• Title/Summary/Keyword: DR4

Search Result 1,182, Processing Time 0.028 seconds

Chronic Low-Dose Nonylphenol or Di-(2-ethylhexyl) Phthalate has a Different Estrogen-like Response in Mouse Uterus

  • Kim, Juhye;Cha, Sunyeong;Lee, Min Young;Hwang, Yeon Jeong;Yang, Eunhyeok;Ryou, Chongsuk;Jung, Hyo-Il;Cheon, Yong-Pil
    • Development and Reproduction
    • /
    • v.22 no.4
    • /
    • pp.379-391
    • /
    • 2018
  • Through the development of organic synthetic skill, chemicals that mimic signaling mediators such as steroid hormones have been exposed to the environment. Recently, it has become apparent that this circumstance should be further studied in the field of physiology. Estrogenic action of chronic low-dose nonylphenol (NP) and di-(2-ethylhexyl) phthalate (DEHP) in mouse uterus was assessed in this study. Ten to twelve-week-old female mice (CD-1) were fed drinking water containing NP (50 or $500{\mu}g/L$) or DEHP (133 or $1,330{\mu}g/L$) for 10 weeks. Uterine diameter, the thickness of myometrium and endometrium, and the height of luminal epithelial cells were measured and the number of glands were counted. The expression levels of the known $17{\beta}$-estradiol ($E_2$)-regulated genes were evaluated with real-time RT-PCR methodology. The ration of uterine weight to body weight increased in $133{\mu}g/L$ DEHP. Endometrial and myometrial thickness increased in 133 and $1,330{\mu}g/L$ DEHP treated groups, and in 50, $500{\mu}g/L$ NP and $133{\mu}g/L$ DEHP, respectively. The height of luminal epithelial cell decreased in NP groups. The numbers of luminal epithelial gland were decreased in NP groups but increased in $50{\mu}g/L$ DEHP group. The histological characters of glands were not different between groups. The mRNA expression profiles of the known $17{\beta}$-estradiol ($E_2$) downstream genes, Esr1, Esr2, Pgr, Lox, and Muc1, were also different between NP and DEHP groups. The expression levels dramatically increased in some genes by the NP or DEHP. Based on these results, it is suggested that the chronic low-dose NP or DEHP works as estrogen-like messengers in uterus with their own specific gene expression-regulation patterns.

The Comparative Study on the Efficiency of Kunsan Port (군산항만의 효율성 비교연구)

  • Nah, Ho-Soo;Kim, Hyun-Cho
    • Journal of Korea Port Economic Association
    • /
    • v.25 no.2
    • /
    • pp.277-300
    • /
    • 2009
  • By using data envelopment analysis(DEA) this research measures the efficiency of Korea's seven middle-sized seaports and their Malmquist productivity from 1998 to 2007. Under the assumption of CRS(constant returns to scale) and VRS(variable returns to scale), seaports' ranking of efficiency are measured. Kunsan Port is confirmed as a middle-performed port in the various measurements. Important finding facts are as follows. 1)Kunsan Port has the efficiency level from 53% to 57% of efficient ports' level under the assumption of CRS and VRS. 2)In terms of average efficiency level, the gap among these 7 seports' efficiency levels has been widened during the period from 1998 to 2007. 3)Kunsan Port has shown the characteristics of DRS more frequently in terms of returns to scale. 4) Kunsan Port's average total factor productivity has been lower at the rate of 0.7% during the period from 1998 to 2007. 5)Kunsan Port has shown technical progress at the rate of 3.1% in this period. In future research the more and better data will be expected to improve the understanding of Korean seaports' efficiency characteristics.

  • PDF

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

Anti-inflammatory Effects of Earthing Mattress in Mouse (Balb/c 생쥐에 대한 어싱 매트리스에 의한 항염 효과)

