• Title/Summary/Keyword: Data Leakage Prevention

Search Result 80, Processing Time 0.024 seconds

A Study on the Unbalanced Current Distribution of HTS Power Cable (초전도 전력케이블의 전류 불평형에 관한 연구)

  • Kim, Jae-Ho;Park, Chung-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.

Development of a Novel Real-Time Monitoring System Algorithm for Fire Prevention (화재예방을 위한 실시간 모니터링 시스템의 알고리즘 개발)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.47-53
    • /
    • 2014
  • Despite the automatic fire alarm system, according to the national fire data system of national emergency management agency, the fires account for 40,932 incidents, 2,184 injuries and about 430 billion won in property losses in 2013. Since the conventional automatic fire alarm system has several weaknesses related to electrical signal such as noise, surge, lighting, etc. Most fires are mainly caused by electrical faults, mechanical problem, chemical, carelessness and natural. The electrical faults such as line to ground fault, line to line fault, electrical leakage and arc are one of the major problems in fire. This paper describes the development of a novel real-time fire monitoring system algorithm including fault detection function which puts the existing optic smoke and heat detectors for fire detection with current and voltage sensors in order to utility fault monitoring using high accuracy DAQ measurement system with LabVIEW program. The fire detection and electrical fault monitoring with a proposed a new detection algorithm are implemented under several test. The fire detection and monitoring system operates according to the proposed algorithm well.

A Study on the Fire Risk of Black Box Wiring in Motor Vehicle (자동차의 블랙박스 와이어링 화재 위험성에 관한 연구)

  • Kang, Sin-Dong;Kim, Ju-Hee;Choi, Jun-Pyo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • According to the National Fire Data System (NFDS), more than 5,000 vehicle fires have occurred every year for the last 10 years. Vehicle fires are primarily caused by mechanical (breaking system and engine), electrical (wiring and battery), and chemical (oil and fuel gas leakage) problems. The electrical factor has increased with the installation of driver convenience equipment. For example, today, the black box is widely used to provide video data recording of motor vehicle accidents. The black box consists of a front camera, rear camera, and wires. The black box wires are directly connected to the junction box or fuse box from the start battery that operates to provide normal on power supplying for engine stop. It is extremely dangerous when the wires short circuit due to insulation aging, mechanical and electrical stress, etc. In this study, the black box wiring fire risk have been analyzed and investigated when the steady state and abnormal operations, and under the following conditions: wiring arrangements with a high temperature condition, insulation aging, poor contact, and short circuits. The results showed that black box wiring short circuits had a higher fire risk than the other fire hazard elements. To prevent fire hazards caused by black box wiring, the black boxes must be installed by qualified service personnel. Do not modify the wiring, remove the fuse and secure the wiring using cable ties or insulation tape.

Estimation of the Relative Risk of the Elderly with Different Evacuation Velocity in a Toxic Gas Leakage Accident (독성물질 누출 시 대피 속도 차이에 따른 고령자의 상대적 위험도 산정)

  • Lee, H.T.;Kwak, J.;Park, J.;Ryu, J.;Lee, J.;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.13-21
    • /
    • 2019
  • Leakage accidents in businesses dealing with hazardous chemicals can have a great impact on the workers inside the workplace, as well as residents outside the workplace. In fact, there were cases where hazardous chemicals leaked from many businesses. As a result, the Chemicals Control Act(CCA) was enacted in 2015, the Ministry of Environment introduced an Off-site Risk Assessment(ORA). The purpose of the ORA is to secure safety from the installation of the design of the workplace facilities so that chemical accidents of hazardous chemical handling facilities do not cause human or physical damage outside the workplace. In general, the ORA qualitatively determines where a protected facility is within the scope of the accident scenario. However, elderly who belong to the sensitive group is more sensitive than the general group under the same chemical accident effect, and the extent of the damage is serious. According to data from the Korea National Statistic Office, the number of elderly people is expected to increase steadily. Therefore, a quantitative risk analysis considering the elderly is necessary as a result of a chemical accident. In this study, accident scenarios for 14 locations were set up to perform emergency evacuation due to toxic gas leakage of Cl2(Chlorine) and HF(Hydrogen Fluoride), and the effects of exposure were analyzed based on the evacuation velocity difference of age 20s and 60s. The ALOHA(Areal Locations of Hazardous Atmospheres) program was used to calculate the concentration for assessing the effects. The time of exposure to toxic gas was calculated based on the time it took for the evacuation to run from the start point to the desired point and a methodology was devised that could be applied to the risk calculation. As a result of the study, the relative risk of the elderly, the sensitive group, needs to be determined.

