• Title/Summary/Keyword: Da vinci surgical robot

Search Result 27, Processing Time 0.032 seconds

DaVinci SP-based simultaneous bilateral partial nephrectomy from the midline transperitoneal approach: a case report

  • Young Hwii Ko;Jong Gyun Ha;Jae Yoon Jang;Yeung Uk Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.1
    • /
    • pp.48-52
    • /
    • 2024
  • While simultaneous bilateral partial nephrectomy with a conventional multiport robot has been consistently reported since the 2010s, the introduction of the DaVinci SP system (Intuitive Surgical, Sunnyvale, CA, USA) could provide a novel way to perform surgery on bilateral kidneys while innovatively reducing the number of incisions. In our first report worldwide, the patient with bilateral small renal mass (2.0 cm for the left and 1.5 cm for the right side) and preoperative normal renal function was placed in the lateral decubitus position on an inverted bed. After tilting the bed to be as horizontal as possible, a 4-cm incision was made in the lower part of the umbilicus for the floating trocar technique. The partial nephrectomy was performed reliably as with the conventional transperitoneal approach, and then the patient could be repositioned to the contralateral side for the same procedure, maintaining all trocars. Total operation time (skin to skin), total console time, and the left- and right-side warm ischemic times were 260, 164, 27, and 23 minutes, respectively, without applying the early declamping technique. The estimated blood loss was 200 mL. The serum creatinine right after the operation, on the first day, 3 days, and 90 days after surgery were 0.92, 0.77, 0.79, and 0.81 mg/dL, respectively. For 90 days after the procedure, no complications or radiologic recurrence were observed. Further clinical studies will reveal the advantages of using the DaVinci SP device for this procedure over traditional multiport surgery, maximizing the benefit of a single port-based approach.

Initial Experience of Robot-assisted Resection of Choledochal Cyst in Children (소아 담관낭종의 로봇수술의 초기경험)

  • Chang, Eun-Young;Chang, Hye-Kyung;Ryu, Seon-Ae;Oh, Jung-Tak;Han, Seok-Joo
    • Advances in pediatric surgery
    • /
    • v.17 no.1
    • /
    • pp.72-80
    • /
    • 2011
  • Although laparoscopic surgery for hepatobiliary disease in children is possible, it is technically challenging. In an attempt to overcome these difficulties, the da Vinci Robotic Surgical System$^{(R)}$ was used to facilitate the minimally invasive treatment of choledochal Cyst in six children. In early consecutive three cases, we experienced three complications; a case of laparotomy conversion, a case of late stenosis of the hepaticojejunostomy, and a case of leakage from a hepaticojejunostomy. However, in the last three cases the complete resection of the choledochal cyst and Roux-en-Y hepaticojejunostomy were performed using the robotic surgical system without complication. We think robot-assisted choledochal cyst resection in children appears safe and feasible, and may increase the variety of complex procedures in pediatric surgical fields.

  • PDF

Development of a Robotic Surgery System using General Purpose Robotic Arm and Modular Haptic Controller (범용 로봇팔과 모듈러 햅틱 컨트롤러를 사용한 수술 로봇 시스템 개발)

  • Yi, Jae-Bong;Jin, Sangrok;Yi, Seung-Joon
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.2
    • /
    • pp.131-138
    • /
    • 2020
  • This paper proposes a low-cost robotic surgery system composed of a general purpose robotic arm, an interface for daVinci surgical robot tools and a modular haptic controller utilizing smart actuators. The 7 degree of freedom (DOF) haptic controller is suspended in the air using the gravity compensation, and the 3D position and orientation of the controller endpoint is calculated from the joint readings and the forward kinematics of the haptic controller. Then the joint angles for a general purpose robotic arm is calculated using the analytic inverse kinematics so that that the tooltip reaches the target position through a small incision. Finally, the surgical tool wrist joints angles are calculated to make the tooltip correctly face the desired orientation. The suggested system is implemented and validated using the physical UR5e robotic arm.

The Present and Future of Robotic Surgery (로봇수술의 현재와 미래)

  • Rha, Koon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.68-70
    • /
    • 2008
  • Since the beginning of the 21st century, the emergence of innovative technologies made further advances in minimal access surgery possible. Robotic surgery and telepresence surgery effectively addressed the limitations of laparoscopic procedures, thus revolutionizing minimal access surgery. Surgical robots provide surgeons with to technologically advanced vision and hand skills. As a result, such systems are expected to revolutionize the field of surgery. In that time, much progress has been made in integrating robotic technologies with surgical instrumentation. However, robotic surgery will not only require special training, but it will also change the existing surgical training pattern and reshape the learning curve by offering new solutions, such as robotic surgical simulators and robotic telementoring. This article provides an introduction to medical robotic technologies, develops a possible classification, reviews the evolution of a surgical robot, and discusses future prospects for innovation. In the future, surgical robots should be smaller, less expensive, easier to operate, and should seamlessly integrate emerging technologies from a number of different fields. We believe that, in the near future as robotic technology continues to develop, almost all kinds of endoscopic surgery will be performed by this technology.

