• Title/Summary/Keyword: DROP

Search Result 6,826, Processing Time 0.039 seconds

STUDIES ON THE DIMORPHISM AND TRANSITION OF BISEXUALITY OF HETEROSTYLOUS POLYGONACEAE (여뀌과 이형경식물의 Dinorphism과 Bisexuality의 변화)

  • Harn, Chang-Yawl
    • Journal of Plant Biology
    • /
    • v.3 no.2
    • /
    • pp.6-18
    • /
    • 1960
  • The present experiments were designed in order to clarify the differences between the long and short styled plants and the transgressive gradition in the degree of dimorphism among the three heterostylous species of the Polygonus, P. japonica, F. esculentum, and P. senticosa, based on investigations regarding the floral structure, ecological and physiological traits, the results of which are summarized as follows: (1) P. japonica, although it exhibits typical dimorphism, has undergone so high a differentiation between long and short styled that its long styled individuals behave as if they were female; and short styled individuals as if male. In long-styled individuals, filament, anther, and pollen grains show signs of degeneration, most of the pollen being abortive. On the other hand, in short styled individuals, the filament, anther, and pollen grains have attained remarkable development; the pollen grians are large and fertile. In short-plant the fertilized flowers readily drop off in every stage of their embryo development. This species has completely lost the self-fertile property, which is characteristic of the non-dimorphic Polygonum genus. Although this specsei typically exhibits the physiological characteristics of the non-dimorphic Polygonum genus. Although this specisei typically exhibits the physiological characteristics of dimorphism in controlled pollination, the short-styled individuals bear no seed in nature, thus misleading taxonomists to idenfity the short-styled plant as male. 2) The morphological feature of the flower organ of P. senticosa obviously indicates definite dimorphism. Physiologically, however, no differentiation towards dimorphism was observed, the species still retaining, both in long and short-individuals, the self-fertile property common to the Polygonum genus. Elaborate examinations revealed that regardless of the modes of pollination, both fertiization and seed setting flourish, no differentiation betwen legitimate and illegitimate unions being recognizable. This sort of physiological property has not been observed in the investigations of other heterostylous plants. It is assumed that this species is differentiated structurally into dimorphism, but not yet physiologically. In nature, however, this plant would have more opportunities to be cross-pollinated, i.e., legitimately combined, than self-pollinated because of the development of two forms of flowers. 3) In terms of heterostylism, the F. esculentum just occupies the intermediate position between P. japonica and P. senticosa structurally, ecologically, and physiologically. Doescription of some of the physiological behavior of the plant will suffice to demonstrate the above facts. While P. japonica has completely lost its self-fertile property, P. senticosa still retains it wolly. In F. esculentum 2-6% of self-fertility is the result in illegitimate combination. There occur occasionally hereditary self fertile individuals among some of the F. or 20 min. irradiation plot, when they reach any stage of the same bacterial population. In addition to this increase of total population in the plots with the more dose of UV light irradiation, it seems that the more dose of UV light irradiation is the more shortened the generation time of Azotobacter. Therefore, it is clear that variation of reproductive rate must be, mere or less, due to the genetic effects induced by UV light irradiation. On the other hand, the lag phase or logarithmic growth phase in nonirradiated culture is shortened prominently, and this must be due to the difference in bacterial number of the original inoculm. The generation time of Azotobacter is shortened by exogeneous treatment of nuclei acid derivatives, and the degree is greater in case of DNA derivatives than RNA dervatives. W.H. Price reported that the rate of ribose nucleic acid to protein in Staphylococcus muscae is proportional to the generation time: that is the faster the cell can form ribose nucleic acid, the more rapid its growth. This explains the shortening of generation time by exogeneous RNA derivatives in this work reasonably. On the other hand, it is well known that the desoxyribose nuclic acid content per cell is constant and independent of the generation time. A.D. Laren and W.N. Takahashi reported that the infectious RNA from TMV is 6 times as sensitive to inactivation by UV as it is in the form of intact virus, and that inactivation of infectious TMV involves onlu a local change on RNA chain. But, the effect of exogeneous DNA in this work suggests that irradiated living cell which cotain DNA bring about some change on DNA moleculs as well as RNA molecules. And if the mutagenic effects of UV take into consideration, it is very reasonable. Therefore, it is clear that the variation of the generation time by UV irradiation is, more or less, due to the genetic effects. Therefore, it seems that the shortness of the average lifewpan of Azotobacter by UV irradiation is resulted not only from the influence of the environmental conditions, but also from the variation of genetic factor of the individual.

