• 제목/요약/키워드: Data Acquisition Equipment

검색결과 201건 처리시간 0.027초

랜설비에 유기되는 이상전압의 주파수분석을 통한 서지의 검출 (Detection of Surges by Frequency Analysis on Lan Equipment)

  • 허창수;이세현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.213-215
    • /
    • 2001
  • We investigated the frequency characteristics of surges induced on Lan equipments by using V-F converter. which installed on the second part of protection system. We stored and analyzed the frequency converting data with the amplitude of overvoltage. In addition. The data acquisition system was made so that we could be examine the results wave through WEB. From this results, it is found that this frequency analysis could be helped for design and protection of various undesired surges.

  • PDF

Rapid Local Modeling in Construction Automation

  • 권순욱
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.173-179
    • /
    • 2003
  • Techniques to rapidly model local spaces, using 3D range data can enable implementation of: (1) real-time obstacle avoidance for improved safety, (2) advanced automated equipment control modes, and (3) as-built data acquisition for improved quantity tracking, engineering, and project control systems. The objective of the research reported here was to introduce current rapid local modeling techniques and develop rapid local spatial modeling tools.

  • PDF

전기기기 절연열화진단 시스템개발에 관한 고찰 (Study on Development of Insulation Degradation Diagnosis System for Electrical System)

  • 김이곤;유권종;김서영;조용섭;박봉서;최시영;심상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.231-235
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D Patterns from analyzing it. For fettering the noise contained in sensor signals we used ICA algorithms. Using this data design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

핵의학 투고 논문 분류 및 방향성 고찰 (Classification of submitted nuclear medicine dissertation and directional consideration)

  • 조호연;우영란;서강록;홍건철
    • 핵의학기술
    • /
    • 제26권2호
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

비젼시스템을 이용한 토양미생물 관측장비 개발 (Development of Observation Equipment for Soil Microorganisms Using Vision System)

  • 김일배;홍원학;이학성;서명교;서정호
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.108-114
    • /
    • 2004
  • Observation of microorganisms collected from contaminated soils has been mainly conducted by using microscopy. Microscopic measurement is occupied an important part of the microorganism experiment, and is used as an important tool to count microorganisms as well as to observe cellular form and mode of life in the field of soil microbe observation. In general, observation equipments for soil microbes consist of electron microscope, camera, frame grabber (image acquisition baud), and image analysis software. Because image analysis software should be linked with frame grabber most equipments have to be imported as the package form. Therefore, the observation system is very expensive and difficult to be operated. In this study, soil microbes' observation equipment with the vision system which is easy operated and cheaper than imported one was developed and tested. The efficiency of image capturing and data aquisition with developed frame grabber and software in this experiment was good enough to analyze the image of soil microorganism.

중장비용 유압구동형 수퍼차져의 유동특성 (Flow Characteristics of Hydraulic Driven Super-Charger for Heavy Equipment)

  • 김봉환;문철진
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this study is to investigate the actual field application of the super-charger for heavy equipment. In this paper, the numerical analysis and performance evaluating experiments were performed. ANSYS CFX program has been used to obtain the solutions for the problems of three-dimensional turbulent air flow in the super-charger. To evaluate the flow performance of the super-charger, the performance test facility and data acquisition system were manufactured. We obtained satisfactory results from CFD analysis and flow experiment.

연구용 건물의 열원 및 공조기기의 에너지 소비량 측정 및 분석 (Measurement and Analysis of Energy Consumption of HVAC Equipment of a Research Building)

  • 김성실;김영일
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.914-922
    • /
    • 2004
  • In this study, measurement and analysis of energy consumption of a research building have been conducted. The energy audit procedure includes monitoring of electricity and LNG consumption over a period of three yews from 2000 to 2002. Data acquisition system for collecting energy consumption data of HVAC equipment such as chillers, fan filter units, AHUs, cooling towers, boilers, pumps, fan coil units, air compressors and etc. has been installed in a building located in Seoul. Data collected at an interval of 1 minute are analyzed for studying the energy consumption pattern of a research building. Percentage of energy consumption of all HVAC equipment is $51.0\%$ in 2000, $55.4\%$ in 2001, and $62.3\%$ in 2002, respectively. Electricity consumption of chillers accounts for $17.6\%$ of the total energy consumption, which is the largest. Annual energy consumption-rate per unit area is $840.5Mcal/m^2{\cdot}y$ in 2000, $1,064.8Mcal/m^2{\cdot}y$ in 2001, and $1,393.0Mcal/m^2{\cdot}y$ year 2002, respectively.

