• 제목/요약/키워드: Daily maximum ground surface temperature

검색결과 11건 처리시간 0.028초

도시 토지피복별 불투수면적률과 녹지면적률에 따른 지표면 일최고온도 변화량 산정방법 (Development of calculating daily maximum ground surface temperature depending on fluctuations of impermeable and green area ratio by urban land cover types)

  • 김영란;황성환
    • 상하수도학회지
    • /
    • 제35권2호
    • /
    • pp.163-174
    • /
    • 2021
  • Heatwaves are one of the most common phenomena originating from changes in the urban thermal environment. They are caused mainly by the evapotranspiration decrease of surface impermeable areas from increases in temperature and reflected heat, leading to a dry urban environment that can deteriorate aspects of everyday life. This study aimed to calculate daily maximum ground surface temperature affecting heatwaves, to quantify the effects of urban thermal environment control through water cycle restoration while validating its feasibility. The maximum surface temperature regression equation according to the impermeable area ratios of urban land cover types was derived. The estimated values from daily maximum ground surface temperature regression equation were compared with actual measured values to validate the calculation method's feasibility. The land cover classification and derivation of specific parameters were conducted by classifying land cover into buildings, roads, rivers, and lands. Detailed parameters were classified by the river area ratio, land impermeable area ratio, and green area ratio of each land-cover type, with the exception of the rivers, to derive the maximum surface temperature regression equation of each land cover type. The regression equation feasibility assessment showed that the estimated maximum surface temperature values were within the level of significance. The maximum surface temperature decreased by 0.0450℃ when the green area ratio increased by 1% and increased by 0.0321℃ when the impermeable area ratio increased by 1%. It was determined that the surface reduction effect through increases in the green area ratio was 29% higher than the increasing effect of surface temperature due to the impermeable land ratio.

Observational Study for the Thermal Environment Evaluation of Summertime over the Asphalt Pavement - Case Study in Daegu 2014 -

  • Kim, Hae-Dong;Kim, Sung-Rak;Kim, Baek-Jo
    • 한국환경과학회지
    • /
    • 제24권10호
    • /
    • pp.1265-1272
    • /
    • 2015
  • To investigate the thermal environment over the summertime asphalt pavements, an automatic weather observation system was installed at a parking lot paved with asphalt to observe various meteorological parameters and surface temperature from July 1 to September 30, 2014. Since the number of rainy days in summer of 2014 particularly after the mid July is more than that of average data, a ratio of daily peak surface temperature above $45^{\circ}C$ was 28% which was lower than the average. The observational data about hourly average surface temperature and various heat balance factors at days where daily peak surface temperature is above $45^{\circ}C$ are as follows: An hour that had the daily maximum temperature was around 15 pm and the value was $49^{\circ}C$ approximately. Net shortwave radiation was the highest at 12pm as $800W/m^2$ and much radiation of $500W/m^2$ was absorbed at the ground between 11am and 17pm. Sensible heat that was delivered from the ground to the atmosphere was evaluated as $200W/m^2$ between 10am and 19pm. underground transfer heat up to $100W/m^2$ was measured as negative from 19pm to the next day 8am, which indicated the lower atmosphere was heated at night.

지상 고밀도 관측 시스템을 이용한 대구의 여름철 고온현상 조사 (Investigation of Urban High Temperature Phenomenon in Summer using the High Density Ground Monitoring System in Daegu Metropolitan Area)

  • 김상헌;조창범;김해동
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1619-1626
    • /
    • 2014
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network in Daegu metropolitan city, the representative basin-type city in Korea, in summer, 2013. We used a total of 28 air temperature observation points data(16 thermometers and 12 AWSs). From the distribution of monthly average air temperature, air temperature at the center of Daegu was higher than the suburbs. Also, the days of daily minimum air temperature more than or equal to $25^{\circ}C$ and daily maximum air temperature more than or equal to $35^{\circ}C$ at the schools near the center of Daegu was more than those at other schools. This tendency appeared more clearly on the days of daily minimum air temperature more than or equal to $25^{\circ}C$. Also, the air temperature near the center of the city was higher than that of the suburbs in the early morning. Thus it was indicated that the air temperature was hard to decrease as the bottom of the basin. From these results, the influence of urbanization to the formation of the daily minimum temperature in Daegu was indicated.