  • PDF

Comparative Study of the Ablation Rates of Er: YAG Laser Irradiation on Dentin and Enamel (Er:YAG 레이저를 이용한 법랑질과 상아질의 절삭율 연구)

  • Kim, Kun-A;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.131-140
    • /
    • 2005
  • The purpose of this study was to examine the ablation rate of Er: YAG laser irradiation on dentin and enamel and to observe the microscopic structures of cavities formed after ablation of enamel and dentin in using a bur and cavities formed after ablation using laser. Er:YAG laser irradiated at 200 mJ, 250mJ, 300mJ at the frequency of 20Hz, 15Hz. The following results were obtained : 1. The ablation rate of dentin groups at power of 3 W-6 W was about $1.103{\sim}2.639mm^3/sec$ and there were no significant differences between power of 4.5 W$\sim$6 W. 2. The ablation rate of enamel groups at power of 3 W-6 W was about $0.413{\sim}0.969mm^3/sec$ and there were no significant differences between power of 4 W$\sim$6 W. 3. With SEM examination of the cavity surface treated with the conventional high speed bur revealed relatively flat appearance almost covered with a debris like smear layer. 4. With SEM examination of the lased surface of dentin groups revealed no smear layer and no debris and openings of dentinal tubules were clearly opened. But the lased surfaces of the groups over 3 W were irregular and particles were loosely attached on it. 5. With SEM examination of the lased surface of enamel groups revealed severely destructed surface at the 6 W group and melting drop materials at the 3 W group. But the lased surface of 4 W group revealed clearly ablated surface. Therefore when cutting teeth using Er:YAG laser, the lasing power which can make effective ablation rate and minimize the thermal effect could be 3W at dentin and 4W at enamel. But, further studies and additional data collection will be necessary for appropriate lasing condition of Er:YAG laser.

Literature Review on the Incidence and Risk Factor of Oral Cancer (구강암의 발생현황과 원인)

  • Han, Ji-Hyoung;Kim, Eung-Kwon;Lim, Soon-Hwan;Kim, Chang-Hee
    • Journal of dental hygiene science
    • /
    • v.12 no.5
    • /
    • pp.451-458
    • /
    • 2012
  • The purpose of this study was to examine pervasive trends in oral cancer in different countries in an effort to discuss what to do to prevent cancer and drop a death rate. The materials of the study were selected from among articles of oral cancer by searching risk factor and epidemiology at a website (www.oraloncology.com). As a result of analyzing the selected literature, it's found that in our country, the percentage of oral cancer in total cancer dropped but the number of oral cancer patients was on the rise every year. In foreign countries, the number of oral cancer patients was on the increase as well, whereas the lethality dropped. In terms of demographic characteristics, the incidence rate of oral cancer was higher among men than women overall. The incidence rate of oral cancer was larger among older people. The major causes of oral cancer were smoking and drinking. To reduce the incidence rate of oral cancer, every possible institutional, administrative and legal measure should be taken to ensure of anti-smoking policies, and publicity of moderation in and abstinence from drinking should be reinforced. The additional causes of oral cancer were demographic characteristics by country and region. The incidence of oral cancer was under the influence of that was affected when the level of personal economy and education was low. Therefore it's important to redress social imbalance within a country and among countries to remove socioeconomic divide. As the oral cancer patients has increased every year, the incidence rate of it should accurately be grasped, and sustained research efforts should be made in consideration of demographic characteristics. Early diagnosis, public oral health education and preventive policies are all required to decrease the incidence rate of oral cancer.

