• 제목/요약/키워드: DR-3

검색결과 1,318건 처리시간 0.025초

Unexpected Presence of Blastocystis Subtype 1-3 DNA in Human Vaginal and Sperm Samples Coinfected with Trichomonas vaginalis

  • Villalobos, Guiehdani;Sanchez-Aguillon, Fabiola;Carmona-Maldonado, Marcia Veronica;Gonzalez-Arenas, Nelly Raquel;Lopez-Escamilla, Eduardo;Hernandez-Castro, Rigoberto;Romero-Valdovinos, Mirza;Martinez-Flores, Williams Arony;Ramirez-Hinojosa, Juan Pablo;Maravilla, Pablo;Martinez-Hernandez, Fernando
    • Parasites, Hosts and Diseases
    • /
    • 제60권3호
    • /
    • pp.195-200
    • /
    • 2022
  • There have been few reports on extra-enteric infections by Blastocystis STs and none have been molecularly identified in samples from human reproductive organs. We report for the first time the identification of 3 different subtypes of Blastocystis (ST1-3) in vaginal and sperm samples, from patients infected with Trichomonas vaginalis. Blastocystis STs were identified by PCR-sequencing and by phylogenetic inferences using 28 vaginal swab samples and 7 sperm samples from patients trichomoniasis. Blastocystis STs were identified in 6 of 28 vaginal swabs (21.4%) and in 3 of 7 sperm samples (42.8%). In both biological samples, STs 1-3 were found; one vaginal sample showed subtype co-infection with ST1 and ST3. High genetic variation was observed in the sequences obtained and no specific clustering in the phylogenetic trees was detected. Most of the haplotypes identified were placed far from the main dispersal centers. Our finding suggested that incorrect cleaning of the genital area or a contamination by combination of anal and vaginal intercourse.

난소암에서 봉독이 세포자멸사와 JAK2/STAT3 Pathway의 억제에 미치는 영향 (Effect of Bee Venom Death Receptor Dependent Apoptosis and JAK2/STAT3 Pathway in the Ovarian Cancer)

  • 안병준;송호섭
    • Journal of Acupuncture Research
    • /
    • 제29권1호
    • /
    • pp.47-59
    • /
    • 2012
  • 목적 : 이 연구는 봉독이 사람의 난소암 세포인 SKOV3와 PA-1에서 death receptor의 발현을 높여 세포자멸사를 촉진함으로써 암세포의 성장을 억제하는지 밝히고자 하였다. 방법 : 난소암의 세포자멸사의 관찰에는 DAPI, TUNEL staining assay를 시행하였으며, 세포자멸사 조절 단백질의 변동 관찰에는 western blot analysis를 시행하였고, 난소암 세포에서 death receptor의 변화를 관찰하기 위해 RT-PCR analysis를 시행하였다. 결과 : 1. DAPI, TUNEL staining assay 결과, 봉독은 투여량에 따라 세포자멸사의 유도를 통해 SKOV3와 PA-1 난소암세포의 증식을 억제하였고, 세포자멸사와 동반하여 DR4와 DR6의 발현이 두 암세포 모두에서 증가하였고, DR3의 출현은 PA-1 세포에서 증가하였다. 2. Death Receptor의 발현 증가에 따라 caspase-3, 8, 9 and Bax를 포함하는 세포자멸사 촉진 단백질의 발현이 동반하여 상승하였고 JAK2, STAT3의 인산화와 Bcl-2의 발현은 억제되었다. 3. siRNA 처리 시 봉독에 의한 DR3, DR4, DR6 발현증가와 STAT3의 활성억제가 역전되었다. 결론 : 이러한 결과는 봉독이 난소암 세포에서 DR3, DR4, DR6의 증가와 JAK2/STAT3 pathway의 억제를 통하여 세포자멸사를 유발한다는 것을 시사하며, 난소암의 예방과 치료에 효과적으로 활용될 수 있을 것으로 기대된다.

갑상선 질환들에서 여포세포의 HLA-DR발현 (Thyrocyte HLA-DR Expression in Variety of Thyroid Diseases)

  • 장은숙;손수상;조승제;김인호;김상표;강중신
    • 대한두경부종양학회지
    • /
    • 제13권1호
    • /
    • pp.16-23
    • /
    • 1997
  • Although normal thyroid epithelial cells do not constitutively express HLA-DR antigen, their expression in wide spread within thyroid glands obtained from the human with autoimmune thyroid disease and with many neoplastic thyroids. We have, therefore, studied immunohistochemically with regard to the expression of HLA-DR antigen of thyroidectomy specimens from 50 patients of various thyroid diseases with use of paraffin-embedded tissue. One or two sections from each case were stained with commercially available mouse monoclonal antibody for class II HLA-DR antigen(HLA-DR/Alpha, DAKO) and examined by semiquantitative counting system for thyrocytes, neoplastic thyrocytes and other cells expressing HLA-DR antigen. All patients with lymphocytic thyroiditis(2/2) and diffuse hyperplasia(Graves' disease)(5/5), most patients with Hashimoto's disease(9/ll) expressed HLA-DR antigens in thyrocyte with abundant HLA-DR expressing lymphocytic infiltrates with lymph follicle formation in its vicinity or adjacent to the lesion. Most patients with papillary carcinoma(9/1l) had HLA-DR antigen detected in malignant thyrocytes ; while follicular carcinoma(0/3) and follicular adenoma(0/5) did not have detactable HLA-DR immunoreactivity. Adenomatous goiter(3/7) had HLA-DR antigen detected focally in lesser than half cases. Conversely, in four papillary carcinomas and three adenomatous goiters, HLA-DR expression of thyrocytes was found in the absence of HLA-DR expressing lymphoid infiltrates. In such cases therefore other factors more than thyroid autoimmunity must be causative for HLA-DR immunoreactivity. The results of this study indicate as follows. 1) The expression of HLA-DR on thyrocytes involved in autoimmune reactions appeared to be secondary to cytokine release from associated lymphocytic infiltrates. 2) Thyrocytes in thyroid lesions with equal degrees of lymphocytic infiltration without HLA­DR expression exhibited no HLA-DR immunoreactivity. 3) In neoplastic thyrocytes, most papillary carcinoma(9/11) exhibited detactable HLA-DR expression, while follicular carcinoma/adenoma(0/3/0/5) exhibited no detactable HLA-DR immunoreactivity which suggest the existence of divergent mechanisms inducing and modulating HLA-DR expression of different types of neoplastic thyrocytes.

