• Title/Summary/Keyword: DQ

Search Result 325, Processing Time 0.025 seconds

Human Leukocyte Antigen-DQ Genotyping in Pediatric Celiac Disease

  • Stuti Pareek;Raj Kumar Gupta;Abhinav Sharma;Sandhya Gulati
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.1
    • /
    • pp.50-57
    • /
    • 2023
  • Purpose: The purpose of this study was to determine the pattern of human leukocyte antigen (HLA)-DQ genotype in children diagnosed with celiac disease (CD) (biopsy proven), and to compare this with a control group; and secondarily, to correlate HLA genotypes with clinical profiles of CD. Methods: This cross-sectional comparative observational study included 26 controls and 52 patients diagnosed with CD who presented at Sir Padampat Mother and Child Health Institute, Jaipur, from May, 2017 to October, 2018. HLA DQ genotype was assessed for each patients and correlated with clinical profiles. Results: HLA DQ2/DQ8 genotypes were significantly more common in CD (present in 100.0% cases) than in controls (23.1%) in Northern India (Rajasthan). When HLA DQ2.5 and DQ8 were present together, individuals had significantly more atypical presentations and severe findings on duodenal biopsy. Similarly, patients with the HLA DQ 2.5 genotype were also predisposed to more severe endoscopic findings, while HLA DQ2.2 predisposed them to less severe biopsy findings. HLA DQ8 was significantly associated with later age at diagnosis (>5 years) and shorter stature. The highest HLA DQ relative risk (RR) for CD development was associated with HLA DQ2.5 and DQ2.2 in combination, followed by HLA DQ2.5 and DQ8 in combination, while HLA DQx.5 and HLA DQ2.2 together had the lowest risk. Conclusion: HLA DQ2/DQ8 genotypes are strongly associated with pediatric CD patients in northern India. These genotypes and their combinations may be associated with different clinical presentations of CD, and may help predict severity of CD.

Research on The System Software Quality Certification Implementation Plan of DQ Mark Certification (DQ마크 인증제도의 시스템 소프트웨어 품질인증 수행 방안 연구)

  • Yun, Jae-Hyeong;Song, Chi-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.85-91
    • /
    • 2021
  • The DAPA (Defense Acquisition Program Administration) has been operating the DQ mark certification since 2012 to certify the superior technology and quality of munitions. On the other hand, the current DQ mark certification can not directly provide DQ mark certification to software because it is impossible to verify the quality of software alone. Therefore, this study analyzed domestic/overseas software quality evaluation/certification standards to find a way to verify the quality of software in the DQ mark certification. Among them, the method of applying the GS certification according to the international standard ISO/IEC 25000 series to the DQ mark certification was suggested as an improvement plan, and DQ mark certification verified the quality of software and provided certification. An attempt was made to expand the certification scope of DQ mark certification. This paper proposes that the DQ mark can be given to the system software by introducing GS certification to the DQ mark certification. To this end, an improved procedure for omitting the factory audit and verification by submitting a GS certificate for product evaluation is proposed. This is expected to increase defense exports using the granted DQ mark and improve the quality of defense software products through GS certification.

포커스-e기업 - (주)이오시스템, '단안형 야간투시경' 품질보증 DQ마크 획득

  • 한국광학기기협회
    • The Optical Journal
    • /
    • s.142
    • /
    • pp.39-39
    • /
    • 2012
  • (주)이오시스템이 지난 9월 20일 국방기술품질원 강당에서 진행된 '2012년 1차 DQ마크(Defense Quality) 인증서 수여식'에서 단안경 야간투시경에 대한 품질보증 DQ마크를 획득했다. DQ마크 인증은 방위사업청이 국내 납품 실적에도 불구하고 수출 실적의 부족으로 마케팅에 어려움을 겪고 있는 방산업체를 지원하기 위해 수출 잠재력이 우수한 방산 제품에 DQ마크를 부여해 기술력 및 품질을 정부가 인증하는 제도다. 지난 2012년 1월 2일 'DQ마크 인증제도 운영규정'의 제정에 따라 정식 운영이 시작됐으며, 국방기술품질원이 방위사업청으로부터 국제적인 기준(ISO/IEC 17042)에 따라 DQ마크 인증기관으로 공식 지정받은 바 있다.

  • PDF

Maximum Torque Operation of a PM Synchronous Motor for HEV under Parameter Variation (HEV용 영구자석 동기전동기의 상수변동 시 최대토크 운전)

  • Cho, Kwan-Yuhl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5128-5134
    • /
    • 2011
  • This paper investigates the dq current trajectory for maximum torque per ampere(MTPA) operation of an interior PM synchronous motor for HEV(Hybrid Electric Vehicle). Based on the dq current trajectory for the MTPA operation derived from the motor parameters, the change of the MTPA operating point for the variation of the motor parameters including the magnet flux and the dq inductances is considered. The dq current trajectory for MTPA operation is verified through the experiment.

