• 제목/요약/키워드: DR-3

Search Result 1,318, Processing Time 0.135 seconds

Unexpected Presence of Blastocystis Subtype 1-3 DNA in Human Vaginal and Sperm Samples Coinfected with Trichomonas vaginalis

  • Villalobos, Guiehdani;Sanchez-Aguillon, Fabiola;Carmona-Maldonado, Marcia Veronica;Gonzalez-Arenas, Nelly Raquel;Lopez-Escamilla, Eduardo;Hernandez-Castro, Rigoberto;Romero-Valdovinos, Mirza;Martinez-Flores, Williams Arony;Ramirez-Hinojosa, Juan Pablo;Maravilla, Pablo;Martinez-Hernandez, Fernando
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.3
    • /
    • pp.195-200
    • /
    • 2022
  • There have been few reports on extra-enteric infections by Blastocystis STs and none have been molecularly identified in samples from human reproductive organs. We report for the first time the identification of 3 different subtypes of Blastocystis (ST1-3) in vaginal and sperm samples, from patients infected with Trichomonas vaginalis. Blastocystis STs were identified by PCR-sequencing and by phylogenetic inferences using 28 vaginal swab samples and 7 sperm samples from patients trichomoniasis. Blastocystis STs were identified in 6 of 28 vaginal swabs (21.4%) and in 3 of 7 sperm samples (42.8%). In both biological samples, STs 1-3 were found; one vaginal sample showed subtype co-infection with ST1 and ST3. High genetic variation was observed in the sequences obtained and no specific clustering in the phylogenetic trees was detected. Most of the haplotypes identified were placed far from the main dispersal centers. Our finding suggested that incorrect cleaning of the genital area or a contamination by combination of anal and vaginal intercourse.

Effect of Bee Venom Death Receptor Dependent Apoptosis and JAK2/STAT3 Pathway in the Ovarian Cancer (난소암에서 봉독이 세포자멸사와 JAK2/STAT3 Pathway의 억제에 미치는 영향)

  • Ahn, Byeong-Joon;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.29 no.1
    • /
    • pp.47-59
    • /
    • 2012
  • 목적 : 이 연구는 봉독이 사람의 난소암 세포인 SKOV3와 PA-1에서 death receptor의 발현을 높여 세포자멸사를 촉진함으로써 암세포의 성장을 억제하는지 밝히고자 하였다. 방법 : 난소암의 세포자멸사의 관찰에는 DAPI, TUNEL staining assay를 시행하였으며, 세포자멸사 조절 단백질의 변동 관찰에는 western blot analysis를 시행하였고, 난소암 세포에서 death receptor의 변화를 관찰하기 위해 RT-PCR analysis를 시행하였다. 결과 : 1. DAPI, TUNEL staining assay 결과, 봉독은 투여량에 따라 세포자멸사의 유도를 통해 SKOV3와 PA-1 난소암세포의 증식을 억제하였고, 세포자멸사와 동반하여 DR4와 DR6의 발현이 두 암세포 모두에서 증가하였고, DR3의 출현은 PA-1 세포에서 증가하였다. 2. Death Receptor의 발현 증가에 따라 caspase-3, 8, 9 and Bax를 포함하는 세포자멸사 촉진 단백질의 발현이 동반하여 상승하였고 JAK2, STAT3의 인산화와 Bcl-2의 발현은 억제되었다. 3. siRNA 처리 시 봉독에 의한 DR3, DR4, DR6 발현증가와 STAT3의 활성억제가 역전되었다. 결론 : 이러한 결과는 봉독이 난소암 세포에서 DR3, DR4, DR6의 증가와 JAK2/STAT3 pathway의 억제를 통하여 세포자멸사를 유발한다는 것을 시사하며, 난소암의 예방과 치료에 효과적으로 활용될 수 있을 것으로 기대된다.

