• 제목/요약/키워드: Damage parameters

검색결과 1,537건 처리시간 0.031초

New ecological health assessment approaches of an urban stream using molecular and physiological level biomarkers and bioindicators

  • Kim, Ja-Hyun;Yeom, Dong-Hyuk;Kim, Joon-Ha;An, Kwang-Guk
    • Animal cells and systems
    • /
    • 제16권4호
    • /
    • pp.329-336
    • /
    • 2012
  • This study evaluated ecological health, using various biomarkers and bioindicators, of pale chub (Zacco platypus) as a sentinel species, in Daejeon Stream, South Korea, during AprilMay 2011. The biomarkers and bioindicators were compared among three sites of control: Reference ($C_z$), transition ($T_z$), and the urban zones ($U_z$); and the 7-Ethoxyresorufin-O-deethylase (EROD) activity, DNA damage, acetylcholinesterase (AChE) activity, and vitellogenin (VTG) concentrations were more significantly increased in the $U_z$ than in the $C_z$. Also, physiological markers such as condition factor, liver somatic index, visceral somatic index, and gonad somatic index were significantly increased in the $U_z$ than in the $C_z$. For the health assessments, three categorized parameters of blood chemistry, molecular biomarkers, and physiological bioindicators were standardized and calculated as a star-plot, representing values of Integrated Health Response (IHR). Values of IHR had more significant (P<0.05) increases in the $U_z$ than any other zones, indicating an impairment of ecological health by organic matter, nutrients (N, P), and toxic chemicals. This study is based on low levels of biological organization approach of molecular and physiological biomarkers and bioindicators, so further study of high-levels of biological organization approach such as community and population is required for overall range of health assessments. The approach of IHR values, however, may be useful in providing early warning of future impacts on ecological health.

중성자 조사 및 열처리에 따른 SA508 C1.3강의 자기특성 변화

  • 장기옥;김택수;심철무;지세환;김종오
    • 한국자기학회지
    • /
    • 제8권5호
    • /
    • pp.249-254
    • /
    • 1998
  • 자기측정법에 의한 조사손상 평가 가능성을 조사하기 위하여 SA508 CI.3강 모재금속의 중성자 조사 및 열처리 온도에 따른 자기특성(자기이력곡선, Barkhausen Noise(BN) 진폭, BN 에너지)과 경도 변화를 측정 비교하였다. 중성자 조사에 따라 자화율, BN 진폭, BN 에너지는 감소하였고 보자력과 경도는 증가하였으며, 포화자화 값은 변화하지 않았다. 열처리된 조사시편의 경우, 열처리 온도 증가에 따라 BN 에너지는 증가하였으며, 경도는 감소하였다. 결함과 전위혹은 자벽 이동과의 상호작용에 의한 경도 및 자기특성의 일관성 있는 변화는 원자로 압력용기 재료의 조사손상 평가와 관련 자기적 측정법 응용 가능성을 보여주었다.

  • PDF

물순환 건전화 대안 적용을 위한 안양천의 속성별 가치추정 (Estimating Attributes Value of Alternatives Applied for Rehabilitation of Hydrologic Cycle of the Anyangcheon Watershed)

  • 공기서;정은성;이길성;유진채
    • 한국수자원학회논문집
    • /
    • 제39권12호
    • /
    • pp.1031-1042
    • /
    • 2006
  • 최근 유역과 하천개발사업에 대한 관심이 높아지고 있다. 이러한 배경하에서 본 논문은 실험선택법(choice experiment)을 적용하여 안양천의 속성별 가치를 추정하고 추정된 가치를 적용하여 안양천 물순환 건전화를 위한 대안의 경제적 가치를 추정하였다. 실험선택법은 여러 속성으로 구성된 환경재의 가치추정방법으로 응답자의 선호체계에 명확하게 초점을 둔 지불의사 유도방법이다. 예비조사를 통해 안양천이 가진 속성을 홍수피해위험, 유지유량, 수질, 하천형태, 안양천 개선분담금으로 설정하였다. 서울시와 경기도 지역 거주민 200명을 설문조사하였고 조건부로짓 모형을 적용하여 각 속성에 따른 수준별 가구당 매월 잠재가치를 추정하였다. 본 논문은 정책결정자들에게 하천개발 사업과 관련한 의사결정과정에 유용한 방법론적 체계와 정량적 정보를 제공할 것으로 기대된다.