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Appearance Rates of Several Substances into Cerebrospinal Fluid of Histamine-treated Rabbits (히스타민 투여시 토끼 뇌척수액으로의 물질 출현율)

  • Kim, Won-Shik;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.21-31
    • /
    • 1968
  • The appearance rates of antipyrine and urea into cerebrospinal fluid from blood were studied in the rabbits which were in the state of hypotension and of high permeability in the capillary beds following injection of histamine. The alteration in the distribution of electrolytes among various compartments of the brain and the permeability characteristics in the blood-cerebrospinal fluid barrier were also observed. Adult male rabbits, weighing around 2 kg, were used. Twenty four rabbits were divided into 3 groups. Besides the control group, histamine treated rabbits were categorized into 2 groups. $H_1$ consisted of the rabbits showing moderate responses to histamine and ranging from 62 to 80 mmHg in their mean anterial blood pressure. The animals which belong to $H_2-group$ showed severe responses to histamine and the mean anterial blood pressures dropped to 30-50 mmHg. Animals were anesthetized with nembutal, 30mg/kg i.v. The mean arterial blood pressure was read by means of the mercury manometer connected to the femoral artery. The animals, treated with histamine, were kept in hypotensive state at least for 40 minutes before the administration of the test-substances. The test-substances, 300 mg of urea and 200 mg of antipyrine, were dissolved in 3 ml of distilled water and were injected into the ear vein of the rabbit. After 10 minutes elapsed arterial blood sample was taken from the femoral artery and cerebrospinal fluid from the cisterna magna. Brain tissues were also analysed with respect to electrolytes in order to observe the disturbances in the electrolytes balance as well as in the function of the central nervous system. The results obtained were as follow: 1. The ratio of antipyrine concentration in cerebrospinal fluid to that of arterial blood plasma, that was the distribution ratio, was close to unity, revealing a well established equilibrium between the compartments of blood and cerebrospinal fluid in 10 minutes. In other words, there was no diffusion barrier with regard to antipyrine. The ratios over unity which were frequently seen in the histamine treated animals were attributable to the early penetration of the substance into the cerebrospinal fluid. 2. The appearance rates of urea into the cerebrospinal fluid in the histamine treated rabbits were higher in comparison with those of in the control animals. The increasing tendency in the rates was particularly remarkable in the $H_2-group$, showing the enhanced penetration of urea across the boondary. 3. In the htisamine treated $H_2-group$ the concentration of potassium in the blood plasma and cerebrospinal fluid well exceeded the control values and showed 8.5 and 9.0 mEq/l in average, respectively. Simultaneous drops in the brain tissue water were noticed, suggesting the leakage of intracellular potassium. 4. There was a coincidence in the rising pattern of potassium in the blood plasma and in the cerebrospinal fluid of $H_2-group$ and at least partial removal of the blood-cerebrospinal fluid barrier with respect to potassium was suggested in these animals. 5. The concentration of sodium in the blood plasma or in the cerebrospinal fluid showed no significant changes following histamine injection. However, sodium in the brain tissue revealed slight elevation in the histamine treated groups. 6. The ratios of the concentrations of potassium to those of sodium, [K]/[Na] in the brain tissues, were 1.92 in the control 1.82 in the $H_1$ and 1.52 in the $H_2-group$, respectively. The marked drop in the $H_2-group$ might represent neural dysfunction in the extremely hypotensive rabbits.