Impact of Marketer Capabilities and Marketer Persistence on Marketer Performance and Distribution of Agricultural Product Equipment: Evidence from East Java, Indonesia

  • Herry KRISTANTO;Margono SETIAWAN;Sunaryo;Dodi Wirawan IRAWANTO
    • 유통과학연구
    • /
    • 제21권9호
    • /
    • pp.35-42
    • /
    • 2023
  • Purpose: The research aims at examining the impact of marketer capabilities and persistence on marketer performance and distribution of agricultural product facilities. Research design, data, and methodology: The research employs quantitative methods using a cross-sectional design survey by analyzing the marketer of agricultural production facilities. Sampling was done using the purposive sampling technique and data were taken from 235 respondents. The data were then processed using SEM-PLS. Results: The findings reveal that both marketer capabilities and marketer persistence significantly impact the performance of agricultural product facility marketers. Notably, marketer persistence exerts a more dominant influence on marketer performance than marketer capabilities. Effective communication and coordination between the sales team and the distribution center emerge as crucial factors determining the success of distributing agricultural equipment to reach farmers' land at the optimal time. Conclusions: The findings offer valuable managerial insights for agricultural product facility companies seeking to enhance marketer performance. To achieve this, companies should focus on increasing marketer persistence, with an emphasis on nurture-focused persistence rather than closure-focused persistence. Additionally, improving marketer capabilities is crucial, starting with relationship development, followed by trust building, customer retention, responsiveness, and acquisition. These strategies can collectively contribute to boosting marketer performance within the organization.

데이터 통합을 위한 장비모니터링시스템 설계 및 구현 (Design and Implementation of Equipment Monitoring System for Data Integration)

  • 곽우영;김우성;박근덕
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권9호
    • /
    • pp.115-126
    • /
    • 2009
  • 생산현장에서 장비에서 발생하는 데이터들을 관리하는 것은 매우 중요한 일이다. 그러나 이러한 데이터에 대한 체계적 관리는 제한적으로 이루어지고 있다. 본 논문에서는 장비에서 발생하는 데이터의 수집을 편리하게 하고 유실 데이터의 처리를 원활하게 하며, 유지보수와 시스템의 확장성이 편리한 새로운 미들웨어 모니터링 시스템을 제안한다. 본 논문의 결과를 활용하면 장비와 기계로부터 얻은 데이터를 데이터베이스에 저장하고 이를 통하여 효율적으로 장비 상황을 실시간 모니터링 할 수 있다. 또한 XML 데이터로 저장함으로써 다른 시스템에서도 쉽게 재 사용할 수 있도록 상호 운용성을 강화할 수 있다. 특히, SAP(Systems, Applications and Products in Data Processing)과의 연계를 편리하게 할 수 있으며 간소화된 비즈니스로직의 구현으로 시스템을 경량화하여 백업 시스템의 확장성 및 유지 보수 특성을 강화시킨다.

도시철도 차단기 동작특성 검출장치 구성에 관한 고찰 (The study of Detection System Constuction For Urban Transit Circuit Breaker Motion Characteristic)

  • 임형길;유기선;이기승
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.95-95
    • /
    • 2010
  • Because of the environmental matters the importance of the city railroad is as time goes by increasing. The case of obstacle of the power equipment which supplies electric power to city railroad will occur social and economical enormous loss. Thus, I studied on the preventing method in advance which makes it possible for us to maintain facilities efficiently. The main check points of the power facilities are voltage, current, humidity, partial discharge, move current. These points are gathered by sensor and transmitting to data acquisition device. These data are used to check equipment status in real time. In this paper I described in brief test process and results of the detection system.

  • PDF