• Title/Summary/Keyword: DR6

Search Result 717, Processing Time 0.027 seconds

An Experimental Study on Body Temperature Differ Differences Taken in Different Areas in the Mouth - Comparison of Body Temperature between Right and Left Subligual Areas According to Time Intervals - (체온계투입 부위에 따른 구강체온 차이에 관한 실험적 연구)

  • 임난영
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.1
    • /
    • pp.63-72
    • /
    • 1977
  • The Purposes of this study are to determine differences of body temperature between Right arid left subligual areas itself and differences depending upon the utilization rate of mastication according to time intervals and to determine the length of time necessary for temperature taking. This Experiment was conducted from Oct 6 through Oct 11, 1975. in which accurately tested clinical Centigrade Thermometers have been utilized. Two thermometers were inserted simultaneously under the right and left sublingual areas and the mouth kept closed while thermometers were in Place. Temperature readings were dr no at three minutes, five minutes and ten minutes. These procedures were repeated one hundred times to different subjects and the data were analyzed statistically by means of the t-test and the F-ratio. Under the 10 hypotheses designed for this study, The findings obtained are as follows; 1. The body temperatures taken at 3, 5, 10minutes intervals in the left sublingual areas were significantly higher than in the right sublingual areas , The average differences of body temperature between the right and left sublingual areas were 0.09$^{\circ}C$, 0.05$^{\circ}C$ and 0.03$^{\circ}C$ in the oder of time interval of 3, 5, and 10 minutes. 2. The body temperatures taken in the right sublingual areas among three different temperature readings, 3, 5 and 10 minutes were significantly different in 57 subjects who have been utilizing evenly both sides of the Teeth. The average readings in a group taking for 3 minutes was 37.04$^{\circ}C$, for 5 minutes 37.15$^{\circ}C$ and for 10minutes 37.28$^{\circ}C$. 3. The body temperatures taken in the left sublingual areas among three different temperature readings, 3, 5 and 10 minutes were significantly different in 57 subjects who have been utilizing evenly both sides of the tenth. The average reading in a group taking for 3 minutes was 37.13$^{\circ}C$, for 5 minutes 37.2$^{\circ}C$ and for 10 minutes 37.31$^{\circ}C$. 4., Oral temperatures taken at 3, 5, 10 minutes intervals at the side of mouth utilized for more frequent mastication were Significantly higher than the other side. The average differences of body temperature between more frequently utilized side and Less frequently utilized side were 0.08f, 0.08f and 0.09f in the order of time interval of 3, 5 and 10 minutes. 5. Oral temperature taken at the side of mouth more frequently utilized for mastication among three different temperature readings, 3, 5 and 10 minutes were significantly different in 43 subjects who have been unequally utilizing either side of teeth. The average reading in a group taking for 3 minutes was 37.09$^{\circ}C$, for 5 minutes 37.17$^{\circ}C$ and for 10 minutes 37.3$^{\circ}C$. 6. Oral temperature taken at the side of mouth less frequently utilized for mastication among three different temperature readings 3, 5 and 10 minutes were significantly different in 43 subjects who have been unequally utilizing either side of teeth. The average reading in a group taking for 3 minutes was 37.01$^{\circ}C$, for S minutes 37.09$^{\circ}C$ and for minutes 37.21$^{\circ}C$. As a result of this study, these differences among time intervals were statistically significant, but there were not so much differences as to be considered important in the clinical practice. Therefore, there would be clinically little difference between two groups who are taking for 3 minutes and for 10 minutes.

  • PDF

Validation and Calibration of Semi-Quantitative Food Frequency Questionnaire - With Participants of the Korean Health and Genome Study - (반정량식품섭취빈도조사지의 타당성 검증 및 보정 - 지역사회 유전체 코호트 참여자를 대상으로 -)

