The Assesment of Electric Shock Rate of Low Voltage Joint-Box Based Submerged Condition (침수조건에 따른 저압 지중함의 감전 위험성 평가)

  • Shim, Keon-Bo;Kim, Kung-Chul;Kim, Han-Sang;Kim, Jong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.265-270
    • /
    • 2007
  • The potential and step voltage distribution around low voltage joint-box cover were simulated with the variation of resistivity of water, depth of submerged water and point of leakage current. The potential distribution is very high gradient around low voltage joint-box, this condition is very dangerous states.

  • PDF

PD Characteristics of inverter-fed AC motor subjected to impulse voltage in electric train (전동차내 임펄스 전압인가에 따른 인버터구동형 유도전동기의 PD 특성)

  • Lee, Kang-Won;Kim, Ryong-Myung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.564-565
    • /
    • 2005
  • AC induction motor equipped in electric train is driven by VVVF inverter which produces switching pulse like impuse. Impulse voltage is more dangerous than continuous alternative voltage for the insulating performance of AC induction motor. This paper has investigated PD characteristics caused by impuse voltage for stator coils inserted in AC induction motor.

  • PDF

A Study on the Pressure Sensor for the Direct Detection of the Approach to the Dangerous Power Facilities Using Pb-free BNKT Ceramics (무연 BNKT 세라믹스를 이용한 위해(危害)전력설비 접근 직접감지용 압력센서에 관한 연구)

  • Hong, Jae-Il;Yoo, Ju-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.31-34
    • /
    • 2006
  • A infrared rays sensor or ultrasonic sensor can detect the object at the narrow area, however a pressure sensor can detect man and animal at the wide area. It is necessary to manufacture the sensor by using Pb-free ceramics in the respect of environmental protection. Piezoelectric properties of ceramics added 0.2wt% $La_2O_3\;into\;0.96Bi_{0.5}(Na_{0.84}K_{0.16})_{0.5}+0.04SrTiO_3$ were 0.4 of kp, $31{\times}$10^{-3}Vm/N\;of\;g_{33}$. The output voltage of the pressure sensor is 0.48 V at 20 in$H_2O$. The output voltage of the pressure sensor with driving circuit is 9.8 V, 37 ms width.

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

Evaluations of Dangerous Voltages around Grounding Electrode using Small-sized Model (축소모델을 이용한 접지전극 주변의 위험전압 평가)

  • Baek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • In this paper, to propose a valid method solving a problem relevant to grounding from actual field data, the experimental results relevant to touch and step voltages and surface potential profiles measured around the real-sized and small-sized grounding electrode models were described. The ground surface potential profiles and dangerous voltages around the concrete pedestals employed in street facilities such as street lamps, traffic signal lamp and controllers as a case study were measured and discussed. The hemispherical cell with a diameter of 1,160[mm] was employed to simulate uniform soil. As a result, the results measured with the small-sized model were in reasonably agreement with the data obtained from the real-sized installation. It was found that the small-sized model test could be employed as a useful means evaluating the dangerous voltages around grounding electrodes installed at the inaccessible areas such as mountains, underground, underwater, and so on.

An Improved Model for Grounding System Using process of Grounding Design (접지설비 절차에 따른 개선된 접지실비 모델)

  • Song, Young-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.50-60
    • /
    • 2008
  • The ANSI/IEEE Std. 80-2000 method has been commonly used to design grounding system for the South Korea domestic market. However, the appropriateness of this method to the ground design environment has not yet been examined. This paper presents a new design grounding system method that complements the ANSI/IEEE Std. 80-2000 method, when the new method is a lied to thickness, dangerous voltage, and grid spaced computations for grounding conductors. Furthermore, this paper examines reliability and economic efficiency issues by comparing of the ANSI/IEEE Std. 80-2000 Annex B's case study with the original method.

Framework Design of Voltage Security Assessment(VSA) using QSS Analysis method (QSS 해석 기법을 이용한 Voltage Security Assessment(VSA) 프로그램 기반설계)

  • Hur, Jin;Lee, Sang-Ho;Kim, Tae-Hyun;Moon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.12-14
    • /
    • 2005
  • Security problem has been a fundamental issue in the operation and planning of power system. Voltage instability is widely recognized as an important issue of power system blackout. As far as real-time operation is concerned, there is a need for appropriate tools to identify dangerous contingencies, assess security margins and suggest corrective actions. In this paper, we propose the framework design of Voltage Security Assessment(VSA) using QSS(Quasi Steady-State) analysis method in order to implement fast time domain simulation engine as a major part of VSA.

  • PDF

A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis (개인용 저주파 자극기의 특성분석 및 Prototype개발)

  • Lee, Gi-Song;Lee, Dong-Ha;Yu, Jae-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

A Power Line Proximity Detecter for Mobile Crane (크레인의 고압 전선로 접근 경보장치)

  • Choi, Sam-Jin;Kim, Hyun-Sik;Lee, Jong-Ho;Kim, Il-Hwan;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2374-2376
    • /
    • 2001
  • In this paper we have developed a Power Line Proximity Detecting device for Mobile Crane by using a Derivation Electric-Potential Detection method. A mobile crane worker can be easily exposed to a dangerous electrical shock and the electrocution while they are working at near the high-voltage electrical lines. The derivation electric-potential of the power lines have been simulated in our experiment, Also, microprocessor-based detecting device and transmitter/receiver modules are introduced to show a solution for the dangerous mobile crane working environment. As a result, It has been shown a good functional field test.

  • PDF

Analysis of PD signals according to defects of the piezoelectric sensor (압전 센서 제작 및 결함에 따른 PD 분포 분석)

  • Jung, Hae-Eun;Park, Seong-Hee;Kang, Seong-Hwa;Lim, Kee-Joe;Lee, Kang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1480-1481
    • /
    • 2006
  • It is very difficult and dangerous to measure partial discharge from high voltage equipment in outdoor situation. But that is very important thing for preventing serious accidents from defects which originated in insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor detect PD signals without direct electrical connection between sensor and high power equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal showed good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulse.

  • PDF