• Title/Summary/Keyword: DUMP

Search Result 344, Processing Time 0.03 seconds

The Development of Hazardous Waste Compact Dump incinerator for Low Emissions (저공해 compact 유해폐기물 dump 소각기 개발)

  • 전영남;채종성;정오진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.653-663
    • /
    • 2000
  • A lot of hazardous wastes are discharged as by-products of working process by industrial development. Hazardous wastes is physical characteristics of difficult destruction at hight temperature. Numerical simulation and combustion experiment performed of dump incinerator for hazardous waste incineration. For the numerical simulation, the SIMPLEST algorithm was used to ensure rapid converge A K-$\varepsilon$ model was incorporate for the enclosure of turbulence flow. Combustion model was used by ESCRS (extended simple chemically reacting system) model available of CHEMKIN thermodynamic data for the source term of species conservation equation or energy equation. Radiation model is used by six flux model. A parametric screening studies was carried out through numerical simulation and experiment. Residence time and concentration in the incinerator was strongly dependent on the parameters of mixture velocity, mixture equilibrium ratio, surrogate velocity and surrogate equilibrium ratio.

  • PDF

Numerical Analysis of the Seepage from and Stability of a Mine Waste-dump Slope during Rainfall (강우시 광산폐기물 적치사면의 침투 및 안정성에 대한 수치해석)

  • Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.57-66
    • /
    • 2015
  • A numerical analysis was performed of the seepage from and stability of a mine waste-dump slope in Imgi, Busan, considering rainfall intensity. The 40-45° slope angle of the waste dump is relatively steep, and the depth of the waste dump down to bedrock is 7-8 m. The groundwater level was 6.6 m below the surface. Various laboratory tests on samples obtained from the waste dump were performed to determine the input data for seepage and stability analyses of the waste-dump slope during rainfall. The results of seepage analysis for various rainfall intensities using the SEEP/W program show that the wetting front moved down with increasing rainfall duration. When the rainfall intensity was > 50 mm/ hour and the duration was > 24 hours, the waste dump became fully saturated because the wetting front reached the groundwater level. The results of slope stability analysis coupled with seepage analysis using the SLOPE/W program show that the safety factor of the slope decreased as the wetting front moved down due to rainfall infiltration. After continuous rainfall for 5-6 hours, the safety factor of the slope suddenly decreased but then recovered and converged. The sudden decrease was induced by an increase in pore-water pressure and a decrease in matric suction down to a certain depth as the wetting front approached the potential sliding surface.

Creation of Vector Network Data with Considering Terrain Gradient for Analyzing Optimal Haulage Routes of Dump Trucks in Open Pit Mines (노천광산 덤프트럭의 최적 운반경로 분석을 위한 지형경사가 고려된 벡터 네트워크 자료의 생성 방법)

  • Park, Boyoung;Choi, Yosoon;Park, Han-Su
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.353-361
    • /
    • 2013
  • Previous studies for analyzing optimal haulage routes of dump trucks in open pit mines mostly used raster data. However, the raster data has several problems in performing optimal route analyses: (1) the jagged appearance of haulage roads according the cell resolution often causes overestimation of the travel cost; (2) it difficult to trace the topological relationships among haulage roads. These problems can be eliminated by using vector network data, however a new method is required to reflect the performance characteristics of a dump truck according to terrain gradient changes. This study presents a new method to create vector network data with the consideration of terrain gradient for analyzing optimal haulage routes of dump trucks in open pit mines. It consists of four procedures: (a) creating digital elevation models, (b) digitizing haulage road networks, (c) calculating the terrain gradient of haulage roads, and (d) calculating the average speed and travel time of a dump truck along haulage roads. A simple case study at the Roto South pit in the Pasir open pit coal mine, Indonesia is also presented to provide proof that the proposed method is easily compatible to ArcGIS Network Analyst software and is effective in finding optimal haulage routes of dump trucks with considering terrain gradient in open pit mines.

High Performance Switched Reluctance Motor Drive for Automobiles using C-dump Converters

  • Song Sang-Hoon;Yoon Yong-Ho;Lee Tae-Won;Kim Yeun-Chung;Won Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.992-996
    • /
    • 2004
  • Small electric motors in an automobile perform various tasks such as engine cooling, pumping, and in heating, ventilating, and air-conditioning (HVAC) system. At present, most of dc motors are supplied by 12V or 24V batteries. However, DC motors surfer from lack of efficiency, low life cycles and unreliability. Therefore, there is a growing interest in substituting DC motors for advanced AC motors including switched reluctance motors. Although there are several other forms SRM converters, they are either unsatisfactory to the control performance or unsuitable for the 12V-battery powered 3-phase SRM drives. Taking into account the requirement for effective operation and simplicity structure of converter in the limited internal environment of automobiles, the author inclines toward selecting the modified C-dump converter as well as the energy efficient C-dump converter. This is so that more economical and efficient converter topology in automobile industries can be utilized. This paper describes the foundation for the design and development of a 12V-250W-3000rpm SRM drives for automobiles. Furthermore, complete circuit, computer simulation and experiment results are presented to verify the performance of the C-dump converters.

