• Title/Summary/Keyword: Daily Maximum Air Temperature

Search Result 134, Processing Time 0.021 seconds

Impacts of Urban High Temperature Events on Physiology of Apple Trees: A Case Study of 'Fuji'/M.9 Apple Trees in Daegu, Korea (도심지역 고온현상이 사과나무 생육과정에 미치는 영향: 대구광역시 '후지'/M.9을 사례로)

  • Sagong, Dong-Hoon;Kweon, Hun-Joong;Park, Moo-Yong;Song, Yang-Yik;Ryu, Su-Hyun;Kim, Mok-Jong;Choi, Kyung-Hee;Yoon, Tae-Myung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.3
    • /
    • pp.130-144
    • /
    • 2013
  • In this study, we examined the effect of high temperature of urban area on the physiological response of apple tree including the photosynthesis, shoot growth, and fruit quality of 'Fuji'/M.9 apple trees planted at Daegu urban area (DUA) and Gunwi rural area (GRA) for 2 years (2009-2010). During the apple growing season (April-October), the average air temperature of DUA was about $3.0^{\circ}C$ higher than that of GRA and the total rainfall of DUA was 130 mm more than that of GRA. During fruit enlargement stage (June-August), the number of days that recorded daily mean temperature of over $30^{\circ}C$ were ten on DUA in 2010, but there was no day when such temperature was experienced in 2009. Average air temperature of DUA during the maturation stage (September-October) was $19.8^{\circ}C$, which was $4.0^{\circ}C$ higher than that of GRA. The higher temperature of over $30^{\circ}C$ during fruit enlargement stage decreased the photosynthetic rate, shoot growth, fruit weight, and soluble solid content of 'Fuji'/M.9 apple tree. The moderate temperature of about $20^{\circ}C$ during maturation stage increased the photosynthetic rate and soluble solid content of 'Fuji'/M.9 apple tree, but decreased fruit red color. In regional comparison with GRA, photosynthetic rate of DUA was changed from lower before rainy season to higher after rainy season. Fruit weight was higher in DUA than that of GRA. However, fruit weight between DUA and GRA did not show the difference when accumulated days that recorded daily maximum temperature over $35^{\circ}C$ of DUA was increased. Compared to the GRA, soluble solid content of DUA was higher, but fruit red color of DUA was less. These results indicate that the poor red coloring is the most problematic in 'Fuji'/M.9 apple tree by global warming and urbanization.

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Air Temperature And Leaf Growth of Several Woody Plants in Early Gruwing Season (수 종 목본식물의 생육초기 기온과 잎의 생장)

  • 민병미
    • The Korean Journal of Ecology
    • /
    • v.17 no.1
    • /
    • pp.49-58
    • /
    • 1994
  • To investigate the relationship between leaf growth of several woody plants and ait tempera ture in early growing season (from April to June) in deciduous forests, I surveyed the changes of leaf area (LA), leaf weight (LW) and specific leaf area (SLA) of 19 specles, in two areas Namhansansung (NA) and Taegwallyong (TA) area in which that the latitudes are similer ($37^{\circ}28'N$ at NA and $37^{\circ}27'N$ an TA), but annual mean-temperatures were different ($11.8^{\circ}C\;in\;NA, \;6.3^{\circ}C$ in TA) for two years, 1991 and 1992. In the same species, the plants of NA began to grow 10-25 days earlier than those of TA, but the latter grew faster than the former. On 10 June the values of LA and LW per leaf were similar in the two areas but the maximum values of SLA were higher in NA. In the same plant, the values of LA and LW were constant year by year, except for PYIOLUS leveilleana, Quercus mongolica, Symplocos chznensis for. pilosa and S t y a r ubussiu. In N A , the leaves be gan to grow during the first ten days of April, and eariler in 1992 than in 1991, and daily mean temperature (DMT) of the former from 27 March to 6 April were higher than those of thc latter. But the LA increased faster in 1991 than in 1992. and DMT from 10 April to 16 April were higher in 1991 than in 1992.

  • PDF

The Nopsae;a Foehn type wind over the Young Suh region of central Korea (영서지방의 푄현상)

  • ;Lee, Hyon-Young
    • Journal of the Korean Geographical Society
    • /
    • v.29 no.3
    • /
    • pp.266-280
    • /
    • 1994
  • Upper-air synoptic data and surface weather elements such as temperature, relative humidity, wind speed, cloud and precipitation were analyzed in some detail to determine the characteristics of Nopsae, a foehn-like surface wind over the Youngsuh region of Central Korea. NOAA AVHRR and GMS images are also referenced to identify the distribution of clouds and precipitation to classify the tpyes of foehn over the study area. The data period examined is from 1982 until 1993 of spring and summer months from March through August. Results of the anaylsis are as follows. Warm and dry air penetration over the Younesuh region has experienced on foehn days occured between March 21 and August 10 during study perion. The mean annual number of foehn the days were 28. Foehn phenomena were prominent during March 21-25, April 5-15, May 25-June 10, and June 26-30 pentads. The intensity of the phenomena can be evaluated as the difference of daily maximum temperature and relative humidity between windward sites and leeward sites. The intensity of daily maximum temperature reached 14.5$^{\circ}C$, but most values were in the range of 5.0-7.5$^{\circ}C$ (61%). Although strong intensity of foehns usually develop in June, it is common that farmers in the region experince more aridity during the foehnday of April and May due to the transplantation of rice seedlings. Long-run foehn are not common phenomena and 55% of foehn terminate in one day, but there is a record that Nopsae persisted up to 9 days continuously. The author identified using the cloud and precipitation data out of NOAA-11, AVHRR and GMS images is that one of them has no precipitation over windward side. The available data and the results of the analysis are somewhat inadequate. Since the results imply that wave phenomenon is potentially important in terms of local surface weather and vertical momentum transport, more detailed theoretical and observational studies are necessary to clarify the mechanism and the impacts of Nopsae.

