• 제목/요약/키워드: Dam process

검색결과 294건 처리시간 0.03초

A Study on Properties of SSBR/NdBR Rubber Composites Reinforced by Silica

  • Lee, Dam-Hee;Li, Xiang Xu;Cho, Ur-Ryong
    • Elastomers and Composites
    • /
    • 제53권4호
    • /
    • pp.202-206
    • /
    • 2018
  • Five solution styrene butadiene rubber/neodymium butadiene rubber (SSBR/NdBR) composites were manufactured using different ratios of SSBR and NdBR. In this study, the composites were reinforced with NdBR and silica to confirm the physical properties of SSBR used for treads of automobile tires and the dispersibility with silica. The morphologies of the rubber composites were observed using field-emission scanning electron microscopy (FE-SEM). The crosslinking behaviors of the composites were tested using a rubber process analyzer (RPA), and the abrasion resistances were tested using a National Bureau of Standards (NBS) abrasion tester. The hardness values, tensile strengths, and cold resistances of the composites were also tested according to ASTM standards. Increased NdBR content yielded composites with excellent crosslinking properties, abrasion resistances, hardnesses, tensile strengths, and cold resistances. The crosslinking point increased due to the double bond in NdBR, thereby increasing the degree of crosslinking in the composites. The NdBR-reinforced composites exhibited excellent abrasion resistances, which is explained as follows. In SSBR, a breakage is permanent because a resonance structure between styrene and SSBR forms when the molecular backbone is broken during the abrasion process. However, NdBR forms an additional crosslink due to the breakdown of the molecular backbone and high reactivity of the radicals produced. In addition, the low glass transition temperature (Tg) of NdBR provided the rubber composites with excellent cold resistances.

Parametric Study of a Fixed-blade Runner in an Ultra-low-head Gate Turbine

  • Mohamed Murshid Shamsuddeen;Duc Anh Nguyen;Jin-Hyuk Kim
    • 신재생에너지
    • /
    • 제20권1호
    • /
    • pp.116-125
    • /
    • 2024
  • Ultra-low-head is an unexplored classification among the sites in which hydroelectric power can be produced. This is typically owing to the low power output and the economic value of the turbines available in this segment. A turbine capable of operating in an ultra-low-head condition without the need of a dam to produce electricity is developed in this study. A gate structure installed at a shallow water channel acting as a weir generates artificial head for the turbine mounted on the gate to produce power. The turbine and generator are designed to be compact and submersible for an efficient and silent operation. The gate angle is adjustable to operate the turbine at varying flow rates. The turbine is designed and tested using computational fluid dynamics tools prior to manufacturing and experimental studies. A parametric study of the runner blade parameters is conducted to obtain the most efficient blade design with minimal hydraulic losses. These parameters include the runner stagger and runner leading edge flow angles. The selected runner design showed improved hydraulic characteristics of the turbine to operate in an ultra-low-head site with minimal losses.

개페식 파지공구 메카니즘의 기구학적 최적 설계 (Kinematic Optical Design of an Open-Close Type Gripper Mechanism)

  • 김희국;박주영;윤성식
    • 대한기계학회논문집A
    • /
    • 제20권6호
    • /
    • pp.1762-1772
    • /
    • 1996
  • The main objective of this study is to develop a gripper mechanixm that can be employed for assembly and removal tasks of a nozzle-dam of steam genetator in the process of the nuclear reactor maintenances. Brief description of the open-close thpe gripper mechanism, its position analysis, and its kinematic analysis are given. The optimal design of the gripper mechanism with and without slipping on its two gipping surfaces is considered. As an optimal design index, the ratio of the actuator force of prismatic cylinder to gripping load is proposed. Then, based on this index the oiptimal design is carried out to identify values of optimal design parameters for the gripper dechanism.

방음대책 수립 후 수차발전기 소음의 저감효과 평가에 관한 연구 (A Study on the Evaluation for Reduction Effect of Hydraulic Turbine Dynamo Noise after Establishment of Soundproof Measure)

  • 윤재현;주덕훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.133-137
    • /
    • 2007
  • As the waterpower generation plant, the subject of this Study, is a facility that produces plenty of electricity corresponds to $196{\sim}240GWh$ annually, and in its generation process it creates a loud noise when the turbine related to the hydraulic turbine dynamo revolves, and since such loud noise must be transmitted to the dynamo room and amplified, it is effecting a lot of influences to the adjacent office and space. In such viewpoint, this Research, based on the soundproof measure presented at the preceding research, has attempted to evaluate about the effect of noise-reduction countermeasure against the hydraulic turbine dynamo using Auralizational Technique through Psycho-Acoustics Experiment. It deems that such result could be applied hereafter as the useful material when setting up a soundproof countermeasure for the hydraulic turbine dynamo room in dam.

  • PDF

Comparative Studies on the Acute Toxicities of Whole Solids and Solids Aqueous Extracts Based on the Inhibition of Bacterial Bioluminescence Production

  • Kong, In-Chul
    • Environmental Engineering Research
    • /
    • 제16권1호
    • /
    • pp.41-45
    • /
    • 2011
  • The aim of this investigation was to demonstrate a rapid bioluminescence bioassay for comparison of the toxicity of whole solids and the aqueous extracts of various environmental solid samples. With regard to the toxicities, those for the soil extracts were mostly found to be lower than those of whole soils, which may have been caused by un-extracted pollutants or dilution during the extraction process. Solid samples from dam-reservoir sediments and municipal refuses were also tested. The toxicities of the solid extracts (0-34%; refuses and sediments) were much lower than those of the whole solids (13-91%). The bioluminescence inhibition test indicated that the harmful effects of the contaminated solids samples were greater than those of the solid extracts.