  • PDF

Effect of Exercise on Blood Concentrations of Ethanol, Lactate and Glucose in Men Showing Facial Flush after Ethanol Ingestion (음주후(飮酒後) 얼굴 붉어지는 사람에 있어서 운동(運動)이 혈중(血中) 에타놀, 유산(乳酸) 및 포도당(葡萄糖) 농도(濃度)에 미치는 효과(效果))

  • Cho, Young-Ho;Kim, Hyeong-Jin;Lee, Won-Jung;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.65-77
    • /
    • 1986
  • To elucidate the effect of exercise on blood concentrations of ethanol, lactate and glucose in men who show facial flush after ethanol ingestion, 59 healthy male college students were studied. After 6 or more hours of fasting, the subjects were administered 3 ml of 25% ethanol solution(Soju) per liter of total body water. For control experiment Soju was replaced with the same dose of water. Exercise performed was vertical jumping on a rebounder for 3 min immediately after drinking. The subjects were classified into 6 groups: water ingestion(W), flushed (F) and non-flushed (N) groups after ethanol ingestion, water ingestion and exercise(WE), flushed(FE) and non-flushed (NE) groups after ethanol ingestion and exercise. Blood ethanol concentration in the exercise groups(NE, FE) was lower until 60 min after drinking than that in the non-exercise groups(N,F). Factor k representing the rate of ethanol absorption was markedly lower in the exercise groups than in the non-exercise groups. The flushed groups(F,FE) showed higher blood ethanol level than the non-flushed groups (N,NE) from 30 to 120 min after drinking. Blood lactate concentration in WE group was elevated immediately after exercise and returned to the resting level at 60 min after exercise. Ethanol increased blood lactate level from 30 to 120 min after ethanol drinking, Exercise after ethanol ingestion produced a sharp increase and then drop in blood lactate level which was stilled significantly higher than the resting level all the way through 120 min. Blood glucose concentration was decreased at 15 min after exercise. Ethanol-administered groups except F group showed a steady decrease in blood glucose level from 30 through 120 min. Heart rate was elevated by ethanol only in the flushed groups. Heart rate in F group was significantly increased at 4 min after ethanol and was maintained at high level until 120 min. In WE and NE groups, heart rate was significantly increased immediately after exercise and returned to the resting level at 60 min. The FE group, however, showed a consistently elevated heart rate throughout the 120-min experimental period. Taken together, the exercise alone produced a delayed ethanol absorption, a prompt increase in heart rate and blood lactate level and a decrease in blood glucose level early in the recovery period from exercise. After ethanol administration, blood lactate was elevated and blood glucose was lowered from 30 to 120 min. Flushed subjects showed rapid increase in heart rate after ethanol drinking and higher blood ethanol level than non-flushed ones from 30 to 120 min after drinking.

  • PDF

A Study on the Manual Skills of Experimental Apparatuses of Preservice Elementary School Teachers (초등 예비교사의 실험 기구 조작 능력에 대한 연구)

  • Lee, So-Ree;Choi, Hyun-Dong;Lim, Jae-Keun;Shin, Se-Young;Yang, Il-Ho
    • Journal of Science Education
    • /
    • v.35 no.1
    • /
    • pp.80-90
    • /
    • 2011
  • The purpose of this study is to investigate manual skills of experimental apparatuses of pre-service elementary school teachers by examining and analyzing the process of experiments conducted by pre-teachers. For this study, 24 pre-service elementary school teachers were selected as the subjects and 4 experimental apparatuses were chosen through analyzing science textbooks from 3rd grade to 6th grade in elementary school. The selected experimental apparatuses were alcohol burner, dropper, microscope, instruments for making a prepared specimen. In addition, a task was carefully chosen to conduct an investigation in real settings and a series of evaluation standards was developed. While 3 subjects conducted experiments in separated and independent space at the same time, 3 collaborators observed the experiment process and recorded whether the subject met the evaluation standards or not, using O, X. The study suggests that pre-service elementary school teachers' manual skills of experimental apparatuses were under far below our projections. Particularly, in case of alcohol burner, the subjects showed lower ability to properly light the burners - which is to brush through the lampwick with fire - and to adjust the height of tripods according to the flame. Also, when it comes to dropper, they were not held the way they were supposed to be. In addition, when designing prepared specimen, the subjects used their hands instead of tweezers and often skipped the process of dripping water drop and wiping water with an oilpaper. Moreover, they did not know how to use a microscope properly so there were many times that they could not focus a microscope, failing to observe the objects. Educational implications are discussed.

  • PDF

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.