Advantages of anterior inferior alveolar nerve block with felypressin-propitocaine over conventional epinephrine-lidocaine: an efficacy and safety study

  • Shinzaki, Hazuki;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제15권2호
    • /
    • pp.63-68
    • /
    • 2015
  • Background: Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Methods: Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. Results: The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was $233{\pm}37min$, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). Conclusions: The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain.

지능형 복합재 구조물에 대한 광섬유센서의 적용에 관한 연구 (A study on the application of optical fiber sensors to smart composite structures)

  • 장태성;김호;이정주
    • 센서학회지
    • /
    • 제5권6호
    • /
    • pp.15-24
    • /
    • 1996
  • 본 연구에서는 광섬유센서를 지능형 복합재 구조물에 적용하기 위한 기초적 연구의 일부로서, 구조물내에서의 광섬유센서의 건전성 평가와 주조물에 유발된 변현 및 손상에 대한 광섬유센서의 신호검출 거동을 연구 검토하였다. 첫째로, 최약체결파손이론에 거한 광섬유센서의 누적파손분포를 비교하고 수정계수를 도입함으로써, 굽힘시험이 인장시험을 대신할 수 있음을 보였다. 실험에 의해 Weibull 파라미터를 얻고, 굽힘시험에서 유도된 누적파손분포에 적용될 수정계수를 구했다. 열처리한 강섬유센서와 열처리하지 않은 광섬유센서의 인장강도 평균값을 비교함으로써 복합재료 적층관의 경화 사이클 동안 열처리에 의해 야기되는 광섬유센서의 건전성을 평가하였다. 둘째로, 직교적층판과 일방향적층판의 인장시험에서 측정된 시편의 응력-변형률과 삽입된 광섬유센서를 통과한 레이저신호 세기와의 관계를 검토하고, 광섬유센서를 이용한 효과적 손상검출 가능성을 연구 검토하였다.

  • PDF

로드/언로드 성능향상을 위한 서스팬션의 구조최적화 (Integrated Optimal Design for Suspension to Improve Load/Unload Performance)

  • 김기훈;손석호;박경수;윤상준;박노철;양현석;최동훈;박영필
    • 정보저장시스템학회논문집
    • /
    • 제2권2호
    • /
    • pp.130-137
    • /
    • 2006
  • The HDD(hard disk drive) using Load/unload(L/UL) technology includes the benefits which are increased areal density, reduced power consumption and improved shock resistance than those of contact-start-stop(CSS). It has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. The main objects of L/UL are no slider-disk contact or no media damage. For realizing those, we must consider many design parameters in L/UL system. In this paper, we focus on lift-off force. The 'lift-off' force, defined as the minimum air bearing force, is another very important indicator of unloading performance. A large amplitude of lift-off force increases the ramp force, the unloading time, the slider oscillation and contact-possibility. To minimize 'lift-off' force we optimizes the slider and suspension using the integrated optimization frame, which automatically integrates the analysis with the optimization and effectively implements the repetitive works between them. In particular, this study is carried out the optimal design considering the process of modes tracking through the entire optimization processes. As a result, we yield the equation which can easily find a lift-off force and structural optimization for suspension.

  • PDF

RC 골조의 내진 보강을 위한 예압 가새의 3-D 배치 (3-D Configuration Effects of Prestressing Cable Bracing Used for Retrofitting a RC Frame Subjected to Seismic Damage)

  • 이진호;오상균;히샴 엘간조리
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.183-191
    • /
    • 2003
  • 본 연구는 예압 가새로써 내진 보강된 RC 골조의 보강 효과를 3차원적으로 조사함이 그 목적이다. 이를 위해, 먼저 4층 규모의 RC 골조에 극한 하중을 가한 후 예압 가새를 이용하여 보강하되 보강 위치에 따라 3경우로 나누어 해석을 수행해보았다. 해석 방법으로써, 본 연구자가 앞서 행한 연구 결과에 의해 정적 붕괴 해석법이 비선형 동적 시간 이력 해석법의 대안책으로 훌륭히 쓰일 수 있음을 밝힌바 있기 때문에 정적 붕괴 해석만 적용하여 보강 전의 해석 및 보강 후의 영향에 대해서 평가하였다. 그 결과, 외주부에 설치한 가새가 커다란 비틀림 저항을 발휘했으며 예압 가새로 인해 골조에 균등한 강성 변화가 유도되어 급격한 파괴가 발생하지 않는 효과를 보였다.