  • PDF

ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구 (A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom)

  • 홍동희;정홍량;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.241-247
    • /
    • 2006
  • 최근 유방 영상 검사는 의료영상저장전송시스템(Picture Archiving and Communication System, PACS)의 도입과 특수의료장비에 관한 정도관리 실시로 인해 Computed Radiography(CR)과 Digital Radiography(DR)에 관한 관심도와 이용도가 증가하고 있는 추세이다. 본 연구는 유방영상검사에 이용되고 있는 각 시스템별 검출기의 영상 화질을 정도관리 시 사용되는 ACR 팬텀을 이용하여 비교 분석하였다. 평가 방법은 심리적인 방법으로 ACR 팬텀을 이용한 영상의 수치 값을 SPSS 통계프로그램을 이용하여 유의성과 신뢰도를 분석한 결과는 다음과 같다. 1. Fiber에서는 Screen-Film인 경우 3.9점, CR($50\;{\mu}m$)인 경우 4.2점, CR($100\;{\mu}m$)인 경우 3.2점, DR인 경우 4.2점을 얻어 CR($50\;{\mu}m$), DR, Screen-Film, CR($100\;{\mu}m$)순으로 높은 점수를 받았다(P<0.05). 2. Calcification은 Screen-Film인 경우 2.7점, CR($50\;{\mu}m$)인 경우 2.5점, CR($100\;{\mu}m$)인 경우 2.0점, DR인 경우 2.9점을 얻어 DR, Screen-Film, CR($50\;{\mu}m$), CR($100\;{\mu}m$) 순으로 높은 점수를 받았다(0.025(P<0.05). 3. Mass는 Screen-Film인 경우 3.8점, CR($50\;{\mu}m$)인 경우 3.8점, CR($100\;{\mu}m$)인 경우 3.6점, DR인 경우 4.5점을 얻어 DR, CR($50\;{\mu}m$), Screen-Film, CR($100\;{\mu}m$) 순으로 높은 점수를 받았다(P<0.1). 4. 합계점수 평가는 Screen-Film인 경우 10.4점, CR($50\;{\mu}m$)인 경우 10.6점, CR($100\;{\mu}m$)인 경우 8.7점, DR인 경우 11.3점을 얻어 DR, CR($50\;{\mu}m$), Screen-Film, CR($100\;{\mu}m$) 순으로 높은 점수를 받았다. 이상의 결과는 DR, Screen-Film시스템이 CR($100\;{\mu}m$)에 비해 화질이 우수하다는 것을 알 수 있다. 하지만 DR은 소자에 의한 불안정성, Screen-Film은 artifact에 의한 화질 저하 등 단점을 가지고 있으며, 화질 저하가 문제였던 CR시스템 중 Dual-Side방식의 CR($50\;{\mu}m$)을 사용한 경우에는 Screen-Film 시스템과 차이가 없는 것으로 나타났다. 향후 방사선 영상검사가 디지털화 되는 추세이므로 유방영상검사도 각 시스템의 발전과 보완이 필요할 것으로 사료된다.

  • PDF

Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구 (A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System)

  • 홍선숙;김호철
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.247-253
    • /
    • 2013
  • 본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.

F/S시스템과 DR시스템의 화질과 피폭선량 비교에 관한 검토 (Study on image quality and dosage comparison of F/S system and DR system)

  • 김선칠;정재은
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권3호
    • /
    • pp.7-11
    • /
    • 2003
  • 방사선과에 도입된 새로운 디지털 의료 영상 시스템은 많은 변화를 요구하고 있다. 기존의 F/S 시스템에서 부족하거나, 예측하지 못하는 일부분을 대체로 만족하는 수준에 이르렀다. 하지만, 영상의 질과 환자의 피폭선량에서는 아직도 구체적인 자료가 제시되지 않고 있는 것이 현실이다. 이에 본 연구는 기존의 F/S 시스템의 의료 영상과 디지털 의료 영상을 비교하는데 있어서 환자의 피폭선량의 관점에서 실험을 하였으며, 실험결과 값을 이용하여 보다 우수한 환자 서비스 개선을 위한 DR 시스템의 영상의 질과 피폭선량의 측면에서 자료를 제시하고자 연구하였다.

  • PDF