  • PDF

The Effects of Pergola Wisteria floribunda's LAI on Thermal Environment (그늘시렁 Wisteria floribunda의 엽면적지수가 온열환경에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.115-125
    • /
    • 2017
  • This study was to investigate the user's thermal environments under the pergola($L\;7,200{\times}W\;4,200{\times}H\;2,700mn$) covered with Wisteria floribunda(Willd.) DC. according to the variation of leaf area index(LAI). We carried out detailed measurements with two human-biometeorological stations on a popular square Jinju, Korea($N35^{\circ}10^{\prime}59.8^{{\prime}{\prime}}$, $E\;128^{\circ}05^{\prime}32.0^{{\prime}{\prime}}$, elevation: 38m). One of the stations stood under a pergola, while the other in the sun. The measurement spots were instrumented with microclimate monitoring stations to continuously measure air temperature and relative humidity, wind speed, shortwave and longwave radiation from the six cardinal directions at the height of 0.6m so as to calculate the Universal Thermal Climate Index(UTCI) from $9^{th}$ April to $27^{th}$ September 2017. The LAI was measured using the LAI-2200C Plant Canopy Analyzer. The analysis results of 18 day's 1 minute term human-biometeorological data absorbed by a man in sitting position from 10am to 4pm showed the following. During the whole observation period, daily average air temperatures under the pergola were respectively $0.7{\sim}2.3^{\circ}C$ lower compared with those in the sun, daily average wind speed and relative humidity under the pergola were respectively 0.17~0.38m/s and 0.4~3.1% higher compared with those in the sun. There was significant relationship in LAI, Julian day number and were expressed in the equation $y=-0.0004x^2+0.1719x-11.765(R^2=0.9897)$. The average $T_{mrt}$ under the pergola were $11.9{\sim}25.4^{\circ}C$ lower and maximum ${\Delta}T_{mrt}$ under the pergola were $24.1{\sim}30.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average $T_{mrt}$ compared with those in the sun and was expressed in the equation $y=0.0678{\ln}(x)+0.3036(R^2=0.9454)$. The average UTCI under the pergola were $4.1{\sim}8.3^{\circ}C$ lower and maximum ${\Delta}UTCI$ under the pergola were $7.8{\sim}10.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average UTCI compared with those in the sun and were expressed in the equation $y=0.0322{\ln}(x)+0.1538(R^2=0.8946)$. The shading by the pergola covered with vines was very effective for reducing daytime UTCI absorbed by a man in sitting position at summer largely through a reduction in mean radiant temperature from sun protection, lowering thermal stress from very strong(UTCI >$38^{\circ}C$) and strong(UTCI >$32^{\circ}C$) down to strong(UTCI >$32^{\circ}C$) and moderate(UTCI >$26^{\circ}C$). Therefore the pergola covered with vines used for shading outdoor spaces is essential to mitigate heat stress and can create better human thermal comfort especially in cities during summer. But the thermal environments under the pergola covered with vines during the heat wave supposed to user "very strong heat stress(UTCI>$38^{\circ}C$)". Therefore users must restrain themselves from outdoor activities during the heat waves.

The Effects of Air-Temperatures on the Growth of Tillering Stage of Rice (분얼기의 기온이 수도 생육량에 미치는 영향)

  • Seog-Hong Park;Eun-Woong Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.14
    • /
    • pp.47-51
    • /
    • 1973
  • In order to ascertain the effects of fluctuations and range of daily temperatures on the growth of rice, a pot(1/5, 000 are) experiment was conducted in the phytotron, Crop Experiment Station, in 1972. Seven treatment combinations of day-temperatures 25 and $30^{\circ}C$ with night-temperatures 10, 15, 20 and $25^{\circ}C$ were applied in three 10 days periods, in to which the tillering stage was split after rooting of the paddy, namely, early, middle and late. The results may be summarized as follows: 1. The number of tillers were maximum with the treatments of day-temperature $30^{\circ}C$ and night-temperatures 20 as well as $25^{\circ}C$ in the early and middle periods, while the effects were small in the late period. 2. Multiplying plant height and number of panicles resulted in a high figure by combining a day-temperature of $30^{\circ}C$ with night-temperatures 20 as well as $25^{\circ}C$ in the early and middle periods, and no differences in the late period. 3. The treatment in the early period yielded a high RGR(g/g/day), of which the treatment combinations of day-temperature $30^{\circ}C$ with night-temperatures 20 and $25^{\circ}C$ gave the highest figure. 4. High straw weight in ripening stage was obtained with the temperature treatments in the early period rather than those in the late period. 5. Accordingly, it seems that the effect of temperature on the emergence of tillers is the highest at the early stage of tillering.