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

The Remote Wireless Corrosion Monitoring System for Water Pipeline (상수도 배관용 무선 원격 부식모니터링 시스템)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.637-640
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in oder to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. In this paper, results of development about remote wireless corrosion monitoring system for water pipe line are presented briefly.

  • PDF

The Safety Design of Corrosive Chemical Handling Process based on Reliability Database (신뢰도 데이터베이스 기반 부식성 화학물질 취급공정의 안전설계)

  • Chu, Chang Yeop;Baek, Jong Bae
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.141-149
    • /
    • 2018
  • In a PCB factory, there is a corrosive chemical substance supply system that can causes major leakage accidents. These accidents can give rise to shut down the factory and do residents damage that cause enormous loss of properties. To mitigate these risks, it is necessary to provide a chemical disaster prevention system. Moreover, after considering the situation and environment of the production site, it is of great importance to build an optimal chemical accident prevention system by reflecting risk reduction measures from the point of process design and by assessing quantitative risk based on reliability data. However, because there was no established database of the reliability about facilities and equipment that can be used in the domestic, the business site and consulting organization had being used the reliability data such as USA CCPS(Center for Chemical Process Safety). In these days, Korean institutes are studying on reliability data utilization method of quantitative risk assessment for preventing chemical accidents and domestic utilization algorithms and storage bed of reliability data. This study presents samples of reliability database about the chemical substance supply system that constructed from the history data such as failure, maintenance for 10 years at a PCB factory. Also, this work proposes the safety design criteria for supply facilities of corrosive chemical substance by assessing quantitative risk on the basis of the reliability data.

Study on Detection Technique of Privacy Distribution Route based on Interconnection of Security Documents and Transaction ID (보안문서와 트랜잭션ID 연계기반 개인정보유통경로 탐지기법 연구)

  • Shin, Jae-ho;Kim, In-seok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.6
    • /
    • pp.1435-1447
    • /
    • 2015
  • Finance Companies are operating a security solution such as E-DRM(Enterprise-Digital Right Management), Personal information search, DLP(Data Loss Prevention), Security of printed paper, Internet network separation system, Privacy monitoring system for privacy leakage prevention by insiders. However, privacy leakages are occurring continuously and it is difficult to the association analysis about relating to the company's internal and external distribution of private document. Because log system operated in the separate and independent security solutions. This paper propose a systematic chains that can correlatively analyze business systems and log among heterogeneous security solutions organically and consistently based on security documents. Also, we suggest methods of efficient detection for Life-Cycle management plan about security documents that are created in the personal computer or by individual through the business system and distribution channel tracking about security documents contained privacy.

The Proactive Threat Protection Method from Predicting Resignation Throughout DRM Log Analysis and Monitor (DRM 로그분석을 통한 퇴직 징후 탐지와 보안위협 사전 대응 방법)

  • Hyun, Miboon;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.369-375
    • /
    • 2016
  • Most companies are willing to spend money on security systems such as DRM, Mail filtering, DLP, USB blocking, etc., for data leakage prevention. However, in many cases, it is difficult that legal team take action for data case because usually the company recognized that after the employee had left. Therefore perceiving one's resignation before the action and building up adequate response process are very important. Throughout analyzing DRM log which records every single file's changes related with user's behavior, the company can predict one's resignation and prevent data leakage before those happen. This study suggests how to prevent for the damage from leaked confidential information throughout building the DRM monitoring process which can predict employee's resignation.

Design and Implementation of DB Protection System through Critical Query Signature (핵심 쿼리 결제를 통한 DB 보호 시스템 설계 및 구현)

  • Kim, Yang-Hoon;Kwon, Hyuk-Jun;Lee, Jae-Pil;Park, Chun-Oh;Kim, Jun-Woo;Chang, Hang-Bae
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.2
    • /
    • pp.228-237
    • /
    • 2011
  • The risk of leakage or theft of critical data which is stored in database is increasing in accordance with evolution of information security paradigm. At the same time, needs for database security have been on the rapid increase due to endless leakage of massive personal information. The existing technology for prevention of internal information leakage possesses the technical limitation to achieve security goal completely, because the passive control method including a certain security policy, which allows the only authorized person to access to DBMS, may have a limitation. Hence in this study, we propose Query Signature System which signatures the queries accessing to the critical information by interrupting and passing them. Furthermore this system can apply a constant security policy to organization and protect database system aggressively by restricting critical query of database.