Calculation of the Cubic Crystal Field Splitting 10 Dq in KNiF$_3$. An Integral Hellmann-Feynman Approach (Integral Hellmann-Feynman Approach에 의한 KNiF$_3$의 Cubic Crystal Field Splitting 10 Dq의 계산)

  • Hojing Kim;Hie-Joon Kim
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.6
    • /
    • pp.395-405
    • /
    • 1973
  • By use of an Integral Hellmann-Feynman formula, the cubic crystal field splitting 1O Dq in $KNiF_3$ is calculated from first principles. Numerical values of covalency parameters and necessary integrals are quoted from Sugano and Shulman. The result, 7100$cm^{-1}$, is in excellent agreement with the observed value, 7250$cm^{-1}$. It is found that higher order perturbation energy correction is of the same order of magnitude as 10 Dq itself and is, therefore, essential tin calculating 10 Dq from first principles. It is also found that the point charge potential is the dominant part of the crystal field potential.

  • PDF

Switch Open Fault Diagnosis of Inverter Using Features of dq Currents (dq 전류의 특징을 이용한 인버터의 스위치 개방 고장진단)

  • Kwak, Nae-Joung;Hwang, Jae-Ho;Hong, Won-Pyo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.31-38
    • /
    • 2011
  • Faults of motor drive systems to be used for various industrial applications can cause serious problems. In this paper, a method to diagnose switch open fault of a voltage-fed PWM inverter is proposed. The proposed method normalizes dq current and fault-detection and first classification are performed by mean values of dq phase currents, second classification is performed by features such as the relation of dq phase currents, the ranges of those, the positions of those according to the results, and fault switch is diagnosed with the results. The proposed method performs the simulation for diagnosis of inverter switch open faults with MATLAB and identifies the feasibility of the proposed method. Because the proposed method is implemented by simple algorithms, the proposed algorithm can be embedded in general induction motor drive systems and be used.

The Effect of the Configuration Interaction on 10Dq in a Point Charge Model (점전하 모형에 의한 10Dq 에서의 배치간 작용의 영향)

  • Hojing Kim;Duckhwan Lee
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.1
    • /
    • pp.23-31
    • /
    • 1977
  • For the metal complex of $d^1$ configuration with the octahedrally coordinated ligands, the crystal field parameter, 10Dq, is calculated from first principles within the framework of the crystal field theory. With the point charge model, the configuration interaction is introduced by use of the Shull-L$\"{o}$wdin functions. Through the Integral Hellmann-Feynman Theorem, the higher order effect is visualized. It is found that the higher order effect on 10Dq is about $50{\%}$ of the first order effect. Since 3d function is angularly undistorted and radially equally distorted in $E_g\;and\;T_{2g}$ states, due to the octahedral potential, the calculated 10Dq is still the unique parameter for the splitting.

  • PDF

Modeling and Characteristic Analysis of UPFC Using Circuit DQ Transform (회로 DQ 변환을 이용한 UPFC의 모델링 및 동작특성 해석)

  • Choi, Nam-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1027-1029
    • /
    • 2002
  • UPFC(Unified Power Flow Controller)는 계통의 선로로 전송되는 무효전력과 유효전력을 독립적으로 보상해줄 수 있는 유연송전시스템 기기로, 전력계통 전압 안정화와 위상제어 둥의 목적으로 실용성과 적용성이 뛰어나므로 최근 들어 국내외에서 활발하게 연구 되고 있다. 본 논문에서는 회로 DQ 변환 기법을 적용하여 UPFC를 모델링하고 동작특성 해석한다. 회로 DQ 변환의 결과 정특성 및 동특성을 나타낸는 등가회로를 구할 수 있으며 이로부터 각종 특성식과 설계식을 도출해 낸다. 또한, 제안된 모델링 및 동작특성 해석의 결과의 타당성은 PSIM 시뮬레이션을 통하여 검증한다.

  • PDF

A Study of Pourer Quality Disturbance Compensation using dq Transformation (dq 좌표변환을 이용한 전력외란 보상 연구)

  • Lee, Kyo-Sung;Lee, Yong-Jae;Kim, Do-Hun;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.286-289
    • /
    • 2002
  • In this paper, we use the PI dual control using do transformation(dq stationary frame and dq synchronous rotating frame) for series voltage sag and swell compensation algorithm. Analysis, simulation results are presented for voltage sags and swells on a three-phase unbalanced voltage source.

  • PDF

Circuit DQ Modeling and Analysis of Operating Characteristics for Hybrid Cascade Five-level PWM Rectifier (하이브리드 Cascade 5-레벨 PWM 정류기의 회로 DQ모델링 및 동작특성 해석)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.817-824
    • /
    • 2000
  • This paper presents circuit DQ modeling and analysis of operating characteristics of hybrid cascade multilevel PWM rectifier, especially five-level, without isolation transformers. The circuit DQ transformation changes the original three-phase time varying circuit to stationary equivalent one by employing the synchronously rotating transformation matrix. As a result of circuit DQ modeling, the operating characteristics and some useful design relationships for the system are obtained with ease. That is, the analytic equations for DC voltages and active/reactive power supplied by source with respect to control variables are Presented. Moreover, the DC voltages for the multilevel output generation may be directly built up from AC utility source and the important control equation ensuring 5-level output voltage is obtained. Finally, to confirm the validity of the analysis, MATLAB simulations are carried out and the simulation results show good agreements between analytic predictions and the simulated waveforms.

  • PDF