  • Ahn, Youn-Jhin;Lee, Ji-Eun;Cho, Nam-Han;Shin, Chol;Park, Chan;Oh, Berm-Seok;Kimm, Ku-Chan
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.2
    • /
    • pp.173-182
    • /
    • 2004
  • We carried out a validation-calibration study of the food frequency questionnaire (FFQ) that we had previously developed for a community-based cohort of the Korean Genome and Health Study of the Korea National Genome Research Institute. We have collected a total of 254 3-day diet records (DRs) from 400 subjects, 200 each randomly selected from the two study cohorts of Ansung and Ansan. FFQ was administered at the time of cohort recruitment in 2001, and DRs were collected during a two month period from January through February of 2002. The mean age was 52.2 years. Farming for men and housewife for women were the most common occupations. The majority of the subjects had undergone 6∼12 years of education. The general characteristics including demographic and other data were not different from the total cohort subjects. Absolute levels of consumed nutrients including total energy (energy), protein, fat, carbohydrate, calcium, phosphorus, sodium, potassium, iron, retinol, carotene, vitamin A, thiamin, riboflavin, niacin and vitamin C were compared. The average of energy intake was not significantly different between the data collected by the 2 methods. However, consumptions of protein and fat were higher in data of DRs, whereas that of carbohydrate was higher in FFQ data. Significant correlation of each nutrient consumption between the data sets was observed (p < 0.05) except in the case of iron, while the average correlation coefficient between them was 0.22 ranging from 0.33 for energy to 0.11 for iron. The results of cross classification by quantile for exact classification ranged from 25.2% (carotene) to 35.0% (phosphorus), and from 64.6% (vitamin A) to 76.4% (retinol) for adjacent classification. The proportion of completely opposite classification was 8.1% in average. Calibration slope was estimated by regression and calibration parameters ranged from 0.025 for carotene to 0.423 for niacin. We conclude that the FFQ we have developed is an appropriate tool for assessing the nutrient intakes as ranking exposures in epidemiology studies in view that amounts of consumed nutrients obtained by FFQ were similar to those collected by DRs, that correlations between consumed nutrients collected by these methods were significant, and that classification results were relatively fair. The correlation coefficients, however, were lower than expected, which may be mainly due to the survey season. In fact, any short-term dietary survey cannot accurately reflect the overall dietary intakes that change heavily depending on seasons. Further studies including the analysis of chemical indices would be helpful for the studies of causal relationship between the diet and disease.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Why A Multimedia Approach to English Education\ulcorner

  • Keem, Sung-uk
    • Proceedings of the KSPS conference
    • /
    • 1997.07a
    • /
    • pp.176-178
    • /
    • 1997
  • To make a long story short I made up my mind to experiment with a multimedia approach to my classroom presentations two years ago because my ways of giving instructions bored the pants off me as well as my students. My favorite ways used to be sometimes referred to as classical or traditional ones, heavily dependent on the three elements: teacher's mouth, books, and chalk. Some call it the 'MBC method'. To top it off, I tried audio-visuals such as tape recorders, cassette players, VTR, pictures, and you name it, that could help improve my teaching method. And yet I have been unhappy about the results by a trial and error approach. I was determined to look for a better way that would ensure my satisfaction in the first place. What really turned me on was a multimedia CD ROM title, ELLIS (English Language Learning Instructional Systems) developed by Dr. Frank Otto. This is an integrated system of learning English based on advanced computer technology. Inspired by the utility and potential of such a multimedia system for regular classroom or lab instructions, I designed a simple but practical multimedia language learning laboratory in 1994 for the first time in Korea(perhaps for the first time in the world). It was high time that the conventional type of language laboratory(audio-passive) at Hahnnam be replaced because of wear and tear. Prior to this development, in 1991, I put a first CALL(Computer Assisted Language Learning) laboratory equipped with 35 personal computers(286), where students were encouraged to practise English typing, word processing and study English grammar, English vocabulary, and English composition. The first multimedia language learning laboratory was composed of 1) a multimedia personal computer(486DX2 then, now 586), 2) VGA multipliers that enable simultaneous viewing of the screen at control of the instructor, 3) an amplifIer, 4) loud speakers, 5)student monitors, 6) student tables to seat three students(a monitor for two students is more realistic, though), 7) student chairs, 8) an instructor table, and 9) cables. It was augmented later with an Internet hookup. The beauty of this type of multimedia language learning laboratory is the economy of furnishing and maintaining it. There is no need of darkening the facilities, which is a must when an LCD/beam projector is preferred in the laboratory. It is headset free, which proved to make students exasperated when worn more than- twenty minutes. In the previous semester I taught three different subjects: Freshman English Lab, English Phonetics, and Listening Comprehension Intermediate. I used CD ROM titles like ELLIS, Master Pronunciation, English Tripple Play Plus, English Arcade, Living Books, Q-Steps, English Discoveries, Compton's Encyclopedia. On the other hand, I managed to put all teaching materials into PowerPoint, where letters, photo, graphic, animation, audio, and video files are orderly stored in terms of slides. It takes time for me to prepare my teaching materials via PowerPoint, but it is a wonderful tool for the sake of presentations. And it is worth trying as long as I can entertain my students in such a way. Once everything is put into the computer, I feel relaxed and a bit excited watching my students enjoy my presentations. It appears to be great fun for students because they have never experienced this type of instruction. This is how I freed myself from having to manipulate a cassette tape player, VTR, and write on the board. The student monitors in front of them seem to help them concentrate on what they see, combined with what they hear. All I have to do is to simply click a mouse to give presentations and explanations, when necessary. I use a remote mouse, which prevents me from sitting at the instructor table. Instead, I can walk around in the room and enjoy freer interactions with students. Using this instrument, I can also have my students participate in the presentation. In particular, I invite my students to manipulate the computer using the remote mouse from the student's seat not from the instructor's seat. Every student appears to be fascinated with my multimedia approach to English teaching because of its unique nature as a new teaching tool as we face the 21st century. They all agree that the multimedia way is an interesting and fascinating way of learning to satisfy their needs. Above all, it helps lighten their drudgery in the classroom. They feel other subjects taught by other teachers should be treated in the same fashion. A multimedia approach to education is impossible without the advent of hi-tech computers, of which multi functions are integrated into a unified system, i.e., a personal computer. If you have computer-phobia, make quick friends with it; the sooner, the better. It can be a wonderful assistant to you. It is the Internet that I pay close attention to in conjunction with the multimedia approach to English education. Via e-mail system, I encourage my students to write to me in English. I encourage them to enjoy chatting with people all over the world. I also encourage them to visit the sites where they offer study courses in English conversation, vocabulary, idiomatic expressions, reading, and writing. I help them search any subject they want to via World Wide Web. Some day in the near future it will be the hub of learning for everybody. It will eventually free students from books, teachers, libraries, classrooms, and boredom. I will keep exploring better ways to give satisfying instructions to my students who deserve my entertainment.