  • PDF

Effect of Soluble-silicate or Chitosan Foliar Spray on Ginseng Cultivated in Blue-white Plastic Film House

  • Seo, Sang Young;Cho, Jong hyeon;Kim, Chang Su;Kim, Hyo Jin;Kim, Dong Won;An, Min Sil;Jang, In Bae
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.46-46
    • /
    • 2019
  • The experiments were performed in the Jinan (elevation: 300 meters above sea level), Jeollabuk-do. Seedlings (n = 63 per $3.3m^2$) of ginseng cultivar (Cheonpung, Yeonpung) were planted on April 10, 2015. Shading material of plastic film house was blue-white film. Before the Planting seedling, silicate (3 kg/10 a) or chitosan (40 kg/10 a) was fertilized and foliar sprayed on the leaves 1000 times dilution solution once a month from May to September every year. The growth results of 5-year old ginseng surveyed in 2018 are as follows. The average air temperature in the plastic film house was the highest at $26.6^{\circ}C$ and $26.5^{\circ}C$ in July and August, respectively, and the highest temperature was $40.5^{\circ}C$ in July. The maximum daily temperature of $35^{\circ}C$ or more was 30 days, with the average soil temperature being $24.9^{\circ}C$ in August. The chemical properties of the test soil are as follows. pH was 6.4~6.9 level and EC was 0.35~0.46 dS/m. The organic matter content was 33.5~41.4 g/kg, and available-P content was 251.9~306.8 mg/kg. Exchangeable cations contents, such as K, Ca and Mg were all the appropriate ranges. The soil microbial density surveyed by the dilution plate method was 10~50 times higher than that of control (Non-treatment) and actinomycete density was 3~6 times higher. Pathogens of the genus Fusarium by Metagenome analysis decreased 91.3% and 68.2% respectively in the foliar sprayed of chitosan and soluble-silicate. The light intensity (PAR) in the blue-white film plastic film house gradually increased until July and then decereased, with the average of light intensity in March-October was $120.3umol/m^2/s$. The growth of aerial parts such as plant height and stem length was better than non-sprayed group in silicate or chitosan treatments and Yeonpung cultivar was superior to the Cheonpung cultivar. The SPAD value was higher in Yeonpung cultivar foliar sprayed with soluble-silicate. The growth of underground parts such as root length and taproot length were better in chitosan and soluble-silicate treatment than control, especially in Yeonpung cultivar foliar sprayed with chitosan was good in taproot length and taproot diameter, and fresh weight of root was 60.1 g. Ginsenoside contents were 24.9 mg/g and 22.4 mg/g, in the Cheonpung cultivar foliar sprayed with soluble-silicate or chitosan respectively, 28% and 15% higher than control (19.5 mg/g). The incidence of disease by Alteraria panax and Botrytis cinerea was 3~9% and 4~9%, respectively. High temperature damage rate was 3~5%.

  • PDF

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House (단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가)

  • Baek, Namchoon;Han, Seunghyun;Lee, Wang Je;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.

Effect of Meteorological Factors on Evapotranspiration Change of Cnidium officinale Makino (기상요인이 일천궁의 증발산량 변화에 미치는 영향)

  • Seo, Young-Jin;Nam, Hyo-Hoon;Jang, Won-Cheol;Kim, Jong-Soo;Lee, Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.4
    • /
    • pp.366-375
    • /
    • 2018
  • Evapotranspiration (ET) information is needed for many applications in agricultural and environmental resource management because crop yields, plant growth and physiological characteristics are primarily water limited. This study was conducted to evaluate the diurnal change of ET using electronic weighing lysimeter and to determine whether the ET of Cnidium officinale Makino could be manipulated through meteorological factors such as solar radiation, windy conditions and air temperature etc., Pot has a diameter of 35 cm and an height of 38 cm. A disturbed soil of sandy loam (coarse, mixed, mesic family of Dystric Fluventic Eutroudepts) within lysimeter has a mass of approximately 40.0 kg. In 2017, 10-minute recordings of data were used for measuring actual ET, and also evaluating a relationship between ET and meteorological factors during from 2 Aug. to 6 Aug. The maximum daily ET of Cnidium officinale was $44.04{\pm}3.949g$ per hour in lysimetric measurements. Diurnal changes of ET was highly correlated with solar radiation ($r^2=0.7778$) and followed by wind speed ($r^2=0.6400$). But on the other hand, air temperature was not consistent with ET ($r^2=0.2260$). This results imply that ET of Cnidium officinaele seems to be mainly governed by radiation energy in clear days, and approximately 40% of solar radiation is likely to be converted into ET. Therefore, weighing lysimeter can be used to accurately estimate actual ET and is expected to attract a great deal of attention to reliable application of water management in agriculture.