TCP/IP Protocol을 이용한 원격 감시용 계측 시스템 개발에 관한 연구 (A Study of Development of a Remote Monitoring Data Acquisition System using TCP/IP Protocol)

  • 문경록;이주열;김재문
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.173-176
    • /
    • 2002
  • DAS(Data Acquisition System) as a ground support equipment has played a critical role in proving the status of ready-to-fire of a rocket system before launch. But it is hard to implement and place a real-time measuring system in a control room at a long distance from the vehicle. In this paper DAS is introduced by being located at the LEC(Launch Equipment Container)[1], 50 meters away from the rocket and connected to remote monitoring system via fiber optics with TCP/IP protocol by means of client/server algorithm. Therefore real-time data acquisition and storage are guaranteed and a convenient and useful MMI (Man-Machine Interface) can be developed.

  • PDF

원전 Data Acquisition System 설계 (Design of Nuclear Power Plant Data Acquisition System)

  • 정철환;김정택;이동영;함창식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.253-256
    • /
    • 1988
  • 원자력발전소의 운전현황감시 및 안전성확보를 위해 원전에 비상대응설비등을 설치 할려고 하는 상황에서 본 연구는 이런 원전설비 시스템의 입력단이 되는 DAS(Data acquisition System)를 설계, 제작하므로 원전설비에 대한 기술자립을 향상시켰다. 여기서 연구된 DAS는 현장신호를 격리 및 분리하고 analog와 digital 신호를 취득하며 Non Class-1E analog 80개, digital 신호 16개와 Class-1E analog 신호 2개, digital 신호 4개를 취급할수있도록 설계하였다. 여기서 설계된 DAS는 원전의 안전정보 system이나 기타 process의 monitoring system의 입력단으로 적용 가능한 시스템이다.

  • PDF

Optimization of Data Acquisition System with Parallel Collection for PET

  • Yoshida, Eiji;Shimizu, Keiji;Murayama, Hideo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.311-313
    • /
    • 2002
  • We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this scanner, a maximum data transfer rate of coincidence pair's event information is 10 Mcps and one event is a 64-bit data format. This maximum data transfer rate corresponds by 10 times a conventional PET scanner. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Data transfer rate is improved by optimizing parameters of a message size, and so on.

  • PDF

국방무기체계 획득절차 발전방향 - 미국 국방획득절차 개선노력을 중심으로 - (A Study for Defense Acquisition System Improvement)

  • 고심재
    • 한국국방경영분석학회지
    • /
    • 제31권2호
    • /
    • pp.86-104
    • /
    • 2005
  • During the 'Cold War', DoD had focused on the high performance and timely acquisition which enabled quick field out the superior weapons than the enemy regardless of acquisition cost. But, after the cold war, the focus has been changed to the 'cost effective acquisition' of weapon systems because of tremendous investment cost & economic theory. The U.S. DoD has been tried to make 'the most effective acquisition system'(AR, Acquisition Reform) from mid-80's with their enough experienced program data, and as a result, they had launched the new acquisition procedure - DoD 5000 series - in 1996. DoD is continuously doing the study and making several improvements on the procedure after it had been once announced. On Oct 30. 2002, DoD noticed that they cancelled the DoD 5000 series documents(5000.1, 5000.2, 5000.2-R) and 5000.2-R will be reissued as a guide. The most recent version which focused on 1) evolutionary acquisition and spiral development, 2) procedure for future technology systems including software and IT, 3) supplement on the area of efficiency, flexibility, creativity and innovation of old system was issued by May 12. 2003. This article suggests a 'good idea' based on the reviewing of these DoD efforts for our defense acquisition regulation and procedure to go. It includes the CAIV concept application, IPT utilization, T&E method, cost or price based contract etc-all for the effective acquisition.

마이크로 프로세서에 의한 측정기 (The Design of General Purpose Data Acquisition System)

  • Myoung-Sam Ko;Wook-Hyun Kwon;Dong-Il Kim
    • 대한전기학회논문지
    • /
    • 제32권9호
    • /
    • pp.305-314
    • /
    • 1983
  • This paper presents a general purpose data acquisition system based on the microprocessor system with M 6800. instrument and lograrithmic amplifiers and A/D converters are used to implement a signal conditioner for a various kinds of signals. The proposed system has a function such that the processor may select the one of the input signals as will and also it is proved that the system may control the control signal and digital converted signal through I/O port of PIA. Practical measurement by the proposed system shows in good results.