  • PDF

An Immune-Electron Microscopic Study for Cluster Designation on the Phagocytic Synovial Cells in the Knee Joint of the Human (인체 무릎관절 윤활포식세포 cluster designation 표지에 관한 면역전자현미경적 연구)

  • Lim, Hyoung-Soo;Cho, Kook-Hyeung;Kim, Yong-Wook;Park, Kyeong-Han;Hwang, Young-Il;Chang, Ka-Young;Hwang, Douk-Ho
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.173-183
    • /
    • 2000
  • This study was designed to observe the ultrastructural localization of synoviocytes, which are concerned with the function of phagocytic synovial cells (type A synoviocytes, macrophage-like synoviocytes), in the knee joint of the human for CD14 and CD105 by cryo-immune-electron microscopic technique. The synovium were dissected and fixed for two hours (in 4% paraformaldehyde and 0.1% glutaraldehyde mixture), and were immerged in 2.3 M sucrose and 20% PVP solution. Finally, they were cut with the cryoultramicrotome and labelled with primary antibodies (monoclonal mouse anti-human CD14, monoclonal mouse anti-human CD105 (endoglin) and secondary (donkey anti-mouse IgG) tagged with 6 nm colloidal gold particles. The tissues were observed under transmission electron microscope. This study was resulted as follows. 1. In the synovium of the human knee joint, CD14+ cells were identified. These cells showed phagocytic synovial cell's features. In the phagocytic synoviocyte, the distributions of CD14 were marked in the cytoplasm, around vacuoles, and in cytoplasmic process, but not detected inside of vacuoles. 2. In the synovium of the human knee joint, CD105+ cells were identified. These cells were recognized endothelial cells and phagocytic synovial cells. In the phagocytic synovial cells, the distributions of CD105 (endoglin) were marked in cytoplasic process, around vacuoles, and in cell membrane, but not detected inside of vacuoles. On the basis of above findings, it is obvious that phagocytic synovial cells were marked at CD 14 and CD 105, and might be play the role of activated macrophages or phagocytes in the synovial membrane.