  • Kim, Ji Youn
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.89-93
    • /
    • 2022
  • Earthing, caused by direct skin contact with the Earth's surface, is used to reduce the symptoms of inflammation (fever, fever, swelling and pain). However, there is little evidence to support the anti-inflammatory effects of earthing mattresses. Therefore, this study was conducted to investigate whether anti-inflammatory effect of earthing mattress using an in vivo animal model. The anti - inflammatory effect was evaluated by measuring ear thickness and foot volume in 12-O-tetradecanoylphorbol-13 acetate (TPA) - induced ear edema and carrageenan - induced paw edema model, respectively. Balb/c mouse in carrageenan paw edema model showed significant anti - inflammatory effect in the group treated with earthing mattress for 4 hours or 24 hours for 3 days. For females, the anti-inflammatory effect was greater when the earthing mattress was added to the mattress than the mattress alone treatment. From the above results, it was found that the female responds more to the effect of the earthing as well as the mattress effect. In addition, when the male and female Balb/c mice were exposed to mattresses and earthing mattresses for 24 h for 3 days, respectively, the mattress and earthing mattresses showed significant inhibition of IL (Interleukin)-1β levels compared to the control. In the TPA ear edema model, Balb/c mouse showed significant anti - inflammatory effect in the group treated with the earthing mattress for 4 hours or 24 hours for 3 days. Both males and females showed more anti-inflammatory effects when they were exposed to earthing mattresses with mattresses added to the mattresses. From the above results, it was found that both male and female respond to the effect of earthing as well as the mattress effect in the TPA ear edema model. In conclusion, in this study, we have verified that earthing mattress shows inhibitory effects on TPA and carrageenan-induced inflammation. From these results, it is suggested that the anti-inflammatory effect can be expected by applying the earthing mattress to patients suffering from inflammatory diseases. However, there is a need to pinpoint exactly how the earthing mattress relieves inflammation, and further research is needed to investigate the mechanism.

Systematic Review of the Effects of Blood Flow Exercise for Health-care Promotion: A Focus on Korean Domestic Research (헬스케어 증진을 위한 혈류조절 가압 운동의 효과에 대한 체계적 문헌고찰 ; 국내 연구 중심으로)

  • Seo, Tae-Hwa;Kim, Dong-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.447-454
    • /
    • 2020
  • The purpose of this study was to determine the clinical effects of blood flow regulation exercise for improving patients' health care and its usefulness as a rehabilitation model for various diseases by analyzing and examining the existing literature. A literature review of Korean academic journals published over a 10-year period, from 2010 to 2019, was conducted using words such as "blood flow regulation," "blood flow restriction," "low-intensity exercise," and "Kaatsu." Kaatsu is a blood flow regulation exercise developed in 1966 by Dr. Yoshiaki Sato of Japan. It is an efficient and effective exercise method that uses blood flow regulation bands that increase the secretion of growth hormones to develop muscles within a short time, improves blood circulation and metabolism to prevent and improve adult diseases, shortens the rehabilitation period, and improves cardiovascular function. The study participants consisted of 10 patients, of whom four were elderly, four had obesity, one was a stroke patient, and one was a trauma patient. The results of this study show that the blood flow regulation exercise, which is a low-intensity exercise, has the same effect as high-intensity exercise, which supports the evidence that it is a highly efficient exercise method for muscle development and rehabilitation of the elderly, adolescents, and patients with injuries who have difficulty in general exercising. For future studies, further reviews are necessary to verify the effectiveness of the exercise method according to blood flow regulation site and type of disease.

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

Medium and Long-Term Data from a Series of 96 Endoscopic Transsphenoidal Surgeries for Cushing Disease

  • Buruc Erkan;Muhammed Bayindir;Ebubekir Akpinar;Osman Tanriverdi;Ozan Hasimoglu;Lutfi Sinasi Postalci;Didem Acarer Bugun;Dilara Tekin;Sema Ciftci;Ilkay Cakir;Meral Mert;Omur Gunaldi;Esra Hatipoglu
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.2
    • /
    • pp.237-248
    • /
    • 2024
  • Objective : Postoperative data on Cushing's disease (CD) are equivocal in the literature. These discrepancies may be attributed to different series with different criteria for remission and variable follow-up durations. Additional data from experienced centers may address these discrepancies. In this study, we present the results obtained from 96 endoscopic transsphenoidal surgeries (ETSSs) for CD conducted in a well-experienced center. Methods : Pre- and postoperative data of 96 ETSS in 87 patients with CD were included. All cases were handled by the same neurosurgical team between 2014 and 2022. We obtained data on remission status 3-6 months postoperatively (medium-term) and during the latest follow-up (long-term). Additionally, magnetic resonance imaging (MRI) and pathology results were obtained for each case. Results : The mean follow-up duration was 39.5±3.2 months. Medium and long-term remission rates were 77% and 82%, respectively. When only first-time operations were considered, the medium- and long-term remission rates were 78% and 82%, respectively. The recurrence rate in this series was 2.5%. Patients who showed remission between 3-6 months had higher long-term remission rates than did those without initial remission. Tumors >2 cm and extended tumor invasion of the cavernous sinus (Knosp 4) were associated with lower postoperative remission rates. Conclusion : Adenoma size and the presence/absence of cavernous sinus invasion on preopera-tive MRI may predict long-term postoperative remission. A tumor size of 2 cm may be a supporting criterion for predicting remission in Knosp 4 tumors. Further studies with larger patient populations are necessary to support this finding.