하천유량관리를 위한 GIS 하도단면 구축 (Establishment of GIS River Section for Water Flow Management)

  • 최철관;김상호;배덕효;한건연
    • Spatial Information Research
    • /
    • 제8권1호
    • /
    • pp.131-140
    • /
    • 2000
  • 하천의 흐름해석 분야에서는 모형이 요구하는 입·출력 자료의 구성이 복잡할 뿐만 아니라 흐름의 공간적 분포특성 도시가 매우 중요하지만 지금까지 체계적인 자료관리가 이루어지지 않은 실정이다. 본 연구에서는 등고, 하천, 표고, 경계 및 하도단면 등으로 구성된 국가지리정보시스템과 연계된 데이터베이스를 구축하는 방법과 등간격 하도단면 자료를 구축하는 방법을 제안하였다. 연구대상지역은 팔당댐 하류에서 인도교 지점에 이르는 한강구간을 선택하였다. 구축된 데이터베이스는 연구대상지역의 과학적인 하천유량 관리에 유용하게 이용될 것이다.

  • PDF

Elimination of the Red-Eye Area using Skin Color Information

  • Kim, Kwang-Baek;Song, Doo-Heon
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.131-134
    • /
    • 2009
  • The red-eye effect in photography occurs when using a photographic flash very close to the camera lens, in ambient low light due to in experience. Once occurred, the photographer needs to remove it with image tool that requires time consuming, skillful process. In this paper, we propose a new method to extract and remove such red-eye area automatically. Our method starts with transforming ROB space to YCbCr and HSI space and it extracts the face area by using skin color information. The target red-eye area is then extracted by applying 8-direction contour tracking algorithm and removed. The experiment shows our method's effectiveness.

탱크 모델에 의한 홍수(洪水) 유출량(流出量) 해석(解析)에 관(關)한 연구(硏究) (A study on the flood runoff analysis with TANK MODEL)

  • 홍창선;최한규
    • 산업기술연구
    • /
    • 제3권
    • /
    • pp.95-101
    • /
    • 1983
  • This study aims at the determination of the coefficienties of runoff and infiltration affecting runoff. The rating curve is more available than the peak flood runoff to determine flood control plan of flood control reservoir and the volume of hydroelectric power plant, or to make multipurpose dam. In hydrologic analysis and design, it is necessary to develop relations between precipitation and runoff, possible using some of the factors affecting runoff as parameters. In order to calculate the runoff discharge, the runoff process constituting elements are divided to the surface runoff, the subsurface runoff and the groundwater runoff. By comparing the computed hydrograph with the measured hydrograph, determinned the watershed TANK Model constant Varying the tank model constant for approximating the computed hydrograph to the measured hydrograph.

  • PDF

Fasad (Venesection): An important regimental therapy in Unani System of Medicine

  • Khan, Javed ahmad;Nikhat, Shagufta;Ahmad, Naseem;Zohaib, Sharique;Parray, Shabir ahmad
    • 셀메드
    • /
    • 제7권4호
    • /
    • pp.19.1-19.5
    • /
    • 2017
  • Fasad i.e. venesection is an old classical method of treatment in the Unani system of medicine. Fasad is Arabic word which means "to open". In the process, complete evacuation which drains out blood and dominating humours mixed with blood from veins. Fasad is carried out when the kamiyat (quantity) of the blood is excess in the body and patient is either exposed to the risk of developing a disease or has actually developed one. In classical literature of Unani system of medicine, physicians wrote a lot about this procedure. The details of venesection is mentioned in the given paper on the basis of classical literature including history, indications, types, amount of blood to be venesected, time, person, procedure, complications and special focus has been made on the number of vessels to be venesected and their benefits with respected to disease and condition.

변형 연속회분식 반응기를 이용한 오수의 고도처리 (Advanced Sewage Treatment by the Modified SBR(Sequencing Batch Reactor) Process)

  • 김병군;서인석;홍성택;정위득
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.46-51
    • /
    • 2002
  • This study was performed to treat a sewage at the upper stream of dam using modified sequencing batch reactor, During the operating period, average $COD_{cr}$, removal efficiency was about 85% but average T-N and ${PO_4}^{3-}-P$ removal efficiencies were 43% and 30% respectively. Because the organic matter was very low compared with nitrogen and phosphorous in influent($BOD_{5}/{NH_4}^{+}-N{\;}={\;}2,{\;}BOD_{5}/{PO_4}^{3-}-P{\;}={\;}15.6$), nitrogen and phosphorus removal efficiency was relatively low. Average nitrogen removal efficiency was 50 % at $10^{\circ}C$ or above and it was 36 % at $10^{\circ}C$ or below. As reactor was located in outdoor without any thermostat, temperature decreased at least $2.4^{\circ}C$ in the winter season. Therefore, if we would apply this modified sequencing batch reactor to sewage which concentration of organic matter was very low compared with nitrogen and phosphorous, we have to addition of external carbon and installation of any thermostat.