고온을 받은 횡방향 철근 구속 콘크리트의 역학적 특성 연구 (Effect of High Temperature on Mechanical Properties of Confined Concrete with Lateral Reinforcement)

  • 최광호;이중원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.131-139
    • /
    • 2012
  • 콘크리트 기둥에 사용되는 횡방향 철근은 압축콘크리트 파괴 시 횡방향 벌어짐을 구속하여 폭렬을 줄일 수 있고 콘크리트의 연성을 증가시키는 데에 유효하며 강도손실 보상효과가 있다. 이를 규명하기 위하여, 띠철근의 간격과 나선철근을 변수로 한 실험체를 제작하여 가열실험을 수행하였다. 이 때 전기로 온도를 $300^{\circ}C$, $600^{\circ}C$$800^{\circ}C$로 설정하여 $13.33^{\circ}C$/분의 속도로 가열하고 2시간동안 그 온도를 유지시켰다. 냉각된 실험체에 대해 응력-변형률 곡선을 구하기 위한 압축실험을 수행하고, 이로부터 탄성계수, 잔존 내력 및 변형률 등의 잔존 역학적 특성을 분석하였다. 실험결과 횡방향 철근비가 높을수록 철근이 콘크리트를 구속하여 다축 응력 상태가 되기 때문에 고온을 받은 콘크리트의 잔존 최대응력이 커지고 더욱 큰 변형을 발휘할 수 있는 있는 것을 확인하였다. 이울러, 콘크리트의 잔존 탄성계수의 감소율은 횡방향 철근의 구속효과로 작아지는 것으로 분석되었다.

High Performance ESD/Surge Protection Capability of Bidirectional Flip Chip Transient Voltage Suppression Diodes

  • Pharkphoumy, Sakhone;Khurelbaatar, Zagarzusem;Janardhanam, Valliedu;Choi, Chel-Jong;Shim, Kyu-Hwan;Daoheung, Daoheung;Bouangeun, Bouangeun;Choi, Sang-Sik;Cho, Deok-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권4호
    • /
    • pp.196-200
    • /
    • 2016
  • We have developed new electrostatic discharge (ESD) protection devices with, bidirectional flip chip transient voltage suppression. The devices differ in their epitaxial (epi) layers, which were grown by reduced pressure chemical vapor deposition (RPCVD). Their ESD properties were characterized using current-voltage (I-V), capacitance-voltage (C-V) measurement, and ESD analysis, including IEC61000-4-2, surge, and transmission line pulse (TLP) methods. Two BD-FCTVS diodes consisting of either a thick (12 μm) or thin (6 μm), n-Si epi layer showed the same reverse voltage of 8 V, very small reverse current level, and symmetric I-V and C-V curves. The damage found near the corner of the metal pads indicates that the size and shape of the radius governs their failure modes. The BD-FCTVS device made with a thin n- epi layer showed better performance than that made with a thick one in terms of enhancement of the features of ESD robustness, reliability, and protection capability. Therefore, this works confirms that the optimization of device parameters in conjunction with the doping concentration and thickness of epi layers be used to achieve high performance ESD properties.

초음파 수침법을 이용한 터빈베어링 Babbitt금속 박리 검사 기술 (Implementation of Ultrasonic Immersion Technique for Babbitt Metal Debonding in Turbine Bearing)

  • 정계조;박상기;조용상;박병철;길두송
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.348-353
    • /
    • 2004
  • 이 연구는 터빈베어링의 신뢰성을 평가하기 위하여 초음파 C-Scan 방법을 적용한 기술이다. 수침법에 관한 연구는 실험실과 현장검사 적용에 광범위하게 사용되는 기술이다. 여기에서는 C-Scan 방법을 이용하여 베어링의 모재와 Babbitt 금속간 경계부의 상태를 평가하였다. 수침법 C-Scan 방법에 의한 초음파 영상은 베어링 경계부의 상태를 확인하는데 효과적인 방법으로 사용될 수 있었다. 초음파 영상의 분해능을 높이기 위하여 집속형 탐촉자를 사용하고, Babbitt 금속과 베어링 모재간의 접합경계면에서 발생하는 초음파 음압 반사율을 측정하여 결함의 검출과 면적을 추정할 수 있었다. 초음파 수침법은 베어링 접합부의 박리위치와 박리면적의 경계면을 결정하여 크기를 계산하는데 아주 유용하게 사용될 수 있는 기술이며, 이 연구에서 개발된 기술은 화력발전소에서 사용되고 있는 터빈베어링의 건전성을 확보하는데 적용되었다.