• 제목/요약/키워드: Damage Magnitude

검색결과 333건 처리시간 0.027초

고압전동기 모델 코일의 부분방전 분석 (Analysis of Partial Discharge in High Voltage Motor Model Coils)

  • 김희동;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF

Development of Pressure Control System of Contact Transducer for Measurement of Ultrasonic Nonlinear Parameter

  • Lee, In-Ho;Son, Dae-Soo;Choi, Ik-Hwang;Lee, Tae-Hun;Jhang, Kyung-Young
    • 비파괴검사학회지
    • /
    • 제27권6호
    • /
    • pp.576-581
    • /
    • 2007
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Especially, when we use contact PZT transducer, if the contacting pressure is not kept in constant during the measurement then there exists extraneous fluctuation in the measured nonlinearity caused by the unstable contact condition, In this paper, we developed a pneumatic control system to keep the contacting pressure of transducer in constant during the measurement and analyzed the effect of contacting pressure to the ultrasonic nonlinearity measurement As a result, we found that the pressure of transducer in our measurement system should be greater than 170 kPa to measure the ultrasonic nonlinear parameter in stable with no dependency on the contacting pressure.

터빈발전기의 축계 진동 해석: 열박음형과 용접형 로터의 진동 특성 비교 (Vibration Analysis of Rotating System in a Turbine and Generator Set: Comparison of Shrunk-fit Disc Rotor and Welded Drum Rotor)

  • 하현천;박철현;최성필;김계연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.599-604
    • /
    • 2000
  • Excessive vibration magnitude results in serious damage and economic losses in the turbine and generator system. Therefore, it is of importance to evaluate the accurate dynamic characteristics of the system in advance. In this paper, rotordynamic characteristics of both the shrunk-fit disc and welded drum rotors have been investigated to ensure an excellent running behavior of the system in which low-pressure(LP) turbines of a nuclear power plant were retrofitted to improve thermal efficiency and reliability. Analysis shows that the welded drum rotor has good torsional characteristics rather than the shrunk-fit disc rotor. In addition, verification testing of field test was performed to confirm the retrofit. Test results are good agreement with analysis ones.

  • PDF

Masonry building behaviors during the February 6-12, 2017 Ayvacik-Çanakkale Earthquakes

  • Ural, Ali
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.355-363
    • /
    • 2019
  • Masonry structures in the rural areas of Turkey often damaged due to moderate and big earthquakes. After every earthquake many scientists made field investigations on the earthquake performance of these structures and gave many useful information on construction techniques. However, the newly constructed masonry buildings are still not suitable for the suggested techniques, and they are still in danger against future earthquakes. Five moderate earthquakes of moment magnitude Mw 5.3, 5.3, 5.2, 5.0, and 5.3 struck the Ayvacik-Çanakkale District of Turkey between 6 and 12 February, 2017. More than a thousand of aftershocks were occurred and most of the masonry buildings in the villages nearby main shock epicenter were affected. The author went to the earthquake field and investigated the earthquake performances of masonry structures. This paper presents the recorded acceleration data, acceleration response spectra, and the seismological aspects of these earthquakes. Besides, case studies of damaged stone masonry buildings, and failure mechanisms are discussed with illustrated photos which were taken during the field investigations. It is concluded that the damaged masonry buildings were not designed and constructed properly in accordance with the Turkish building codes or similar specifications.

Neuro-fuzzy model of concrete exposed to various regimes combined with De-icing salts

  • Ghazy, Ahmed;Bassuoni, Mohamed. T.
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.649-659
    • /
    • 2018
  • Adaptive neuro-fuzzy inference systems (ANFIS) can be efficient in modelling non-linear, complex and ambiguous behavior of cement-based materials undergoing combined damage factors of different forms (physical and chemical). The current work investigates the use of ANFIS to model the behavior (time of failure (TF)) of a wide range of concrete mixtures made with different types of cement (ordinary and portland limestone cement (PLC)) without or with supplementary cementitious materials (SCMs: fly ash and nanosilica) under various exposure regimes with the most widely used chloride-based de-icing salts (individual and combined). The results show that predictions of the ANFIS model were rational and accurate, with marginal errors not exceeding 3%. In addition, sensitivity analyses of physical penetrability (magnitude of intruding chloride) of concrete, amount of aluminate and interground limestone in cement and content of portlandite in the binder showed that the predictive trends of the model had good agreement with experimental results. Thus, this model may be reliably used to project the deterioration of customized concrete mixtures exposed to such aggressive conditions.