Analysis of the Efficiency of Entrepreneurship Support in Korean Universities (국내 대학의 창업지원 효율성 분석)

  • Heung-Hee Kim;Dae-Geun Kim
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.19 no.4
    • /
    • pp.87-101
    • /
    • 2024
  • This study aims to provide insights for the efficient utilization of resources by analyzing the entrepreneurship support efficiency of Korean universities. To identify the factors influencing the number of entrepreneurs, which is the primary goal of university entrepreneurship support, a multiple regression analysis was conducted, identifying five effective independent variables. Using these five identified independent variables as input variables and the number of entrepreneurs as the output variable, the DEA method was used to analyze the efficiency of entrepreneurship support for each university as of 2023. The analysis of 150 four-year universities in Korea showed that nine universities exhibited complete efficiency in both CCR and BCC models. Among the remaining 141 universities that showed inefficiency, the cause was scale for five universities, technology for two universities, and both scale and technology for 134 universities. Regarding the returns to scale, nine universities exhibited CRS, 79 exhibited IRS, and 62 exhibited DRS. Additionally, reference groups that could serve as benchmarks for improving the efficiency of inefficient universities were identified, and target values(projections) for each variable to achieve efficiency were also presented. Despite the limitations of the DEA model, this study helps each university identify the causes of inefficiency in their entrepreneurship support and derive specific improvements to enhance efficiency. This facilitates more efficient resource management and can positively impact the ultimate goals of university entrepreneurship support, such as regional economic development and job creation.

  • PDF

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

A Study on the Women's Bodysuit Sleeve Block Construction Using Stretch fabrics (Stretch 소재를 사용한 여성용 Bodysuit Sleeve 원형 설계에 관한 연구)

  • Park Gin-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1535-1545
    • /
    • 2005
  • The study aimed firstly, to develop the women's bodysuit sleeve block construction method adopting the appropriate pattern reduction rates according to the fabric stretch property. Secondly, the details applied to the bodysuit sleeve block drafting (Dr the educational and industrial usage were proposed. For these, several distinguishing bodysuit sleeve pattern making methods(i.e. Joseph-Armstrong: T1, Shoben & Ward: T2, Esmod: T3 and Mixed Joseph-Armstrong: T4) were analyzed and divided into two categories that adopt 1) the equally (i.e., T1) and 2) the differently(i.e., T2, T3 & T4) distributed front and back armhole length measurements. Women's sleeve samples were made for the research using the same stretch fabric($50\%\;and\; 70\%$ in wale and course each) to the previous research. A group comprising 5 relevant experts evaluated the fit and comfort features of the samples. Experiments analyzed the appearance of sleeve samples focused on total 13 evaluation parts(including the front/side/back fit tolerance, sleeve centre line, sleeve length, appropriateness of the sleeve appearance balanced with the bodysuit and etc.): and performed the comfort test evaluating three kinds(vertical-front/vertical-side/ horizontal) of arm movements. The most appropriate bodysuit sleeve to fulfil the original aims of the study was suggested. The findings and suggestions throughout the study were: 1) the measurements and required reduction rates for the bodysuit sleeve block developed: outer sleeve length (with 1.0 RR), crown height(with 0.7 RR), front and back armhole lengths measured on the bodysuit blocks ($0\%$ ease amount), elbow width(0.9/0.95 RR), wrist girth measurements(from $12\%\;to\;18\%$ tolerances can be given to): and 2) the differently distributed front and back armhole length measurements resulted in the better fit and comfort through the research.