지하수 관개에 의한 수도의 멸준양상과 그 방지책에 관한 연구 (Studies on the Rice Yield Decreased by Ground Water Irrigation and Its Preventive Methods)

  • 한욱동
    • 한국농공학회지
    • /
    • 제16권1호
    • /
    • pp.3225-3262
    • /
    • 1974
  • The purposes of this thesis are to clarify experimentally the variation of ground water temperature in tube wells during the irrigation period of paddy rice, and the effect of ground water irrigation on the growth, grain yield and yield components of the rice plant, and, furthermore, when and why the plant is most liable to be damaged by ground water, and also to find out the effective ground water irrigation methods. The results obtained in this experiment are as follows; 1. The temperature of ground water in tube wells varies according to the location, year, and the depth of the well. The average temperatures of ground water in a tubewells, 6.3m, 8.0m deep are $14.5^{\circ}C$ and $13.1^{\circ}C$, respercively, during the irrigation period of paddy rice (From the middle of June to the end of September). In the former the temperature rises continuously from $12.3^{\circ}C$ to 16.4$^{\circ}C$ and in the latter from $12.4^{\circ}C$ to $13.8^{\circ}C$ during the same period. These temperatures are approximately the same value as the estimated temperatures. The temperature difference between the ground water and the surface water is approximately $11^{\circ}C$. 2. The results obtained from the analysis of the water quality of the "Seoho" reservoir and that of water from the tube well show that the pH values of the ground water and the surface water are 6.35 and 6.00, respectively, and inorganic components such as N, PO4, Na, Cl, SiO2 and Ca are contained more in the ground water than in the surface water while K, SO4, Fe and Mg are contained less in the ground water. 3. The response of growth, yield and yield components of paddy rice to ground water irrigation are as follows; (l) Using ground water irrigation during the watered rice nursery period(seeding date: 30 April, 1970), the chracteristics of a young rice plant, such as plant height, number of leaves, and number of tillers are inferior to those of young rice plants irrigated with surface water during the same period. (2) In cases where ground water and surface water are supplied separately by the gravity flow method, it is found that ground water irrigation to the rice plant delays the stage at which there is a maximum increase in the number of tillers by 6 days. (3) At the tillering stage of rice plant just after transplanting, the effect of ground water irrigation on the increase in the number of tillers is better, compared with the method of supplying surface water throughout the whole irrigation period. Conversely, the number of tillers is decreased by ground water irrigation at the reproductive stage. Plant height is extremely restrained by ground water irrigation. (4) Heading date is clearly delayed by the ground water irrigation when it is practised during the growth stages or at the reproductive stage only. (5) The heading date of rice plants is slightly delayed by irrigation with the gravity flow method as compared with the standing water method. (6) The response of yield and of yield components of rice to ground water irrigation are as follows: \circled1 When ground water irrigation is practised during the growth stages and the reproductive stage, the culm length of the rice plant is reduced by 11 percent and 8 percent, respectively, when compared with the surface water irrigation used throughout all the growth stages. \circled2 Panicle length is found to be the longest on the test plot in which ground water irrigation is practised at the tillering stage. A similar tendency as that seen in the culm length is observed on other test plots. \circled3 The number of panicles is found to be the least on the plot in which ground water irrigation is practised by the gravity flow method throughout all the growth stages of the rice plant. No significant difference is found between the other plots. \circled4 The number of spikelets per panicle at the various stages of rice growth at which_ surface or ground water is supplied by gravity flow method are as follows; surface water at all growth stages‥‥‥‥‥ 98.5. Ground water at all growth stages‥‥‥‥‥‥62.2 Ground water at the tillering stage‥‥‥‥‥ 82.6. Ground water at the reproductive stage ‥‥‥‥‥ 74.1. \circled5 Ripening percentage is about 70 percent on the test plot in which ground water irrigation is practised during all the growth stages and at the tillering stage only. However, when ground water irrigation is practised, at the reproductive stage, the ripening percentage is reduced to 50 percent. This means that 20 percent reduction