• Title/Summary/Keyword: DOPPLER

Search Result 2,266, Processing Time 0.035 seconds

A case of the patient treated with Chunmagudung-um who was diagnosed with Vertebrobasilar insufficiency (척추기저동맥부전환자를 천마구등음(天麻鉤藤飮)으로 치료한 치험 1례)

  • Song, Cheol-Min;Chang, Tong-Young;Rhim, Eun-Kyung;Lee, Yun-Jae;Lee, Jung-Sub;Shin, Sun-Ho;Lee, In;Moon, Byung-Soon;Jeong, Hyun-Ae
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.3
    • /
    • pp.699-707
    • /
    • 2005
  • Vertebrobasilar insuffciency(VBI) is also refered to as vertebrobasilar transient ischemic attack(V-B TIA). Vertebrobasilar insufficiency is often undiagnosed or misdiagnosed due to complexity of the symptoms. Transcranial doppler(TCD) can be used to possible to record the blood flow velocities in the cerebral arteries through the intact cranium. Transcranial doppler and magnetic resonance angiography(MRA) are both noninvasive techniques that can be used in vertebrobasilar insufficiency, but transcranial doppler is more sensitive with respect to evaluating stenotic lesion of the arteries than magnetic resonance angiographv. Diagnostic values of transcranial doppler were assessed in patients with vertebrobasilar insufficiency. A case of vertebrobasilar insufficiency is here reported. A 62-year-old man with dizzness, nausea and tremor because of vertebrobasilar insufficiency was admitted at Wonkwang Oriental Medicine Hospital. He was treated with the herbal medicine Chunmagudung-um and with acupunture. Results showed improvement of symptoms and favorable transcranial doppler readings. The process used in this successful treatment is here described.

  • PDF

Improving the frequency domain resolution of Wireless signal for observing the Doppler frequency (도플러 주파수 관찰을 위한 무선 신호의 주파수 영역 해상도 향상)

  • Hong, Yerin;Oh, Hyukjun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2270-2278
    • /
    • 2017
  • There are many research to find not only user data but also physical information about objects or human in radio signals. And we can obtain physical information from the wireless signals such as RSSI (Received Signal Strength Indicator), Doppler frequency and other values. For example, the Doppler frequency is generated by the object moving physically in wireless signals used for communication. By analyzing the Doppler frequency, the moving speed and direction of the object can be predicted. In this paper, we study the previous research which is to detect the moving objects or human using wireless signals, 802.11a signals. We introduce and verify the method to improve the frequency domain resolution of commercial 802.11a receivers to observe the doppler frequency and obtain the information of the moving objects or human.

Evaluation Study on Wind Retrieval Methods from Single-Doppler Radar (단일 도플러 레이더를 이용한 풍속데이타 산출기법에 관한 연구)

  • Lim, Hee-Chang;Lee, Dong-In;Jang, Sang-Min
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.333-343
    • /
    • 2009
  • This study presents the analysis of an atmospheric flow around a single-doppler radar located in a pseudo-site. The use of a doppler radar in meteorological field of wind engineering has become widespread over the last several decades, but it has generally been recognized that the single-Doppler radar yields only one single velocity component - the radial velocity($V_r$) so that some additional hypotheses or simplifications must be necessary to get proper wind forecast. Therefore, in order to get an accurate radial velocity($V_r$) in this study, the existing methods such as VAD(Velocity Azimuth Display) and VARD(Velocity Area Display) are reformulated and applied to match the previous study(Waldteufel and Corbin), which have been an important indicator for retrieving a radar velocity. The results presented in this study include the results from different assessment methods in a peudo-site of different wind fields. Unless the existing method can consider the proper decomposition of radial velocity in the real site, then authors suggest an appropriate curve-fitting to decrease the uncertainty errors by changing a grid adaptation rate or applying a weighting function with respect to the wind angle. It is concluded that provided properly formulated fitting function are used, the wind retrieval from the Doppler radar using VAD and VARD methods can be a viable tool for use in wind engineering problems searching for the wind resources.

Color Doppler Ultrasonogram for the Peripheral Vascular disease in Diabetes Patients (당뇨병 환자의 하지 혈관 질환 검사에서 색도플러 초음파의 이용)

  • Lee, Kyung-Tai;Choi, Yun-Sun;Young, Ki-Won;Bae, Sang-Won;Lee, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.80-85
    • /
    • 2002
  • Purpose: This study is to assess the involvement of vessels in lower extremity in diabetics, using color doppler ultrasonogram. Materials and Methods: Arteries of both lower extremities were divided into 3 groups-large vessel (above-knee arteries), popliteal vessel, and small vessel(below-knee arteries) -, and evaluated using color doppler ultrasonogram in 60 diabetics. In color doppler ultrasonogram, the wave forms of all vessels were divided into 5 grades; grade I was triphasic wave form, grade II was spectral broadening form, grade III was monophasic wave form, grade IV was pulsus tardus et parvus form, grade V was absence of wave. Grade III, IV, V were grouped into vessel obstruction. We reviewed the correlationships among the degree of the peripheral vascular involvement, duration of dibetes, existence of bilaterality, types of dibetes. Results: Bilateral involvement was high in both lower extremity. Luminal stenosis, vascular calcification and vessel obstruction were high incidence in the patients over ten years of diabetic duration. Prevalence of vascular calcification and vessel obstruction were high in the small vessel of ankle level. But, insulin injection was not related to the incidence of vascular abnormality. Conclusion: Color doppler ultrasonogram seems to be useful for evaluation of peripheral vascular status, decision making for necessity of additional test, periodic follow -up tool in diabetes patients.

