• 제목/요약/키워드: Dampers

검색결과 1,030건 처리시간 0.021초

An innovative hardware emulated simple passive semi-active controller for vibration control of MR dampers

  • Zhang, Jianqiu;Agrawal, Anil K.
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.831-846
    • /
    • 2015
  • Magneto-Rheological (MR) dampers are being used increasingly because of their adaptability to control algorithms and reliability of passive systems. In this paper, an extensive investigation on performance of MR dampers in semi-active and passive modes has been carried out. It is observed that the overall energy dissipation by MR dampers in passive-on modes is higher than that in semi-active modes for most of the competitive semi-active controllers. Based on the energy dissipation pattern, a novel semi-active controller, termed as "Simple Passive Semi-Active Controller", has been proposed for MR dampers. This controller can be emulated by a simple passive hardware proposed in this paper. The proposed concept of controller "hardware emulation" is innovative and can also be implemented for other semi-active devices for control algorithms of certain form. The effectiveness and reliability of the proposed controller has been investigated extensively through numerical simulations. It has been demonstrated that the proposed controller is competitive to or more effective than other widely used / investigated semi-active controllers.

20층 비선형 벤치마크 빌딩에 대한 자기유변유체 감쇠기의 최적위치 결정 (Optimal placement of MR dampers for 20-story nonlinear benchmark building)

  • 장종우;조상원;이인원;윤우현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.467-472
    • /
    • 2003
  • The objective of optimal placement of dampers for a structure is to maximize the effectiveness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for MR dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor we. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et at. 2000, 2002). Passive On/Off algorithms are used in order to represent the control algorithm of MR dampers.

  • PDF

Seismic retrofitting of steel moment-resisting frames (SMRFs) using steel pipe dampers

  • Ali Mohammad Rousta
    • Structural Engineering and Mechanics
    • /
    • 제87권1호
    • /
    • pp.69-84
    • /
    • 2023
  • The use of steel pipe dampers (SPD) as fuses or interchangeable elements in the steel moment-resisting frames (MRF) is one of the newest methods for improving seismic performance. In the present study, the performance of steel pipe dampers in MRF has been investigated. Evaluation of MRF with and without SPD models were performed using the finite element method by ABAQUS. For validation, an MRF and MRF with steel pipe dampers were modeled that had been experimentally tested and reported in previous experimental research and a good agreement was observed. The behavior of these dampers in frames of 3, 6, and 9 stories was studied by modeling the damper directly. Nonlinear time history dynamic analysis was used. It was observed that by increasing the number of stories in the buildings, steel pipe dampers should be used to perform properly against earthquakes. The installation of steel pipe dampers in steel moment-resisting frames shows that the drift ratio between the floors is reduced and the seismic performance of these frames is improved.

Improved seismic performance of steel moment frames using rotational friction dampers

  • Ali Banazadeh;Ahmad Maleki;Mohammad Ali Lotfollahi Yaghin
    • Earthquakes and Structures
    • /
    • 제25권4호
    • /
    • pp.223-234
    • /
    • 2023
  • The use of displacement-dependent rotational friction dampers (RFD) as fuses or interchangeable elements in the moment-resisting frames (MRF) is one of the newest methods for improving seismic performance. In the present study, the performance of rotational friction dampers in MRF has been investigated. Evaluation of MRF with and without RFD models was performed using the finite element method by ABAQUS. For validation, an MRF and MRF with rotational friction dampers were modeled that had been experimentally tested and reported in previous experimental research and a good agreement was observed. The behavior of these dampers in frames of 3-, 6-, and 9-story was studied by modeling the damper directly. Nonlinear time history dynamic analysis was used. It was observed that by increasing the number of stories in the buildings, rotational friction dampers should be used to perform properly against earthquakes. The installation of rotational friction dampers in steel moment-resisting frames shows that the drift ratio between the floors is reduced and the seismic performance of these frames is improved.

Dynamic analysis of frames with viscoelastic dampers: a comparison of damper models

  • Lewandowski, R.;Bartkowiak, A.;Maciejewski, H.
    • Structural Engineering and Mechanics
    • /
    • 제41권1호
    • /
    • pp.113-137
    • /
    • 2012
  • Frame structures with viscoelastic (VE) dampers mounted on them are considered in this paper. It is the aim of this paper to compare the dynamic characteristics of frame structures with VE dampers when the dampers are modelled by means of different models. The classical rheological models, the model with the fractional order derivative, and the complex modulus model are used. A relatively large structure with VE dampers is considered in order to make the results of comparison more representative. The formulae for dissipation energy are derived. The finite element method is used to derive the equations of motion of the structure with dampers and such equations are written in terms of both physical and state-space variables. The solution to motion equations in the frequency domain is given and the dynamic properties of the structure with VE dampers are determined as a solution to the appropriately defined eigenvalue problem. Several conclusions concerning the applicability of a family of models of VE dampers are formulated on the basis of results of an extensive numerical analysis.