in the ripening percentage by using ground water irrigation at the reproductive stage. \circled6 The weight of 1,000 kernels is found to show a similar tendency as in the case of ripening percentage i. e. the ground water irrigation during all the growth stages and at the reproductive stage results in a decreased weight of the 1,000 kernels. \circled7 The yield of brown rice from the various treatments are as follows; Gravity flow; Surface water at all growth stages‥‥‥‥‥‥514kg/10a. Ground water at all growth stages‥‥‥‥‥‥428kg/10a. Ground water at the reproductive stage‥‥‥‥‥‥430kg/10a. Standing water; Surface water at all growh stages‥‥‥‥‥‥556kg/10a. Ground water at all growth stages‥‥‥‥‥‥441kg/10a. Ground water at the reproductive stage‥‥‥‥‥‥450kg/10a. The above figures show that ground water irrigation by the gravity flow and by the standing water method during all the growth stages resulted in an 18 percent and a 21 percent decrease in the yield of brown rice, respectively, when compared with surface water irrigation. Also ground water irrigation by gravity flow and by standing water resulted in respective decreases in yield of 16 percent and 19 percent, compared with the surface irrigation method. 4. Results obtained from the experiments on the improvement of ground water irrigation efficiency to paddy rice are as follows; (1) When the standing water irrigation with surface water is practised, the daily average water temperature in a paddy field is 25.2$^{\circ}C$, but, when the gravity flow method is practised with the same irrigation water, the daily average water temperature is 24.5$^{\circ}C$. This means that the former is 0.7$^{\circ}C$ higher than the latter. On the other hand, when ground water is used, the daily water temperatures in a paddy field are respectively 21.$0^{\circ}C$ and 19.3$^{\circ}C$ by practising standing water and the gravity flow method. It can be seen that the former is approximately 1.$0^{\circ}C$ higher than the latter. (2) When the non-water-logged cultivation is practised, the yield of brown rice is 516.3kg/10a, while the yield of brown rice from ground water irrigation plot throughout the whole irrigation period and surface water irrigation plot are 446.3kg/10a and 556.4kg/10a, respectivelely. This means that there is no significant difference in yields between surface water irrigation practice and non-water-logged cultivation, and also means that non-water-logged cultivation results in a 12.6 percent increase in yield compared with the yield from the ground water irrigation plot. (3) The black and white coloring on the inside surface of the water warming ponds has no substantial effect on the temperature of the water. The average daily water temperatures of the various water warming ponds, having different depths, are expressed as Y=aX+b, while the daily average water temperatures at various depths in a water warming pond are expressed as Y=a(b)x (where Y: the daily average water temperature, a,b: constants depending on the type of water warming pond, X; water depth). As the depth of water warning pond is increased, the diurnal difference of the highest and the lowest water temperature is decreased, and also, the time at which the highest water temperature occurs, is delayed. (4) The degree of warming by using a polyethylene tube, 100m in length and 10cm in diameter, is 4~9$^{\circ}C$. Heat exchange rate of a polyethylene tube is 1.5 times higher than that or a water warming channel. The following equation expresses the water warming mechanism of a polyethylene tube where distance from the tube inlet, time in day and several climatic factors are given: {{{{ theta omega (dwt)= { a}_{0 } (1-e- { x} over { PHI v })+ { 2} atop { SUM from { { n}=1} { { a}_{n } } over { SQRT { 1+ {( n omega PHI) }^{2 } } } } LEFT { sin(n omega t+ { b}_{n }+ { tan}^{-1 }n omega PHI )-e- { x} over { PHI v }sin(n omega LEFT ( t- { x} over {v } RIGHT ) + { b}_{n }+ { tan}^{-1 }n omega PHI ) RIGHT } +e- { x} over { PHI v } theta i}}}}{{{{ { theta }_{$\infty$ }(t)= { { alpha theta }_{a }+ { theta }_{ w'} +(S- { B}_{s } ) { U}_{w } } over { beta } , PHI = { { cpDU}_{ omega } } over {4 beta } }}}} where $\theta$$\omega$; discharged water temperature($^{\circ}C$) $\theta$a; air temperature ($^{\circ}C$) $\theta$$\omega$';ponded water temperature($^{\circ}C$) s ; net solar radiation(ly/min) t ; time(tadian) x; tube length(cm) D; diameter(cm) ao,an,bn;constants determined from $\theta$$\omega$(t) varitation. cp; heat capacity of water(cal/$^{\circ}C$ ㎥) U,Ua; overall heat transfer coefficient(cal/$^{\circ}C$ $\textrm{cm}^2$ min-1) $\omega$;1 velocity of water in a polyethylene tube(cm/min) Bs ; heat exchange rate between water and soil(ly/min)

