An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

A Study on Useful Application of Stitching Method for Full-Length Examination of the Femur (대퇴골의 전장검사 시 stitching method의 적용에 관한 유용성 연구)

  • Noh, Ji-Sook;Jung, Ji-Hoon;Kim, Sung-Kil;Jung, Myung-Jin
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2011
  • The Full-length examination of the femur sometimes does not show all of the femur because of the limited width in collimator and size of detectors although it is located in the diagonal direction. Aim of this study is to identify usefulness of the method of combining images which obtained from two radiographic images containing the femoral head and condyle respectively. Our group interviewed 30 radiological technologists who used both palliative DR method and SM method in their examinations of the femur of patients who were carried to the emergency rooms in Gwang-ju city from August 2007 to November 2009. We evaluated twenty images according to the contraction of femoral neck, turning of knee joints and inclusion of the femur. The examination were performed by two radiologists and six radiological technologists who have more than ten years of career. The results are as follows: SM method was graded with higher score for examination time, number of examiners, emaciation, retake and patients' discomfort (p< 0.001) while the. SM method was scored higher than the palliative DR method in the palliative DR method for examination of long bone.

A Study of Quality Control Environment of Mammography (유방촬영의 화질관리 환경에 대한 고찰)

  • Hwang, In-Sun;Kim, Young-Keun;Joo, Hyung-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • The purpose of this study was to survey and test quality control of mammography system. The conclusion of this study is as follows ; First, The rate of pass for phantom image test shows that Film-Screen mammography system(F/S) and computed mammography system(CR) is 80%, Indirect digital mammography system(DR) is 100%. Second, The test of exposure dose shows that F/S is 921 mR. CR is 1,140 mR, DR is 474 mR. The grade of this testament is CR > F/S > DR. Third, The test of average glandular dose shows that F/S is 1,336 mGy, CR is 1,635 mGy, DR is 1,26 mGy. The grade of this testament is CR > F/S > DR. Fourth, The testament of resolution shows as follows F/S is 11~13 Lp/mm, CR is 4~5 Lp/mm, and DR is 5~7 Lp/mm(F/S > DR > CR) Fifth, The survey of projection, cassette, development and reading shows that user are indifference.

  • PDF

The Study on the Attenuation of X-ray and Imaging Quality by Contents in Stomach (위장내 음식물에 따른 방사선 감약 및 화질에 관한 연구)

  • Dong, Kyung-Rae;Ji, Youn-Sang;Kim, Chang-Bok;Choi, Seong-Kwan;Moon, Sang-In;Dieter, Kevin
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • This study examined the change in the attenuation of X-rays with the ROI (Region of Interest) in DR (Digital Radiography) according to the stomach contents by manufacturing a tissue equivalent material phantom to simulate real stomach tissue based on the assumption that there is some attenuation of X-rays and a difference in imaging quality according to the stomach contents. The transit dosage by the attenuation of X-rays decreased with increasing protein thickness, which altered the average ROI values in the film and DR images. A comparison of the change in average ROI values of the film and DR image showed that the image in film caused larger density changes with varying thickness of protein than the image by DR. The results indicate that NPO (nothing by mouth) is more important in film system than in DR system.

  • PDF

ROC Analysis of Simulated Chest Lesions for Computed Radiography and Digital Radiography at Various Tube Voltages (다양한 관전압에 따른 CR과 DR 모의병변 흉부 영상의 ROC 평가)

  • Cho, Hyo-Min;Kim, Hee-Joung;Lee, Chang-Lae;Jung, Ji-Young;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.298-304
    • /
    • 2008
  • Current digital radiographic systems are rapidly growing in clinical applications. The purpose of this study was to evaluate the diagnostic performance of computed radiography (CR) and digital radiography (DR) at different tube voltages in the detection of simulated chest lesions. Patterns of simulated interstitial lung disease, incipient infiltration, and nodules were superimposed over an anthropomorphic chest phantom. A simulated chest phantom radiograph was obtained with CR and DR at different tube voltages (70 kV, 90 kV, and 120 kV). A total of 18,000 observations were analyzed using a receiver operating characteristic (ROC) analysis. The detection of all lesions showed higher $A_z$ values at 70 kV than 120 kV with CR. For the DR, mean $A_z$ values at 70 kV were higher than other tube voltages not all lesions but for micro-nodule interstitial lung disease, linear interstitial lung disease, and incipient infiltration. Based on these results, a clinical study should be performed to judge the use of suitable tube voltage according to the type of detector system and lesions.

  • PDF

Research for The Environmental Optimization of Dose and Image quality in Digital Radiography (디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구)

  • Lee, Kwang Jae;Kim, MinGi;Lee, Jong Woong;Kim, Ho Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography (DR) has improved a quality of resolution based on a wide dynamic range, high detective quantum efficiency (DQE), and modulation transfer function (MTF), compared with film/screen(F/s). Unlike expectation that a low level of radiation can be used in examination, high level of signal to noise ratio(SNR) due to over-exposure caused increase of exposed dose to patients. Also, the auto exposure control (AEC) using Kilovolage(kVp) in F/S can cause over-exposure. Hence, in this study, we proposed a proper method for using DR, in which effect of tubing Kilovolage on device's image, DR MTF measurement with changes of tubing current (mA), and the quantitative evaluation of skull phantom captured images' PSNR were evaluated. Changes of contrast with tubing Kilovolage can be improved by retouching, and MTF changes according to tubing current(1.41~1.39 lp/mm in 50% area, and 3.19~2.8 lp/mm in 10% area) does not influence on resolution of image. As a result, high tubing Kilovoltage, and tubing current will be suitable to use of DR.

Pollution Research about Radiology radiographic laboratory (방사선 영상학 실습실 오염실태 조사 (D대학교 DR장비와 방사선 발생장치, Cassette 오염실태 조사))

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.69-76
    • /
    • 2013
  • We checked the existence of bacteria at DR equipment, radiation generator and cassette in 'D university' to propose optimized management method for bacteria and disinfection at DR equipment, radiation generator and cassette at used in radiographic laboratory of the department of radiology. The infected region is treated by alcohol and cresol and compared before spraying and after spraying for 1, 3, 5 and 10 minutes. As time goes on, amount of bacteria colony decreases significantly. The Cresol is useful to disinfect the diminutive devices. However alcohol disinfection, at least 5 minutes later, and hand washing before practical training and shooting image is recommended due to the big and fixed radiography equipment which cause the soakage.

  • PDF

DWT Analysis of Scatter-Ray Due to the Changed Energy on Digital Medical Images (디지털 의료영상에서 에너지 변화에 따른 산란선의 DWT 분석)

  • Kim, Jisun;Jung, Jaeeun;Ahn, Byeoungju
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.65-74
    • /
    • 2014
  • This study extracts characteristics of signal by wavelet transform to prove that the Compton scattering, occurred by changed the energy, influenced a picture. We also analyzed the extracted data and evaluated how much the picture of scatter-rays was affected by a change of tube voltage. For this study, we wrote a program with MatLap which is engineering tool and evaluated with the program on variation of scattered-rays due to increased tube voltage. The evaluation result shows both CR and DR have frequency changes of high frequency area by tube voltage variations and it proved that Compton scattering influences the picture. In conclusion, according to this study indicates that DR is more sensitive to radiation with high energy than CR. Therefore, the research on DR detector needs to be advanced as actual condition of clinical setting is being changed to DR circumstance gradually. From the result of this study, we expect that assessment method of the image quality using MatLab Tool becomes the official assessment method and very useful method.