방수층에 전달되는 진동 요구응답스펙트럼을 재해석 한 성능평가 시험장치 개발에 관한 연구 (A study on the development of a performance evaluation test apparatus for reinterpreting the vibration demand response spectrum for waterproof layers)

  • 김수연;이승진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.208-209
    • /
    • 2021
  • In 2017, 100 aftershocks with a magnitude of 2.0~3.0 and 615 minor earthquakes in Pohang in Korea caused the collapse and destruction of aggregate, tile, glass, and other structural components of multi-family houses constructed as finishing materials for buildings, causing damage to vehicles and casualties. Based on this factor, seismic design standards were established for non-structural elements of buildings that were applied only to past structures. Therefore, this study reinterpreted various vibration response spectra transmitted to waterproof layers as well as the definition and concept of the waterproof layer demand response spectrum derived by developing various vibration response test evaluation devices through a new testing apparatus.

  • PDF

농업부문 기후변화 대응정책의 IPA분석 (IPA Analysis of Agricultural Climate Adaptation Policies)

  • 이상호;홍재호
    • 농촌지도와개발
    • /
    • 제30권4호
    • /
    • pp.213-227
    • /
    • 2023
  • This paper aims to examine the farmers' perceptions of the importance and feasibility of climate change awareness and adaptive measures in agriculture, utilizing paired sample t-tests and Importance-Performance Analysis (IPA). Significant differences were found in farmers' views on the importance and urgency of climate change issues, with specific factors standing out. The IPA analysis identified key issues requiring sustained attention, including climate change magnitude, extreme weather events, livestock damage scale, pest fluctuations, and variability in flowering periods. Additionally, the study revealed significant disparities in farmers' perceptions of the importance and feasibility of adaptive measures, except for specific items related to heat indices.

9.12 경주지진 및 11.15 포항지진의 구조손상 포텐셜 비교연구 (Comparative Analysis of Structural Damage Potentials Observed in the 9.12 Gyeongju and 11.15 Pohang Earthquakes)

  • 이철호;김성용;박지훈;김동관;김태진;박경훈
    • 한국지진공학회논문집
    • /
    • 제22권3호
    • /
    • pp.175-184
    • /
    • 2018
  • In this paper, comparative analysis of the 9.12 Gyeongju and 11.15 Pohang earthquakes was conducted in order to provide probable explanations and reasons for the damage observed in the 11.15 Pohang earthquake from both earthquake and structural engineering perspectives. The damage potentials like Arias intensity, effective peak ground acceleration, etc observed in the 11.15 Pohang earthquake were generally weaker than those of the 9.12 Gyeongju earthquake. However, in contrast to the high-frequency dominant nature of the 9.12 Gyeongju earthquake records, the spectral power of PHA2 record observed in the soft soil site was highly concentrated around 2Hz. The base shear around 2 Hz frequency was as high as 40% building weight. This frequency band is very close to the fundamental frequency of the piloti-type buildings severely damaged in the northern part of Pohang. Unfortunately, in addition to inherent vertical irregularity, most of the damaged piloti-type buildings had plan irregularity as well and were non-seismic. All these contributed to the fatal damage. Inelastic dynamic analysis indicated that PHA2 record demands system ductility capacity of 3.5 for a structure with a fundamental period of 0.5 sec and yield base shear strength of 10% building weight. The system ductility level of 3.5 seems very difficult to be achievable in non-seismic brittle piloti-type buildings. The soil profile of the PHA2 site was inversely estimated based on deconvolution technique and trial-error procedure with utilizing available records measured at several rock sites during the 11.15 Pohang earthquake. The soil profile estimated was very typical of soil class D, implying significant soil amplification in the 11.15 Pohang earthquake. The 11.15 Pohang earthquake gave us the expensive lesson that near-collapse damage to irregular and brittle buildings is highly possible when soil is soft and epicenter is close, although the earthquake magnitude is just minor to moderate (M 5+).