  • PDF

고로쇠나무(Acer Mono)의 수액출수에 미치는 환경요인과 그 군락의 자원화에 관한 연구 (2): 환경요인 및 공시목의 회복 (Studies on the Environmental Factors for Sap Exudation of Acer mono and the Resource Development of its Community (2): Environmental Factors and Tree Recovery)

  • Kim, Chul-Soo;Kwak, Ae-Kyung
    • The Korean Journal of Ecology
    • /
    • 제17권4호
    • /
    • pp.533-545
    • /
    • 1994
  • The bleeding of 39 Acer mono trunks by wounding was investigated at the altitudes of 400m, 500m, 800m, and 1100m on Wangsirobong (1,214m), Mt. Chiri area (127°34'E., 35°14'N.) from February 4 to March 21, 1993 and from February 23 to March 23, 1994. The amount of sap in a day was clodely related to the change of air temperature and wind speed. Especially, the abundant sap was exudated at the ranges of -4~13℃ in the daily range of temperature and it was below 0.14m/s in wind speed. The most abundant bleeding was exudated from Acer mono trunk located south facing slope in 800m altitude. Also the amount of sap increased with incereasing suface area of crown. The maximum bleeding of sap was collected from the hole punctured at 80cm height from the ground surface at southern part of the trunks. And the number of exudation holes had an important effect on bleeding of sap but the number of holes should be controlled by DBH of trunks. These results suggested that the exudation was influenced by the daily range of temperature and wind speed. And the altitude, direction of sloped where the trees occurred, surface area of crown, the number of exudation holes, height form the ground surface and the direction of the hole was 91.6% when germicide (Dimethyl-4,4' -ophenylene bis 3-thio alonate) was treated from April to October after bleeding of sap in the year.

  • PDF

부산지역 미세먼지 농도 분포에 따른 기상요소 분석 (Analysis on Meteorological Factors related to the Distribution of PM10 Concentration in Busan)

  • 김민경;정우식;이화운;도우곤;조정구;이귀옥
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1213-1226
    • /
    • 2013
  • $PM_{10}$ concentration is related to the meteorological variables including to local and synoptic meteorology. In this study the $PM_{10}$ concentrations of Busan in 2007~2011 were analyzed and the days of yellow sand or rainfall which is more than 5 mm were excluded. The sections of $PM_{10}$ concentration were divided according to 10-quantiles, quartiles and 90-quantiles. The 90-quantiles of daily $PM_{10}$ concentration were selected as high concentration dates. In the high concentration dates the daily mean averaged cloudness, mean daily surface wind speed, daily mean surface pressure and PBL height were low and diurnal variation of surface pressure and daily maximum surface temperature were high. When the high $PM_{10}$ dates occurred, the west and south wind blew on the ground and the west wind blew strongly on the 850 hPa. So it seemed that long range transboundary air pollutants made effects on the high concentration dates. The cluster analysis using Hysplit model which is the backward trajectory was made on the high concentration dates. As a result, 3 clusters were extracted and on the short range transboundary cluster the daily mean relative humidity and cloudness were high and PBL height was low.

