• Title/Summary/Keyword: Dam failure

Search Result 155, Processing Time 0.022 seconds

A Study on the Estimation of Stability of Fill Dam by Long-term Electrical Resistivity Monitoring (장주기 전기비저항 모니터링 기법을 이용한 필댐의 안정성 평가)

  • Kim, Gi-Ho;Lim, Heui-Dae;Ahn, Hee-Yoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.53-64
    • /
    • 2013
  • Resistivity monitoring is based on the fact that a change in the porosity leads to the changes in water content and fine particles, which alter the electrical resistivity. At every embankment dam, internal erosion always occurs as time passes. The internal erosion generally develops into piping over a long time by backward erosion and concentrated leak, and finally leads to dam failure. Resistivity is known to be very sensitive to the changes in porosity in embankment dams. Thus resistivity monitoring is a reasonable method to find out the leakage zone. However, resistivity is strongly influenced by seasonal variation of temperature, TDS of reservoir water and water level. In this paper. we first installed electrodes permanently at the center of the crest. The electrical resistivity monitoring data was acquired every 6 hours from Apr. 3, 2011 to July. 31, 2012. To analyze the characteristics of monitoring data, each resistivity data was calculated from up to 2,950 data sets. The result indicated a seasonal resistivity variation due to related temperature. Finally, a quantitative method to estimate porosities of the embankment dam from the resistivity monitoring data was analyzed. The applicability and reliability were verified and the importance of electrical resistivity monitoring for obtaining reliable result was emphasized.

Effect of Vapor-dam Treatment and End-coating Treatment on the air Circulating oven Drying Characteristics of Green Stocks for Korean Traditional Double-headed Drum (수증기댐처리 및 엔드코팅처리가 장고용 초갈이재의 송풍오븐건조 특성에 미치는 영향)

  • Lee, Nam-Ho;Jung, Hee-Suk;Hayashi, Kazuo;Li, Cheng-Yuan;Zhao, Xue-Feng;Hwang, Ui-Do
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.17-26
    • /
    • 2007
  • This study was conducted to investigate the effects of End-coating (CO) treatment and Vapor-dam (V) treatment on the air circulating oven drying characteristics of green stock (Paulownia tomentosa) for drum. The reduction of the weight of specimens was greatly displayed in order of control (C-NC) treatment, End-coating (C-CO) treatment, Vapor-dam (V-NC) treatment and Vapor-dam/End-coating (V-CO) treatment after the beginning of drying. The V-CO treated specimen showed smoother temperature gradient compared with the V-NC treated specimen throughout whole drying stage and there was little temperature gradient between the inner and outer part of the cylindrical stock. The C-CO treated specimen showed higher value of vapor pressure in both the inner and outer part of the cylindrical stock until the middle stage of drying, while after the middle stage of drying only the inner part of the cylindrical stock presented higher value compared with the C-NC treated specimen. The distribution of the absolute vapor pressure of the V-CO treated specimen was similar to that of the V-NC treated specimen during the initial stage of drying. However, the former showed a large distribution in order of the hollow, the outer part, the inner part of the cylindrical stock after the initial stage of drying, which was entirely different model of distribution from that of the V-NC treated specimen. Surface checks and ring failures were not observed for all of the specimens, while end checks were severely occurred for the C-NC treated specimen and the V-NC treated specimen.

Real-time Reservoir Dam Status Evaluation System Using Wireless Sensor Network System (무선 센서 네트워크 시스템을 이용한 실시간 저수지 댐의 상태평가 시스템)

  • Yoo, Chanho;Kim, Seungwook;Hwang, Jungsoon;Na, Gihyuk;You, Kwangho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.41-46
    • /
    • 2018
  • The wireless sensor network system has the advantage of confirming the behavior of the entire facility by improving the disadvantages of conventional monitoring system. As a result, it is widely proposed as safety diagnosis and measurement of structures, water management systems, and management systems for dam structures. However, there is a lack of research that can evaluate the condition of facilities such as safety at the same time as monitoring. In this study, it is proposed a wireless sensor network system which can evaluate the behavior characteristics of facilities and evaluate the safety status for improving the technical disadvantages on conventional monitoring system. The geotechnical risk factors for the reservoir dam facility were evaluated and the limit values for the risk factors causing the failure of the facility were set. In other words, the system was set up so that the risk factors can be measured and the limit status can be evaluated immediately for each factor. In this study, numerical analysis is carried out for seepage and slope stability analysis using the typical cross section for reservoir dams. The stress-porewater coupling finite difference numerical analysis is performed for establishing the limit displacement for reservoir dam structures. It is developed a system that can estimate the time to reach the critical value by regression analysis using the measured datas.