Simultaneous optimal damper placement using oil, hysteretic and inertial mass dampers

  • Murakami, Yu;Noshi, Katsuya;Fujita, Kohei;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제5권3호
    • /
    • pp.261-276
    • /
    • 2013
  • Oil, hysteretic and inertial mass dampers are representatives of passive dampers used for smart enhancement of seismic performance of building structures. Since oil dampers have a nonlinear relief mechanism and hysteretic dampers possess nonlinear restoring-force characteristics, several difficulties arise in the evaluation of buildings including such dampers. The purpose of this paper is to propose a practical method for simultaneous optimal use of such dampers. The optimum design problem is formulated so as to minimize the maximum interstory drift under design earthquakes in terms of a set of damper quantities subject to an equality constraint on the total cost of dampers. The proposed method to solve the optimum design problem is a successive procedure which consists of two steps. The first step is a sensitivity analysis by using nonlinear time-history response analyses, and the second step is a modification of the set of damper quantities based upon the sensitivity analysis. Numerical examples are conducted to demonstrate the effectiveness and validity of the proposed design method.

Design of MR dampers to prevent progressive collapse of moment frames

  • Kim, Jinkoo;Lee, Seungjun;Min, Kyung-Won
    • Structural Engineering and Mechanics
    • /
    • 제52권2호
    • /
    • pp.291-306
    • /
    • 2014
  • In this paper the progressive collapse resisting capacity of steel moment frames with MR dampers is evaluated, and a preliminary design procedure for the dampers to prevent progressive collapse is suggested. Parametric studies are carried out using a beam-column subassemblage with varying natural period, yield strength, and damper force. Then the progressive collapse potentials of 15-story steel moment frames installed with MR dampers are evaluated by nonlinear dynamic analysis. The analysis results of the model structures showed that the MR dampers are effective in preventing progressive collapse of framed structures subjected to sudden loss of a first story column. The effectiveness is more noticeable in the structure with larger vertical deflection subjected to larger inelastic deformation. The maximum responses of the structure installed with the MR dampers designed to meet a given target dynamic response factor generally coincided well with the target value on the conservative side.

Seismic study of buildings with viscoelastic dampers

  • Pong, W.S.;Tsai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제3권6호
    • /
    • pp.569-581
    • /
    • 1995
  • In this paper, the seismic behavior of a 10-story building equipped with viscoelastic dampers is analyzed. The effects of ambient temperature, the thickness, the total area, and the position of the viscoelastic dampers are studied. Results indicate that the energy-absorbing capacity of viscoelastic damper decreases with increasing the ambient temperature. The thickness and the total area of viscoelastic dampers also affect the seismic mitigation capacity. The thickness cannot be too small, which is not effective in vibration reduction, nor can it be too large, which not only increases the cost but also reduces the seismic resistance. The total area of viscoelastic dampers should be determined properly for optimum damper performance at the most economical design. The mounting position of viscoelastic dampers also influences the structure's seismic performance. Numerical results show that, if properly equipped, the VE dampers can reduce the structural response both floor displacement and story shear force and increase the overall level of damping in structures during earthquakes.

Frequency analysis of beams with multiple dampers via exact generalized functions

  • Failla, Giuseppe
    • Coupled systems mechanics
    • /
    • 제5권2호
    • /
    • pp.157-190
    • /
    • 2016
  • This paper deals with frequency analysis of Euler-Bernoulli beams carrying an arbitrary number of Kelvin-Voigt viscoelastic dampers, subjected to harmonic loads. Multiple external/internal dampers occurring at the same position along the beam axis, modeling external damping devices and internal damping due to damage or imperfect connections, are considered. The challenge is to handle simultaneous discontinuities of the response, in particular bending-moment/rotation discontinuities at the location of external/internal rotational dampers, shear-force/deflection discontinuities at the location of external/internal translational dampers. Following a generalized function approach, the paper will show that exact closed-form expressions of the frequency response under point/polynomial loads can readily be derived, for any number of dampers. Also, the exact dynamic stiffness matrix and load vector of the beam will be built in a closed analytical form, to be used in a standard assemblage procedure for exact frequency response analysis of frames.

횡하중에 대한 점성 및 점탄성감쇠기의 진동제어성능의 비교 (Comparison of Motion Control Capacity of Viscous and Viscoelastic Dampers for Lateral Loads)

  • 김진구;김유경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.155-162
    • /
    • 2001
  • In this study a structure with viscoelastic and viscous dampers with identical damping coefficient subjected to stationary seismic and wind load were analyzed in time and frequency-domain to compare motion control capability of viscous and viscoelastic dampers. The dampers were placed based on story drift and acceleration obtained from RMS responses. According to the analysis results, the motion control capability of viscous dampers turned out to be superior to that of the viscoelastic dampers for the case of seismic load. On the contrary, in case of wind load, the viscoelastic dampers were more effective in the mitigation of dynamic responses. However, it was also found that the differences were in a narrow margin.

  • PDF