한라산 아고산대의 동결기 기온 및 지온변화 (Variationsin Air and Ground Temperatures During a Frozen Season in the Subalpine Zone of Mt. Halla)

  • 김태호
    • 한국지형학회지
    • /
    • 제20권3호
    • /
    • pp.95-107
    • /
    • 2013
  • 한라산 아고산대 표고 1,710m 지점의 나지에서 동결기를 중심으로 212일간 지상 55cm 높이의 기온과 지중 2cm, 10cm 및 20cm 깊이의 지온을 관측하여 주빙하성 지형형성환경을 조사하였다. 관측기간의 평균기온은 $-0.1^{\circ}C$이며, 깊이별 평균지온은 2cm $1.8^{\circ}C$, 10cm $2.6^{\circ}C$, 20cm $3.2^{\circ}C$이다. 2cm 깊이에서는 1월부터 3월까지 영하의 월평균지온이 관측되었으나 다른 깊이에서는 출현하지 않았다. 동결융해 사이클의 출현횟수는 55cm 높이에서 72회인 반면 지중 2cm 깊이에서 17회, 10cm 깊이에서 8회, 20cm 깊이에서 3회로 지중으로 내려가면서 크게 감소하였다. 지상과 2cm 깊이에서의 동결융해는 일일 주기가 탁월한 반면 10cm와 20cm 깊이에서는 수일 주기로 출현하였다. 또한 2cm 깊이에서 12월 중순~4월 중순, 10cm 깊이에서 2월 말~4월 중순, 20cm 깊이에서 4월 초순~중순에 일평균지온이 대체로 $0^{\circ}C$ 밑으로 내려가는 계절적 동결기가 출현하였다. 관측지점은 1월부터 4월 초순까지 55cm 이상의 눈으로 덮여 있다가 4월 16일에 전부 사라졌다. 12월 하순 2cm 깊이에 형성된 계절적 동토층은 적설의 단열효과로 인하여 3월 말~4월 초에 10cm 깊이에 도달하였다. 4월 7일부터 14일까지 깊이 20cm를 넘는 최대동결심을 보이나 이후 급속하게 융해되어 17일 이후 계절적 동토층은 출현하지 않았다. 융해진행기에도 잔설이 남아 있는 관측지점에는 융해진행기보다 동결진행기에 주빙하 프로세스가 더 탁월하게 진행되며, 일주기성 동결융해 사이클의 발생심도와 최대동결심을 고려하면 한라산 아고산대의 사면물질이동은 주로 동상포행에 의해 발생한다.

Investigation of Vertical Profiles of Meteorological Parameters and Ozone Concentration in the Mexico City Metropolitan Area

  • Benitez-Garcia, Sandy E.;Kanda, Isao;Okazaki, Yukiyo;Wakamatsu, Shinji;Basaldud, Roberto;Horikoshi, Nobuji;Ortinez, Jose A.;Ramos-Benitez, Victor R.;Cardenas, Beatriz
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권2호
    • /
    • pp.114-127
    • /
    • 2015
  • In the Mexico City Metropolitan Area (MCMA), ozone ($O_3$) concentration is still higher than in other urban areas in developed countries. In order to reveal the current state of photochemical air pollution and to provide data for validation of chemical transport models, vertical profiles of meteorological parameters and ozone concentrations were measured by ozonesonde in two field campaigns: the first one, during the change of season from wet to dry-cold (November 2011) and the second during the dry-warm season (March 2012). Unlike previous similar field campaigns, ozonesonde was launched twice daily. The observation data were used to analyze the production and distribution of ozone in the convective boundary layer. The observation days covered a wide range of meteorological conditions, and various profiles were obtained. The evolution of the mixing layer (ML) height was analyzed, revealing that ML evolution was faster during daytime in March 2012 than in November 2011. On a day in November 2011, the early-morning strong wind and the resulting vertical mixing was observed to have brought the high-ozone-concentration air-mass to the ground and caused relatively high surface ozone concentration in the morning. The amount of produced ozone in the MCMA was estimated by taking the difference between the two profiles on each day. In addition to the well-known positive correlation between daily maximum temperature and ozone production, effect of the ML height and wind stagnation was identified for a day in March 2012 when the maximum ground-level ozone concentration was observed during the two field campaigns. The relatively low ventilation coefficient in the morning and the relatively high value in the afternoon on this day implied efficient accumulation of the $O_3$ precursors and rapid production of $O_3$ in the ML.