  • PDF

Robot-Assisted Repair of Atrial Septal Defect: A Comparison of Beating and Non-Beating Heart Surgery

  • Yun, Taeyoung;Kim, Hakju;Sohn, Bongyeon;Chang, Hyoung Woo;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • Background: Robot-assisted repair of atrial septal defect (ASD) can be performed under either beating-heart or non-beating-heart conditions. However, the risk of cerebral air embolism (i.e., stroke) is a concern in the beating-heart approach. This study aimed to compare the outcomes of beating- and non-beating-heart approaches in robot-assisted ASD repair. Methods: From 2010 to 2019, a total of 45 patients (mean age, 43.4±14.6 years; range, 19-79 years) underwent ASD repair using the da Vinci robotic surgical system. Twenty-seven of these cases were performed on a beating heart (beating-heart group, n=27) and the other cases were performed on an arrested or fibrillating heart (non-beating-heart group, n=18). Cardiopulmonary bypass (CPB) was achieved via cannulation of the femoral vessels and the right internal jugular vein in all patients. Results: Complete ASD closure was verified using intraoperative transesophageal echocardiography in all patients. Conversion to open surgery was not performed in any cases, and there were no major complications. All patients recovered from anesthesia without any immediate postoperative neurologic symptoms. In a subgroup analysis of isolated ASD patch repair (beating-heart group: n=22 vs. non-beating-heart group: n=5), the operation time and CPB time were shorter in the beating-heart group (234±38 vs. 253±29 minutes, p=0.133 and 113±28 vs. 143±29 minutes, p=0.034, respectively). Conclusion: Robot-assisted ASD repair can be safely performed with the beating-heart approach. No additional risk in terms of cerebral embolism was found in the beating-heart group.

Salvage Transoral Robotic Surgery for Recurrent or Residual Head and Neck Squamous Cell Carcinoma: A Single Institution Experience

  • Dabas, Surender;Dewan, Abhinav;Ranjan, Reetesh;Dewan, Ajay Kumar;Shukla, Himanshu;Sinha, Rupal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7627-7632
    • /
    • 2015
  • Background: The present study was conducted to evaluate the technical feasibility, safety and adequacy of surgical margins with salvage transoral robotic surgery (TORS) for recurrent or residual head and neck squamous cell carcinoma patients. Materials and Methods: Thirty patients who underwent salvage TORS using the 'DaVinci' robot were enrolled in the study and data related to their surgical time, complications and functional outcome were recorded. Results: The feasibility of salvage TORS in our study was observed to be 100%. Positive margins were encountered in only 6.7% of patients. Mean blood loss was 23.3 ml with no patient requiring blood transfusion. Postoperative complications in the form of primary haemorrhage requiring active surgical intervention occurred in 13.3%. Oral feeding could be started as early as the 3rd postoperative day in a few patients, with nasogastric tubes being removed on the 12th postoperative day. Long term gastrostomy tube dependency was seen in 10% cases. Median survival of patients was 19 months. Conclusions: Salvage TORS is a safe, effective and feasible option in the management of treatment failure cases. It offers an alternative surgical approach with unexpected benefits in terms of tracheostomy tube use, Ryle's tube and gastrostomy dependence.

Successful Robotic Gastrectomy Does Not Require Extensive Laparoscopic Experience

  • An, Ji Yeong;Kim, Su Mi;Ahn, Soohyun;Choi, Min-Gew;Lee, Jun-Ho;Sohn, Tae Sung;Bae, Jae-Moon;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.90-98
    • /
    • 2018
  • Purpose: We evaluated the learning curve and short-term surgical outcomes of robot-assisted distal gastrectomy (RADG) performed by a single surgeon experienced in open, but not laparoscopic, gastrectomy. We aimed to verify the feasibility of performing RADG without extensive laparoscopic experience. Materials and Methods: Between July 2012 and December 2016, 60 RADG procedures were performed by a single surgeon using the da $Vinci^{(R)}$ Surgical System (Intuitive Surgical). Patient characteristics, the length of the learning curve, surgical parameters, and short-term postoperative outcomes were analyzed and compared before and after the learning curve had been overcome. Results: The duration of surgery rapidly decreased from the first to the fourth case; after 25 procedures, the duration of surgery was stabilized, suggesting that the learning curve had been overcome. Cases were divided into 2 groups: 25 cases before the learning curve had been overcome (early cases) and 35 later cases. The mean duration of surgery was 420.8 minutes for the initial cases and 281.7 minutes for the later cases (P<0.001). The console time was significantly shorter during the later cases (168.6 minutes) than during the early cases (247.1 minutes) (P<0.001). Although the volume of blood loss during surgery declined over time, there was no significant difference between the early and later cases. No other postoperative outcomes differed between the 2 groups. Pathology reports revealed the presence of mucosal invasion in 58 patients and submucosal invasion in 2 patients. Conclusions: RADG can be performed safely with acceptable surgical outcomes by experts in open gastrectomy.