Thyrocyte HLA-DR Expression in Variety of Thyroid Diseases (갑상선 질환들에서 여포세포의 HLA-DR발현)

  • Chang Eun-Sook;Sohn Soo-Sang;Cho Seung-Che;Kim In-Ho;Kim Sang-Pyo;Kang Joong-Shin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.13 no.1
    • /
    • pp.16-23
    • /
    • 1997
  • Although normal thyroid epithelial cells do not constitutively express HLA-DR antigen, their expression in wide spread within thyroid glands obtained from the human with autoimmune thyroid disease and with many neoplastic thyroids. We have, therefore, studied immunohistochemically with regard to the expression of HLA-DR antigen of thyroidectomy specimens from 50 patients of various thyroid diseases with use of paraffin-embedded tissue. One or two sections from each case were stained with commercially available mouse monoclonal antibody for class II HLA-DR antigen(HLA-DR/Alpha, DAKO) and examined by semiquantitative counting system for thyrocytes, neoplastic thyrocytes and other cells expressing HLA-DR antigen. All patients with lymphocytic thyroiditis(2/2) and diffuse hyperplasia(Graves' disease)(5/5), most patients with Hashimoto's disease(9/ll) expressed HLA-DR antigens in thyrocyte with abundant HLA-DR expressing lymphocytic infiltrates with lymph follicle formation in its vicinity or adjacent to the lesion. Most patients with papillary carcinoma(9/1l) had HLA-DR antigen detected in malignant thyrocytes ; while follicular carcinoma(0/3) and follicular adenoma(0/5) did not have detactable HLA-DR immunoreactivity. Adenomatous goiter(3/7) had HLA-DR antigen detected focally in lesser than half cases. Conversely, in four papillary carcinomas and three adenomatous goiters, HLA-DR expression of thyrocytes was found in the absence of HLA-DR expressing lymphoid infiltrates. In such cases therefore other factors more than thyroid autoimmunity must be causative for HLA-DR immunoreactivity. The results of this study indicate as follows. 1) The expression of HLA-DR on thyrocytes involved in autoimmune reactions appeared to be secondary to cytokine release from associated lymphocytic infiltrates. 2) Thyrocytes in thyroid lesions with equal degrees of lymphocytic infiltration without HLA­DR expression exhibited no HLA-DR immunoreactivity. 3) In neoplastic thyrocytes, most papillary carcinoma(9/11) exhibited detactable HLA-DR expression, while follicular carcinoma/adenoma(0/3/0/5) exhibited no detactable HLA-DR immunoreactivity which suggest the existence of divergent mechanisms inducing and modulating HLA-DR expression of different types of neoplastic thyrocytes.

  • PDF

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Study on image quality and dosage comparison of F/S system and DR system (F/S시스템과 DR시스템의 화질과 피폭선량 비교에 관한 검토)

  • Kim, Sun-Chil;Jung, Jae-Eun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.7-11
    • /
    • 2003
  • Currently, many hospitals are hastening to introduce digital radiography systems. This is a direct result of the intentions to improve medical services and to digitalize radiology information systems, and is also leading to the improvement of medical imaging technology. Throughout F/S system's long history, many people have researched the image quality and dosage concerning these systems, and as a result, huge improvements in the dosage of patients were possible. Similarly, I believe that DR systems need the same kind of effort. Of course, decreases in dosage that ignore image quality are unthinkable. The results of experiments conducted by five hospitals during a period of 3 months brought to us the conclusions listed below. 1. Based on the comparison and analysis of the exposure control of F/S systems and DR systems, DR systems generally showed higher exposure control for parts of the phantom that became thicker, and the exposure control improved rapidly as the thickness increased. 2. DR systems still proved to be somewhat deficient in resolution measurements compared to existing F/S systems. The image processing part of DR systems contributed much to these result. 3. Under conditions used clinically, the dosage measurements of DR systems were generally higher regardless of region. 4. According to the evaluation of image quality, DR systems showed a higher degree of satisfaction as the thickness of the region became thinner. As mentioned above and based on the mutual relationship experiments between the dosage and image quality of F/S systems and DR systems, research to increase the satisfaction of DR systems must be considered.

  • PDF