한반도를 포함한 동아시아 영역에서 오존전량과 유해자외선의 특성과 예측 (Characteristics and Prediction of Total Ozone and UV-B Irradiance in East Asia Including the Korean Peninsula)

  • 문윤섭;민우석;김유근
    • 한국환경과학회지
    • /
    • 제15권8호
    • /
    • pp.701-718
    • /
    • 2006
  • The average ratio of the daily UV-B to total solar (75) irradiance at Busan (35.23$^{\circ}$N, 129.07$^{\circ}$E) in Korea is found as 0.11%. There is also a high exponential relationship between hourly UV-B and total solar irradiance: UV-B=exp (a$\times$(75-b))(R$^2$=0.93). The daily variation of total ozone is compared with the UV-B irradiance at Pohang (36.03$^{\circ}$N, 129.40$^{\circ}$E) in Korea using the Total Ozone Mapping Spectrometer (TOMS) data during the period of May to July in 2005. The total ozone (TO) has been maintained to a decreasing trend since 1979, which leading to a negative correlation with the ground-level UV-B irradiance doting the given period of cloudless day: UV-B=239.23-0.056 TO (R$^2$=0.52). The statistical predictions of daily total ozone are analyzed by using the data of the Brewer spectrophotometer and TOMS in East Asia including the Korean peninsula. The long-term monthly averages of total ozone using the multiplicative seasonal AutoRegressive Integrated Moving Average (ARIMA) model are used to predict the hourly mean UV-B irradiance by interpolating the daily mean total ozone far the predicting period. We also can predict the next day's total ozone by using regression models based on the present day's total ozone by TOMS and the next day's predicted maximum air temperature by the Meteorological Mesoscale Model 5 (MM5). These predicted and observed total ozone amounts are used to input data of the parameterization model (PM) of hourly UV-B irradiance. The PM of UV-B irradiance is based on the main parameters such as cloudiness, solar zenith angle, total ozone, opacity of aerosols, altitude, and surface albedo. The input data for the model requires daily total ozone, hourly amount and type of cloud, visibility and air pressure. To simplify cloud effects in the model, the constant cloud transmittance are used. For example, the correlation coefficient of the PM using these cloud transmissivities is shown high in more than 0.91 for cloudy days in Busan, and the relative mean bias error (RMBE) and the relative root mean square error (RRMSE) are less than 21% and 27%, respectively. In this study, the daily variations of calculated and predicted UV-B irradiance are presented in high correlation coefficients of more than 0.86 at each monitoring site of the Korean peninsula as well as East Asia. The RMBE is within 10% of the mean measured hourly irradiance, and the RRMSE is within 15% for hourly irradiance, respectively. Although errors are present in cloud amounts and total ozone, the results are still acceptable.

대기환경영향평가를 위한 대구광역시 상인동 달비골의 봄철 기상관측 사례분석 (A Case Study on the Meteorological Observation in Spring for the Atmospheric Environment Impact Assessment at Sangin-dong Dalbi Valley, Daegu)

  • 박종길;정우식;황수진;윤일희;박길운;김신호;김석철
    • 한국환경과학회지
    • /
    • 제17권9호
    • /
    • pp.1053-1068
    • /
    • 2008
  • This study aims to produce fundamental database for Environment Impact Assessment by monitoring vertical structure of the atmosphere due to the mountain valley wind in spring season. For this, we observed surface and upper meteorological elements in Sangin-dong, Daegu using the rawinsonde and automatic weather system(AWS). In Sangin-dong, the weather condition was largely affected by mountains when compared to city center. The air temperature was low during the night time and day break, and similar to that of city center during the day time. Relative humidity also showed similar trend; high during the night time and day break and similar to that of city center during the day time. Solar radiation was higher than the city, and the daily maximum temperature was observed later than the city. The synoptic wind during the measurement period was west wind. But during the day time, the west wind was joined by the prevailing wind to become stronger than the night time. During the night time and daybreak, the impact of mountain wind lowered the overall temperature, showing strong geographical influence. The vertical structure of the atmosphere in Dalbi valley, Sangin-dong had a sharp change in air temperature, relative humidity, potential temperature and equivalent potential temperature when measured at the upper part of the mixing layer height. The mixing depth was formed at maximum 1896m above the ground, and in the night time, the inversion layer was formed by radiational cooling and cold mountain wind.