Quantitative Evaluation of Leak Index from Electrical Resistivity and Induced Polarization Surveys in Embankment Dams (전기비저항 및 유도분극 탐사에 의한 저수지 누수지수 산출)

  • Cho, In Ky;Kim, Yeon Jung;Song, Sung Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.3
    • /
    • pp.120-128
    • /
    • 2022
  • There are 17,000 reservoir dams in Korea, of which more than 85% were built over 50 years ago. Old embankment dams are weakened by internal erosion and suffusion phenomena due to preferential leakage paths and this ongoing weakening can cause their failure. Therefore, early warning associated with leakage in an embankment dam is crucial to prevent its failure. An electrical resistivity survey is a non-destructive, real-time and in-situ technique for detecting the development of leakage zones and general conditions of embankment dams. Because of its advantages, the electrical resistivity survey is widely used for reservoir safety inspections. However, the electrical resistivity survey is still not officially included in the precise safety inspection of reservoir dams because it cannot present a quantitative index of dam safety. In this study, we propose a method for calculating the leak index according to the water content evaluated from the electrical resistivity survey and/or induced polarization survey. Particularly, by proposing a quantitative leak index calculation method from monitoring surveys and independent surveys, we provide a theoretical basis for including electrical resistivity and induced polarization surveys as components of the precise safety inspection of reservoirs dams.

Calculation of overtopping discharge with time-dependent aspects of an embankment failure (시간에 따른 제방붕괴 양상을 고려한 월류량 산정)

  • Kim, Hyung-Jun;Kim, Jong-Ho;Jang, Won-Jae;Cho, Yong-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.3
    • /
    • pp.69-78
    • /
    • 2007
  • In this study, a time-dependent aspect of an embankment failure is considered to simulate a flood inundation map and calculate overtopping discharge induced by an embankment failure. A numerical model has been developed by solving the two dimensional nonlinear shallow water equations with a finite volume method on unstructured grids. To analyze a Riemann problem, the HLLC approximate Riemann solver and the Weighted Averaged Flux method are employed by using a TVD limiter and the source term treatment is also employed by using the operator splitting method. Firstly, the numerical model is applied to a dam break problem and a sloping seawall. Obtained numerical results show good agreements with experimental data. Secondly, the model is applied to a flow induced by an embankment failure by assuming that the width and elevation of embankment are varied with time-dependent functions. As a result of the comparison with each numerical overtopping discharge, established flood inundation discharges in the previous studies are overestimated than the result of the present numerical model.

A study on the Average Factor of Safety in Slope Stability Being Applied to Wedge theory (Wedge 이론을 적용한 사면안정해석의 평균 안전율에 관한 연구)

  • 김경진
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 1986
  • The analysis of Geotechnical stability problems by the limit equilibrium method involve assuming the shape of the failure and then investigating many surfaces of the shape to identify the one on which failure seems most likely to occur. These arbitrary assumptions most frequently concern to the locations or directions of side force on slice and the overall factor of safety is considered identical to the local factor of safety. In this paper, let the factor of safety of a slope at wedge block stage differently, when an upper part of the potential sliding mass has a simple active stress field and the lower part of the passive stress field and overall factor of safety is obtained by the average of local factor and computer program based on the modified wedge Method is proposed for this thesis. The new algorithm based on tile modified new method is made for estimating the safety factor of Earth Dam. Compared with conventional method for many cases tile average values of the factor of safety determined by the modified new method are very nearly the same. For all of the cases studied the difference was found 0.03. Finally this new method is thought to be very useful in slope stability analysis.

