Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.

A Study of Outer-ring Galaxies within z<0.05 (적색편이 z<0.05의 외부고리 은하에 대한 연구)

  • Chang, Hunhwi;Sohn, Jungjoo;Ahn, Hongbae
    • Journal of the Korean earth science society
    • /
    • v.41 no.3
    • /
    • pp.211-221
    • /
    • 2020
  • This study classified outer-ring galaxies using 25,308 galaxies within z=0.05 from the SDSS DR7, which are larger than Rpet>6 arcsec and whose minor-to-major axis ratio (b/a)<0.6. We selected 531 galaxies that have ring-like structures by visual inspection of the color images of 25,308 galaxies; these galaxies with ring-like structures served as a primary sample from which we selected 90 outer-ring galaxies. The final sample of 69 outer-ring galaxies was selected by examining the photometric properties of the candidate galaxies. Their properties were determined by conducting surface photometry on their u, g, r, i, and z images. The frequency of the outer-ring galaxies was found to be 0.3% of the local galaxies. We examined the environment of the outer-ring galaxies using two measures of environment, namely, the projected distance to the nearest-neighbor galaxy and the local background density. We did not observe any notable difference between outer-ring and other galactic environments.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

Management of oral and maxillofacial radiological images (Dr. Image를 이용한 구강악안면방사선과 의료영상 관리)

  • Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.129-134
    • /
    • 2002
  • Purpose : To implement the database system of oral and maxillofacial radiological images using a commercial medical image management software with personally developed classification code. Materials and methods : The image database was built using a slightly modified commercial medical image management software, Dr. Image v.2.1 (Bit Computer Co., Korea). The function of wild card '*' was added to the search function of this program. Diagnosis classification codes were written as the number at the first three digits, and radiographic technique classification codes as the alphabet right after the diagnosis code. 449 radiological films of 218 cases from January, 2000 to December, 2000, which had been specially stored for the demonstration and education at Dept. of OMF Radiology of Dankook University Dental Hospital, were scanned with each patient information. Results: Cases could be efficiently accessed and analyzed by using the classification code. Search and statistics results were easily obtained according to sex, age, disease diagnosis and radiographic technique. Conclusion : Efficient image management was possible with this image database system. Application of this system to other departments or personal image management can be made possible by utilizing the appropriate classification code system.

  • PDF

The Usefulness Analysis of Applying Dose Mode in Mammography Women of Childbearing Age (가임기 여성의 유방촬영에서 Dose mode 적용의 유용성 분석)

  • Lee, So-Ra;Son, Soon-Lyong;Chung, Jae-Yoen;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.19-23
    • /
    • 2013
  • Purpose : Automatic exposure system(AOP mode) in DR Mammography of the STD and DOSE apply to women of childbearing age, the average glandular dose(AGD) and image quality by comparing was to demonstrate the usefulness of DOSE. Materials and Methods : Of the under 40 age 108 patients who visit to our hospital and examined STD and DOSE mammography from January 2008 to July 2013. AGD was obtained by DICOM header information provided by GE Senographe DS. STD and DOSE images were evaluated with obtained patients, Image J program was compared by calculating the SNR. Results : The average AGD of DOSE mode was 0.99mGy, and which decreased by 19% comparing to that of STD mode which was 1.18mGy. The two the average AGDs indicated statistically significant difference(p< .01). The average SNR of STD was 40.26, DOSE displayed, and to 39.68 in, there was no statistical significance. Results : The average AGD using DOSE mode which is one of DR mammography AOP modes decreased by comparing to that of STD mode showing no difference in image quality. The use of DOSE is considered to be useful.

  • PDF

The Relationship of Radiation Dose and Image Quality According to the Condition of Chest PA

  • Son, Jin-Hyun;Min, Jung-Whan;Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.165-169
    • /
    • 2011
  • The purpose of this study is to compare the measurement result of radiation dose by using standard thoracic phantom and ionization chamber to advice proposal in the shooting condition of chest PA projection at hospitals recently. And to understand the change between radiation dose and resolution in different conditions. The period this study was from August 2010 to September 2010 and the subjects of the study was 3 general hospitals, 4 personal hospitals and 1 laboratory at the college. Finally we study with 6 DR, 1 CR, and 4 F/S equipments. Most hospitals met advice proposal, but some of the hospitals exceed advice dose from the result of our study. We can lower radiation dose about 25% when kVp is lowered about 20% in DR equipment. And we can lower radiation dose about 50% when mAs is lowered about 35%. The image quality was similar to the original in the study. Most hospitals which exceed advice dose were personal hospitals. The reason why it happened is that radiation dose for chest PA projection at personal hospitals is higher than general hospitals and the personal hospitals' equipments are older than general hospitals' equipments. We guess that patients' radiation dose of chest PA projection can be lowered from the result.

  • PDF

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF

A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography (진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교)

  • Lee, Won-Jeong;Ko, Kyung-Sun;Park, Jai-Soung;Kim, Sung-Jin;Chu, Sang-Deok;Park, So-Young;Choi, Byung-Soon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • Digital radiography has been replacing rapidly the analog radiography for diagnosis of pneumoconiosis. The purpose of this study is to compare quality control of digital radiography (DR) and analog radiography (AR) for chest radiography in medical institution for pneumoconiosis (MIP) For the first time, we visited MIP to evaluate the chest radiography which is used for patients with pneumoconiosis, including equipment, technical parameters and reading environment. There were 33 institutions. DR and AR were installed in 24 and 9 institutions, respectively. Between DR and AR, we compared the radiological technique (RT), image quality (IQ) and reading environment (RE) to use the guideline published by Occupational Safety and Health Research Institute (OSHRI). The image quality was rated by two experienced chest radiologists for pneumoconiosis with certified from OSHRI. The chest radiography equipment was not significantly difference between AR and DR, but there were significantly difference in tube voltage and grid ratio used for chest radiography except to tube current, exposure time. Statistically, DR is significantly higher in RT(70.3 vs. 43.8, p = 0.009), RE(77.7 vs. 33.3, p = 0.004) than AR, but it's not significantly difference in IQ (65.6 vs. 52.8, p = 0.050). AR and DR in RT were passed 33.3%, 75.0% respectively (p = 0.044) and 44.4%, 79.2% (p = 0.090) in IQ and 44.4%, 91.7% (p = 0.009) in RE. In MIP, DR needs to replace AR in diagnosis of pneumoconiosis.