  • PDF

Different Types of Active Region EUV Bright Points by Hinode/EIS

  • Lee, Kyoung-Sun;Moon, Yong-Jae;Kim, Su-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.28.2-28.2
    • /
    • 2010
  • We have investigated seven Extreme-Ultraviolet (EUV) bright points in the active region (AR 10926) on 2006 December 2 by the EUV imaging spectrometer (EIS) onboard Hinode spacecraft. We determined their Doppler velocities and non-thermal velocities from 15 EUV spectral lines (log T=4.7-7.2) by fitting each line profile to a Gaussian function. We present the Doppler velocity map as a function of temperature which corresponds to a different height. As a result, these active region bright points show two different types of characteristics. Type 1 bright point shows a systematic increase of Doppler velocity from -68 km/s (blue shift) at log T=4.7 to 27 km/s (red shift) at log T=6.7, while type 2 bright points have Doppler velocities in the range of -20 km/s and 20 km/s. Using MDI magnetograms, we found that only type 1 bright point was associated with the canceling magnetic feature at the rate of $2.4{\times}10^{18}$ Mx/hour. When assuming that these bright points are caused by magnetic reconnection and the Doppler shift indicates reconnection out flow, the pattern of the Doppler shift implies that type 1 bright point should be related to low atmosphere magnetic reconnection. We also determined electron densities from line ratio as well as temperatures from emission measure loci using CHIANTI atomic database. The electron densities of all bright points are comparable to typical values of active regions (log Ne=9.9-10.4). For the temperature analysis, the emission loci plots indicate that these bright points should not be isothermal though background is isothermal. The DEM analysis also show that while the background has a single peak distribution (isothermal), the EUV bright points, double peak distributions.

  • PDF

Extraction and analysis of doppler frequency of wind turbines and effect on radar signals (산악지형에 설치된 풍력발전단지에 의한 도플러 주파수 추출 및 분석)

  • Jung, Joo-Ho;Kang, Ki-Bong;Kim, Min;Kim, Jeung-Yuen;Park, Sang-Hong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.947-952
    • /
    • 2015
  • To supplement energy needs and take advantage of renewable energy sources, many wind farms are currently being built in mountainous areas under the supervision of the Korean government. However, operation of these wind farms can cause serious threats to national security due to Doppler modulation from the wind turbines causing interference with military radar operating in the vicinity. Therefore it is necessary to develop methods to analyze the Doppler frequency during the operation of wind turbines and the effect on radar signals. Based on modeling of the mountainous region, blockage analysis, turbine motion and the radar signals, this paper proposes a signal processing method to extract and analyze the Doppler frequency. Simulation results showed the change of Doppler frequency over time caused by the geometry of the mountainous area and the wind turbine.

A Study on Precise Positioning with Doppler Measurements for Ground Transportation System (도플러 측정치를 이용한 육상교통 환경에 적합한 정밀 측위 기법 연구)

  • Lee, Byung-Hyun;Jee, Gyu-In
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.632-639
    • /
    • 2010
  • Ground Transportation is one of the most required field that users need positioning information Especially, more precise position can make smart traffic management possible and bring convenience to users. By advanced wireless network, cars can receive the GPS information of reference station in any tim e and any where. Thus land vehicles are possible to process precise positioning. In general, for precise positioning code and phase measurements are used. But receivers provide not only code and phase measurements but also doppler measurements and Doppler is direct measurement of velocity. In this paper, because velocity is very important information required in Ground Transportation, precise positioning for Ground Transportation is studied. For precise positioning RTK(Real-Time Kinematic) was used and double differenced doppler measurements were added, As a Result, positioning error by multipath and cycle slip was soften. However there still remained Positioning error. Thus smoothing technique using doppler measurement in position domain is used for softening positioning error.

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

THE USE OF LASER DOPPLER FLOWMETER FOR PULP VITALITY TEST (치수생활력 검사를 위한 Laser Doppler Flowmeter의 이용)

  • Su, Wan-Jong;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.562-568
    • /
    • 1998
  • Various diagnostic methods, such as electric pulp test, cold test, test cavity etc., have been used to determine the pulp vitality. At least two or more methods should be used with supplemental information to diagnose each case because using one method doesn't provide sufficient accuracy. These conventional methods have depended on nervous responses, but Laser Doppler Flowmeter determines the pulp vitality by measuring pulpal blood flow. In this case, we tested the vitality of the traumatized teeth with incomplete root apices and autotransplanted teeth with conventional methods and Laser Doppler Flowmeter. Conventional methods, such as electric pulp test and cold test can produce various responses according to the development state of the pulpal nerve and the sensory threshold of the patient. But, Laser Doppler Flowmeter has a lower false response rate than any other pulp vitality test methods and it can determine the vitality somewhat earlier than the other method.

  • PDF