  • PDF

High performance operation of SRM by Resonant C-dump Converter (공진형 C-dump컨버터에 의한 SRM의 고성능 운전)

  • Jeong Kyun-Ha;Yoon Yong-Ho;Kim Se-Joo;Won Chung-Yuen;Kim Young-real
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.28-32
    • /
    • 2004
  • In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on conventional C-dump converter topology and the proposed resonant C-dump converter topology Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

  • PDF

Pre-detection Parameter of the Combustion Instabilities in the Gas Turbine Combustor (덤프형 가스터빈 연소기에서의 화염 불안정성의 사전 감지 인자)

  • Lee, Byeong-Jun;Santavicca, D.A.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.750-756
    • /
    • 2002
  • The effect of equivalence ratio and velocity on the stability of flame in dump combustor was studied in an atmospheric pressure, laboratory scathe dump combustor operating natural gas. Traditionally, peak-to-peak pressure, fluctuation of the heat release rate and Rayleigh index were used to find and control the combustion instability. Cross correlation coefficients, Ci,j which is defined as the normalized value of the integration of the product of two of the mixer pressure, dump plane pressure and heat release rate, are introduced to see whether the flame is stable or not. Ci,j shows more sensitive to combustion status than Rayleigh index in steadily burning flame. Also, the result indicates that the amplitude of Ci,j between heat release and mixer pressure goes up before the flame at the rich de-stabilizing equivalence ratio near $\psi$=0.85. t means Ci:j at this case has a potential to detect the de-stablizing moment in prior to becoming unstable in dump combustor.

Fuzzy Logic Based Energy Management For Wind Turbine, Photo Voltaic And Diesel Hybrid System

  • Talha, Muhammad;Asghar, Furqan;Kim, Sung Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.351-360
    • /
    • 2016
  • Rapid population growth with high living standards and high electronics use for personal comfort has raised the electricity demand exponentially. To fulfill this elevated demand, conventional energy sources are shifting towards low production cost and long term usable alternative energy sources. Hybrid renewable energy systems (HRES) are becoming popular as stand-alone power systems for providing electricity in remote areas due to advancement in renewable energy technologies and subsequent rise in prices of petroleum products. Wind and solar power are considered feasible replacement to fossil fuels as the prediction of the fuel shortage in the near future, forced all operators involved in energy production to explore this new and clean source of power. Presented paper proposes fuzzy logic based Energy Management System (EMS) for Wind Turbine (WT), Photo Voltaic (PV) and Diesel Generator (DG) hybrid micro-grid configuration. Battery backup system is introduced for worst environmental conditions or high load demands. Dump load along with dump load controller is implemented for over voltage and over speed protection. Fuzzy logic based supervisory control system performs the power flow control between different scenarios such as battery charging, battery backup, dump load activation and DG backup in most intellectual way.

Hydraulic Properties of a Coastal Waste Dump in Pohang, Southeastern Korea (포항 지역 해안 투기 매립장의 수리 특성에 관한 연구)

  • 김윤영;강동근;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Coastal waste dump in Pohang is composed of slags and sludge of POSCO. Hydraulic parameters in the coastal waste dump are very different from those in municipal landfills and general unconsolidated or fractured aquifers. In the waste dump pumping or slug tests are not adequate for the estimation of hydraulic parameters. Time-lag and amplitude of the tidal fluctuation of groundwater table are used to determine the hydraulic parameters. Groundwater table at the groundwater observation wells is about 40 cm higher than the sea level. The contributing factors of the groundwater-rise are estimated. Vertical profile of some chemical constituents in groundwater indicates the gradual transition of the fresh groundwater at the uppermost position to the sea water at the bottom.

  • PDF

A Study on the Improvement of Combustion Performance in Dump type Ram-combustor Equipped for Flame-holder (Flame-holder를 장착한 Dump Type Ram-combustor의 연소성능 향상에 관한 연구)

  • 이대웅;윤현진;문수연;손창현;이충원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.43-46
    • /
    • 2001
  • In the experiment of dump type Ram-combustor equipped for flame-holder which is designed for development of combustion performance, temperature of center of exit decreases in the case of short length($L_c$=300mm) of combustor while does not decrease in the case of $L_c$=500mm and flame still remains under the center of combustor. With V-gutter, temperature distribution of exit becomes uniform. In the case of $L_c$=300mm, combustion efficiency of combustor with V-gutter increases a few but the influence of V-gutter is small.

  • PDF

Analyzed the performances for system withlimiter discriminator detection and integrate and dump post detection filtering (부분대역 재밍하에서 리미터-변별기 검파와 Integrate-and-Dump 펄터링을 고려한시스템의 성능 분석)

  • 이봉수;이사원
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.4
    • /
    • pp.78-85
    • /
    • 1998
  • In this paper, we analyzed the performances for FH/CPFSK system with limiter - discriminator detection and integrate-and-dump post-detection filtering under thermal noise and partial-band jamming noise. And, we considered intersymbol interference - related SNR and differential phase parameters for all eight of the possible adjacent bit data patterns, FM noise clicks for evaluating FH/CPFSK and CPFSK systems. In result, the optimum modulation index h was 0.7 and the optimum value of bandwidth-time product D was 1.0. Next, when we considered the thermal noise under the partial-band jamming, the thermal noise significantly influenced the error probability of system below 20dB approximately but could ignore above 20dB.

  • PDF