  • PDF

Mammalian Cloning by Nuclear transfer, Stem Cell, and Enzyme Telomerase (핵치환에 의한 cloning, stem cell, 그리고 효소 telomerase)

  • 한창열
    • Korean Journal of Plant Tissue Culture
    • /
    • v.27 no.6
    • /
    • pp.423-428
    • /
    • 2000
  • In 1997 when cloned sheep Dolly and soon after Polly were born, it had become head-line news because in the former the nucleus that gave rise to the lamb came from cells of six-year-old adult sheep and in the latter case a foreign gene was inserted into the donor nucleus to make the cloned sheep produce human protein, factor IX, in e milk. In the last few years, once the realm of science fiction, cloned mammals especially in livestock have become almost commonplace. What the press accounts often fail to convey, however, is that behind every success lie hundreds of failures. Many of the nuclear-transferred egg cells fail to undergo normal cell divisions. Even when an embryo does successfully implant in the womb, pregnancy often ends in miscarriage. A significant fraction of the animals that are born die shortly after birth and some of those that survived have serious developmental abnormalities. Efficiency remains at less than one % out of some hundred attempts to clone an animal. These facts show that something is fundamentally wrong and enormous hurdles must be overcome before cloning becomes practical. Cloning researchers now tent to put aside their effort to create live animals in order to probe the fundamental questions on cell biology including stem cells, the questions of whether the hereditary material in the nucleus of each cell remains intact throughout development, and how transferred nucleus is reprogrammed exactly like the zygotic nucleus. Stem cells are defined as those cells which can divide to produce a daughter cell like themselves (self-renewal) as well as a daughter cell that will give rise to specific differentiated cells (cell-differentiation). Multicellular organisms are formed from a single totipotent stem cell commonly called fertilized egg or zygote. As this cell and its progeny undergo cell divisions the potency of the stem cells in each tissue and organ become gradually restricted in the order of totipotent, pluripotent, and multipotent. The differentiation potential of multipotent stem cells in each tissue has been thought to be limited to cell lineages present in the organ from which they were derived. Recent studies, however, revealed that multipotent stem cells derived from adult tissues have much wider differentiation potential than was previously thought. These cells can differentiate into developmentally unrelated cell types, such as nerve stem cell into blood cells or muscle stem cell into brain cells. Neural stem cells isolated from the adult forebrain were recently shown to be capable of repopulating the hematopoietic system and produce blood cells in irradiated condition. In plants although the term$\boxDr$ stem cell$\boxUl$is not used, some cells in the second layer of tunica at the apical meristem of shoot, some nucellar cells surrounding the embryo sac, and initial cells of adventive buds are considered to be equivalent to the totipotent stem cells of mammals. The telomere ends of linear eukaryotic chromosomes cannot be replicated because the RNA primer at the end of a completed lagging strand cannot be replaced with DNA, causing 5' end gap. A chromosome would be shortened by the length of RNA primer with every cycle of DNA replication and cell division. Essential genes located near the ends of chromosomes would inevitably be deleted by end-shortening, thereby killing the descendants of the original cells. Telomeric DNA has an unusual sequence consisting of up to 1,000 or more tandem repeat of a simple sequence. For example, chromosome of mammal including human has the repeating telomeric sequence of TTAGGG and that of higher plant is TTTAGGG. This non-genic tandem repeat prevents the death of cell despite the continued shortening of chromosome length. In contrast with the somatic cells germ line cells have the mechanism to fill-up the 5' end gap of telomere, thus maintaining the original length of chromosome. Cem line cells exhibit active enzyme telomerase which functions to maintain the stable length of telomere. Some of the cloned animals are reported prematurely getting old. It has to be ascertained whether the multipotent stem cells in the tissues of adult mammals have the original telomeres or shortened telomeres.

  • PDF

DEVELOPMENT OF SAFETY-BASED LEVEL-OF-SERVICE CRITERIA FOR ISOLATED SIGNALIZED INTERSECTIONS (독립신호 교차로에서의 교통안전을 위한 서비스수준 결정방법의 개발)