  • PDF

Response of lap splice of reinforcing bars confined by FRP wrapping: modeling approach

  • Thai, Dam Xuan;Pimanmas, Amorn
    • Structural Engineering and Mechanics
    • /
    • v.37 no.1
    • /
    • pp.95-110
    • /
    • 2011
  • This paper presents a tri-uniform bond stress model for predicting the lap splice strength of reinforcing bar at the critical bond splitting failure. The proposed bond distribution model consists of three zones, namely, splitting zone, post-splitting zone and yielding zone. In each zone, the bond stress is assumed to be constant. The models for bond strength in each zone are adopted from previous studies. Combining the equilibrium, strain-slip relation and the bond strength model in each zone, the steel stress-slip model can be derived, which can be used in the nonlinear frame analysis of the column. The proposed model is applied to derive explicit equations for predicting the strength of the lap splice strengthened by fiber reinforced polymer (FRP) in both elastic and post-yield ranges. For design purpose, a procedure to calculate the required FRP thickness and the number of FRP sheets is also presented. A parametric investigation was conducted to study the relation between lap splice strength and lap splice length, number and thickness of FRP sheets and the ratio of concrete cover to bar diameter. The study shows that the lap splice strength can be enhanced by increasing one of these parameters: lap splice length, number or thickness of FRP sheets and concrete cover to bar diameter ratio. Verification of the model has been conducted using experimental data available in literature.

Quality Grading of Concrete Soil Erosion Control Dam in the Aspect of Unconfined Concrete Strength by Surface-Wave Technique (표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가)

  • Lee, Chang-Woo;Joh, Sung-Ho;Park, Ki-Hyung;Kim, Min-Sik;Yoon, Ho-Joong;Raja Ahmad, Raja Hassanul
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.412-425
    • /
    • 2012
  • Concrete Soil Erosion Control Dam, which blocks flow of debris flow in torrential stream, are reported to lose expected functions due to structural failure and collapses, caused by poor construction, material deterioration and external impacts. In this paper, an integrity assessment technique for debris barriers was proposed, which allows preliminary detection of problems inherent in debris barriers. The proposed integrity assessment technique is a non-destructive method based on SASW method, one of surface-wave tests. In this paper, a practical procedure and analysis guidelines in applying the SASW technique to debris barrier was proposed and its validity was verified using five decrepit debris barriers older than 20-year old. As a result, the SASW method was validated for the reliable grade evaluation method for concrete soil erosion control dam, and the resulting grades turned out to agree with the results determined by Sabang Associations.

Analysis of the adhesive damage between composite and metallic adherends: Application to the repair of aircraft structures

  • Ibrahim, Nour Chafak;Bouanani, Morad Fari;Bouiadjra, Bel Abbes Bachir;Serier, Boualem
    • Advances in materials Research
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • In bonded composite repair of aircraft structures, the damage of the adhesive can thus reduce significantly the efficiency and the durability of the bonded composite repair. The adhesive damage models using critical zone have proven their effectiveness due to simplicity and ap-plicability of the damage criteria in these models. The scope of this study is to analyze the effects of the patch thickness and the adhesive thickness on the damage damage in bonded composite repair of aircraft structures by using modified damage zone theory. The obtained results show that, when the thickness of adhesive increases the damage zone increases and the adhesive loses its rigidity, inversely when the patch is reduced the adhesive damage be-comes more significant.

Experimental Study on Corrosion Rate in Concrete

  • Jang, BongSeok;Oh, ByungHwan
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.34-38
    • /
    • 2004
  • The corrosion of reinforcement is a very important factor on the serviceability and safety of reinforced concrete structures. The corrosion rate influences directly the cover failure time of reinforced concrete structures because the corrosion rate is used to estimate the amount of corrosion and thus expansive pressure due to corrosion. In this study, several series of experiments are performed considering the chloride concentration in artificial pore solution. The potentials are measured according to the applied current density and then corrosion current densities are obtained from the Tafel plot for various chloride concentrations. The measured corrosion rates show good correlation with those of other researchers.