From the test, we obtain that the elapsed times between KASI and each three observatories, CTIO, SSO, and SAAO to transfer 650 MB of data are 99.0, 9.2, 119.0 seconds, respectively. This means that the system can be used for the real-time data processing of KMTNet.

A design of P1394 serial bus IC (P1394 시리얼 버스 IC의 설계)

  • 이강윤;정덕균
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.1
    • /
    • pp.34-41
    • /
    • 1998
  • In this paper, I designed a P1394 serial bus chip as new bus interface architecture which can transmit the multimedia data at the rate of 400 Mbps and guarantee necessary bandwidth. because multimedia data become meaningless data after appropriate time, it is necessary to transfer multimedia data in real time, P1394 serial bus chip designed in this paper support isochronous transfer mode to solve this problem. Also, designed P1394 serial bus chip can transfer high quality video data or high quality audio data because it support the speed of 400 Mbps. While user must set device ID manually in previous interface such as SCSI, device ID is automatically determined if user connect each node with designed P1394 serial bus cable and power on. To design this chip, I verified the behavioral of the entrire system and synthesized layout. Also, I did layout the analog blocks and blocks which must be optimized in full custom.

  • PDF

Perception of Transfer Job and Liaison Nursing among Nurses in Neurological Intensive Care Units (전실업무와 연계간호에 대한 신경계 중환자실 간호사의 인식)

  • Yun, Sun Hee;Cho, Ok Hee;Yoo, Yang Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.115-127
    • /
    • 2013
  • Purpose: This study aimed to describe how nurses in neurological intensive care units (ICU) perceive their roles about patient transfer and liaison. Methods: A cross-sectional survey was conducted using a questionnaire developed for the study. Data were collected from a convenience sample of 115 nurses working in the neurological intensive care units ofsix university hospitals. Data were analyzed using SPSS software (version 15.0). Results: Staff nurses were mainly in charge of patient transfer, and the awareness about its importance was significantly related with the burden about the practice of patient transfer (p<.001). Patient liaison was mainly conducted by staff nurses as well. Liaison practice wassuggested to be started from the ICU at the time of transfer; the suggested time for completion of liaison service and evaluation was when patients were adjusted to the transferred ward. Preparing job descriptions and increasing nursing staffing for patient liasion service were strongly recommended. Conclusion: The results suggest that the ICU nurses' burden in relation to patient transfer is commensurate with their awareness about itsimportance. To improve the continuity of care from ICU to transferred ward, it isrequired to reduce the burden about patient transfer and improve perceptions about patient liaison.

An Experimental Study on Condensation Heat Transfer of Low-Finned Tubes (낮은 핀관 (low-fin tube)의 응축 열전달 성능에 관한 실험적 연구)

  • Kim, N.H.;Jung, I.K.;Kim, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.298-309
    • /
    • 1995
  • Low-fin tubes are widely used to enhance condensation heat transfer. In this study, condensation heat transfer experiment was conducted on the low-fin tube using R-11. Three different fin densities-787 fpm (fins per meter), 1102 fpm. 1378 fpm-were tested. The results show that low-fin tube enhances the condensation heat transfer considerablely. The enhancement increases as the fin density increases. It was also found that the fin shape and height have a significant effect on the condensation heat transfer coefficient. Slender or high fins showed a higher condensing heat transfer coefficient compared with fat, low fins. For the tube with 1378 fpm, however, excessive fin height decreased the condensing heat transfer coefficient. The reason may be attributed to the increasing condensate retention angle as the fin density increases. The experimental data are compared with existing prediction models. Results show that Webb's surface tension model predicted the data best (within ${\pm}20%$), which confirms that surface tension plays the major role in low-fin tube condensation.

  • PDF