영상을 활용한 시설물 안전점검 작업 효율성 향상 방안 연구 (A Study on Improving the Efficiency of Facility Safety Inspection Work Using Images)

  • 전경식;김진태;이병길
    • 한국측량학회지
    • /
    • 제39권3호
    • /
    • pp.179-186
    • /
    • 2021
  • 일반적으로 구조물에서의 손상을 조사하고 손상 크기를 측정하는 일상안전점검 활동은 지금까지 점검인력에 의한 육안점검에 크게 의존하고 있다. 이러한 인력에 의한 시설물의 상태 및 성능점검은 조사자의 주관적 판단에 의존하는 경우가 많기 때문에 측정결과의 일관성과 반복성이 저하될 수 있다. 특히 접근이 어려운 곳에 위치한 손상은 육안에 의한 경험에 주로 의존하고 있으며, 필요한 경우에 사다리를 이용하는 안전하지 못한 방법이 주로 사용되고 있다. 이에 본 연구에서는 안전점검 조사자 간 편차를 줄여 객관성을 확보하고, 작업자의 안전성을 강화할 수 있는 영상 활용 기법을 제안하고자 하였다. 본 연구에서는 촬영대상과의 거리와 촬영각도에 따른 영상의 변화를 보정하는 방법으로 평면사영변환을 적용하였다. 실험대상에 대한 변환된 영상에서 손상 크기를 분석한 결과 손상 크기 측정의 정확도는 목표 수준인 5.0mm와 0.005m2를 만족시킬 수 있는 것으로 확인되었다. 제안된 영상 보정 기법을 적용한 현장검증시험 결과, 구조물에 발생된 균열의 길이의 변동계수는 5.4~7.0%에서 0.072~0.12%로 감소하였고, 손상 면적의 변동계수는 10.9%에서 1.6%로 줄어들었고, 측정의 정확도가 향상되는 것을 확인하였다. 그러므로 안전점검 활동에서의 영상 활용 기법에 대한 본 연구를 통해 손상 크기 측정 정확도 향상 및 안전점검 보고서와 외관조사망도에 대한 신뢰도 향상을 기대할 수 있을 것으로 판단된다.

구조물 건전성 모니터링을 위한 Lamb파 모드 구별법 (A Method of Lamb-Wave Modes Decomposition for Structural Health Monitoring)

  • 전용주;박일욱;이우식
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.887-895
    • /
    • 2012
  • Lamb waves have received a great attention in the structural health monitoring (SHM) societies because they can propagate over relatively large distances in wave guides such as thin plates and shells. The time-of-flights of Lamb waves can be used to detect damages in a wave guide. However, due to the inherent dispersive and multi-mode characteristics of Lamb waves, one must decompose the Lamb wave modes into the symmetric and anti-symmetric modes for SHM applications. Thus, this paper proposes a decomposition method for the two-mode Lamb waves based on two rules: the group velocity ratio rule and the mode amplitude ratio rule. The group velocity ratio rule means that the ratio of the group velocities of fundamental symmetric and anti-symmetric modes is constant, while the mode amplitude ratio rule means that the magnitude of the fundamental symmetric modes of all measured response signals should be always larger than those of the anti-symmetric mode once the input signal is applied so that the magnitude of fundamental symmetric mode of excited Lamb-wave is larger than that of anti-symmetric mode, and vice versa. The proposed method is verified through the experiments ducted for an aluminum plate specimen.