  • Dr. Tae-Jun Ha
    • Proceedings of the KOR-KST Conference
    • /
    • 1995.02a
    • /
    • pp.3-32
    • /
    • 1995
  • The Highway Capacity Manual specifies procedures for evaluating intersection performance in terms of delay per vehicle. What is lacking in the current methodology is a comparable quantitative procedure for ass~ssing the safety-based level of service provided to motorists. The objective of the research described herein was to develop a computational procedure for evaluating the safety-based level of service of signalized intersections based on the relative hazard of alternative intersection designs and signal timing plans. Conflict opportunity models were developed for those crossing, diverging, and stopping maneuvers which are associated with left-turn and rear-end accidents. Safety¬based level-of-service criteria were then developed based on the distribution of conflict opportunities computed from the developed models. A case study evaluation of the level of service analysis methodology revealed that the developed safety-based criteria were not as sensitive to changes in prevailing traffic, roadway, and signal timing conditions as the traditional delay-based measure. However, the methodology did permit a quantitative assessment of the trade-off between delay reduction and safety improvement. The Highway Capacity Manual (HCM) specifies procedures for evaluating intersection performance in terms of a wide variety of prevailing conditions such as traffic composition, intersection geometry, traffic volumes, and signal timing (1). At the present time, however, performance is only measured in terms of delay per vehicle. This is a parameter which is widely accepted as a meaningful and useful indicator of the efficiency with which an intersection is serving traffic needs. What is lacking in the current methodology is a comparable quantitative procedure for assessing the safety-based level of service provided to motorists. For example, it is well¬known that the change from permissive to protected left-turn phasing can reduce left-turn accident frequency. However, the HCM only permits a quantitative assessment of the impact of this alternative phasing arrangement on vehicle delay. It is left to the engineer or planner to subjectively judge the level of safety benefits, and to evaluate the trade-off between the efficiency and safety consequences of the alternative phasing plans. Numerous examples of other geometric design and signal timing improvements could also be given. At present, the principal methods available to the practitioner for evaluating the relative safety at signalized intersections are: a) the application of engineering judgement, b) accident analyses, and c) traffic conflicts analysis. Reliance on engineering judgement has obvious limitations, especially when placed in the context of the elaborate HCM procedures for calculating delay. Accident analyses generally require some type of before-after comparison, either for the case study intersection or for a large set of similar intersections. In e.ither situation, there are problems associated with compensating for regression-to-the-mean phenomena (2), as well as obtaining an adequate sample size. Research has also pointed to potential bias caused by the way in which exposure to accidents is measured (3, 4). Because of the problems associated with traditional accident analyses, some have promoted the use of tqe traffic conflicts technique (5). However, this procedure also has shortcomings in that it.requires extensive field data collection and trained observers to identify the different types of conflicts occurring in the field. The objective of the research described herein was to develop a computational procedure for evaluating the safety-based level of service of signalized intersections that would be compatible and consistent with that presently found in the HCM for evaluating efficiency-based level of service as measured by delay per vehicle (6). The intent was not to develop a new set of accident prediction models, but to design a methodology to quantitatively predict the relative hazard of alternative intersection designs and signal timing plans.

  • PDF

A STUDY ON NEWCASTLE DISEASE VACCINATION: The Immunological Response to Inactivated and Attenuated Virus Vaccines (Newcastle병(病)의 예방접종(豫防接種)에 관한 연구(硏究); 사독(死毒)백신 및 감독(減毒)된 생독(生毒)백신에 대한 면역학적(免疫學的) 반응(反應))

  • Chung, Gill Taik
    • Korean Journal of Veterinary Research
    • /
    • v.2 no.1
    • /
    • pp.27-36
    • /
    • 1962
  • Immune response to two methods of Newcastle disease virus vaccine, one inactivated and the other attenuated was observed and the data presented. (1) Administration of inactivated virus vaccine in an amount of 1.0 ml. by intramuscular route gave an appreciable immunity to Newcastle disease for a period of at least three-and-half months. (2) The chickens given attenuated virus vaccine in the drinking water produced satisfactory immunity as manifested by the fact that immunized birds showed resistance when challenged 105 days after the vaccination and maintained high degree of HI titer for a period of 75 days. (3) Vaccination with the attenuated virus vaccine in drinking water is very simple and time saving in procedure, although the duration of immunity seems to be slightly shorter than that proced by inactivated virus vaccine. The author wishes to express his appreciation, to Drs. Kyu Myung Lee, Chang Koo Lee, and Ryong Sook Kee of their suggestions and help. The author is also indebted to Dr. Chang Hi Lee, Director of Anyang Veterinary Laboratory, who allowed the use of the facilities of the laboratory, whitout which this experiment could not have been undertaken.

  • PDF