  • PDF

디지털 측정 및 분석장치의 적용에 관한 연구 (Consideration on data acquisition and analysis system for using short-circuit tests)

  • 김맹현;서윤택;김대원;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.38-40
    • /
    • 2001
  • Measuring technology based on the computer and software is used worldwideiy by the aids of remarkably improved digital technology and measuring devices, and the electro- magnetic interference due to high currents and high voltages is being solved by the helps of applied optic instrumentation technology. The automatic acquisition, analysis and storage system of test data is available for utilizing the numerical computation technology. The measuring accuracy and testing efficiency are thus much higher because of the developed technologies. In this paper, the construction of data acquisition system in KERI including measuring devices and its application to the short circuit test are described, and additionally the algorithm of the analyzing program for the automatic process of test data and the results of analyses are described.

  • PDF

일반적으로 쓰이는 데이타 취득장치의 제작 (Construction of a General Purpose Data Acquisition System)

  • 황의진;김하석
    • 대한화학회지
    • /
    • 제31권1호
    • /
    • pp.71-78
    • /
    • 1987
  • 화학실험실에서 일반적으로 쓸 수 있는 간단하고 값이 비싸지 않은 데이타취득 장치를 제작하였다. 이 장치는 12-bit 4K 메모리를 내장하고 있기 때문에 독자적으로 빠른 신호를 잡을 수 있다. 또 데이타의 취득과 처리에는 Apple Ⅱ+ 개인용 컴퓨터와 연결하여 쓸 수도 있다.

  • PDF

FPGA를 이용한 전차선로 실시간 계측시스템 구현 (Implementation of FPGA-Based Real-Time data acquisition system for overhead contact wire)

  • 나해경;박영;조용현;정호성;박현준;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.531-532
    • /
    • 2006
  • This paper presents the implementation of Real-time data acquisition system for dynamic characteristics of overhead contact wire in electric railway. The reconfigurable field-programmable gate array (FPGA) and LabVIEW graphical development tools have been used to Real-time monitoring system. The results from a field test show that the proposed technique and developed system can be practically applied to measure the assessment quantity or quantities on overhead contact lines for the online real-time process monitoring.

  • PDF

DATA ACQUISITION METHOD USING A SMARTPHONE ON CONSTRUCTION SITE

  • Ahra Jo;Teahoon Kim;Hunhee Cho;Kyung-In Kang
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.231-234
    • /
    • 2013
  • According to the recent development of USN technology, it has been applied in various fields of construction management. In particular, the concrete curing management using the wireless measurement system is actively being conducted. However, the existing method has limitations such as the reinstallation of temperature sensors and repositioning of repeaters. It is also not easy to acquire the measured data. Thus, this study focuses on the concrete curing management. This study proposes data acquisition method using the smartphone on construction site and tests applicability of the data measuring device and the smartphone. The test allows us to suggest the actual communication distance on construction site and to determine the correction value that is applied to the measured temperature. The data acquisition method proposed in this study is intended to enable appropriate management on construction site and will be able to be applied effectively to a variable construction site. It can also be used in all fields of construction management.

  • PDF

다채널 다중신호 데이터 획득 시스템의 구현에 관한 연구 (A Study on the Implementation of a Data Acquisition System with a Large Number of Multiple Signal)

  • 손도선;이상훈
    • 한국지능시스템학회논문지
    • /
    • 제20권3호
    • /
    • pp.326-331
    • /
    • 2010
  • 본 논문에서는 제조 장비를 위한 다채널 다중신호 데이터 획득 시스템의 설계와 구현에 대해 다룬다. 제안된 시스템은 800 채널의 아날로그 신호를 처리 할 수 있으며, 알테라 쿼터스 툴을 활용하여 Cyclone II FPGA로 구현되었다. 구현된 시스템은 공작기계와 같은 제어장치의 대규모 입출력 라인들의 올바른 동작여부를 판정하는데 적합하다. 그 시스템은 데이터 처리량을 줄일 수 있는 제어부, 전압분배회로 및 USB 인터페이스로 구성된다. 데이터 처리량을 줄이기 위하여 획득한 데이터를 비교 분석하여 동일한 데이터를 분리해내고 변화가 있는 데이터만을 전송하는 방법의 알고리즘을 적용하였다. 제조장비에 적용된 시험결과는 짧은 시간 내에 800개의 아날로그 입력 신호들을 획득 처리한 후 적절히 전송함을 보여준다.