• Title/Summary/Keyword: DO meter

Search Result 192, Processing Time 0.027 seconds

Development of Inquiry-based Water Environmental Education Program using DO Meter - Measuring Activity of Dissolved Oxygen - (DO 미터를 이용한 탐구중심 물 환경교육 프로그램 개발 - 용존산소 측정 활동 -)

  • Lyu Jai-Hong;Lee Du-Gon
    • Hwankyungkyoyuk
    • /
    • v.19 no.2 s.30
    • /
    • pp.96-107
    • /
    • 2006
  • Inquiry has great value in environmental education(EE). Being able to see the world environmentally through 'inquiry-based environmental education' can be an important value and goal of EE. In this study, we intended to develop an EE program of measuring activity of dissolved oxygen(DO), based on the theory of 'inquiry-based EE'. Especially, we recognized the potential that DO meter can be used in 'inquiry-based EE', and we tried to develop a model of inquiry-based EE using DO meter. As a result of this research, we present specific models of inquiry-based EE about how to perform measuring activity of DO and how to use the DO meter in laboratories and streams from the perspective of inquiry of water environment. In the process of program development, we considered organization of the inquiry process, use of concept and knowledge, scientific inquiry and insightful inquiry, integration, sustain-ability, content components of 'Environmental Studies for EE', developmental level and in-forest of students. The developed EE model is a scientific inquiry model, pursuing 'explanation' based on data collection. Through this model, we tried to make students see water environment more deeply. The developed program can be applied to various water environments, like laboratories, streams, ponds, etc. It can be more effective inquiry activity if we perform measuring activities simultaneously with PH, electrical conductivity, and turbidity meters.

  • PDF

Color Design of Combination Meter in Passenger Car for Improving Readability (승용차 Combination Meter의 가독성 향상을 위한 색상 설계)

  • Kee, Do-Hyung
    • IE interfaces
    • /
    • v.11 no.2
    • /
    • pp.139-147
    • /
    • 1998
  • The purpose of this study is to survey colors of background, marker, and pointer being used in passenger car's combination meter, and to suggest ergonomic design guidelines of combination meter to enhance driver's readability. An experiment was conducted, in which colors of background, marker, and pointer were selected as independent variables, and reading time, reading error, and preference for combination meter were measured as dependent variables. Most of passenger cars sold in Korea were found to have combination meter with black background, while marker. The experimental results showed that reading time of combination meter with white background, black marker and point was shortest, reading error was lowest in combination meter with black background, yellow marker pointer, and preference for combination meter with white background, black marker and black or red pointer was highest. The results implied that combination meter with white background, black marker and black pointer should be used for comprehensively optimizing reading time, reading error, and preference for it. It was expected that these results could be used as valuable design guidelines when designing combination meter of passenger car.

  • PDF

Design and Fabrication of Portable Dissolved Oxygen Measurement System (휴대용 용존산소 측정 시스템의 설계 및 제작)

  • Chang, Choong-Won;Lee, Sung-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.219-223
    • /
    • 2008
  • The dissolved oxygen (DO) sensors were fabricated by screen printing method, and potable dissolved oxygen measurement system was fabricated for low cost products. The fabricated sensors had high current change and fast response according to dissolved oxygen concentrations in the applied voltage of 0.7 V. The DO measurement system was consisted of MCV, amplifier, filter, power supply and display. DO concentrations were programed to display as digital percentages by converting the analog value. It is expected that the fabricated DO measurement system can replace the expensive commercial DO meter, because it reveals the high accuracy of ${\pm}0.5%$ to the standard solution and the response time of about 100 sec like the commercial DO meter.

  • PDF

Driving Characteristics of Pneumatic Cylinder with Relief Valve Cushion Devices (릴리프밸브 쿠션기구 내장형 공기압 실린더의 구동 특성)

  • Kim, Do Tae
    • Journal of Drive and Control
    • /
    • v.13 no.4
    • /
    • pp.7-13
    • /
    • 2016
  • This paper presents the meter-out and meter-in speed control characteristics of a pneumatic cylinder with relief valve type cushion device. The piston displacement and velocity are measured to investigate high speed driving performance with variation of the pressure setting in relief valve, air supply pressure, load mass, the supply and exhaust flow rate from the cylinder. Also, the internal pressures and temperatures driving pressure and cushion chamber are measured. The piston displacements and velocities of meter-out and meter-in control are compared experimentally determined data. A comparison experimental data meter-out and meter-in control show that a relief valve type cushion device is suitable for high speed pneumatic cylinders. The desired response characteristics of piston displacement and velocity are satisfactory adjust the pressure setting of a relief valve with varying system parameters such as air supply pressure, load mass and controlled flow rate.

A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders (공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구)

  • Kim, Do-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.

Minimal Cut Set of Electric Power Installations using Fault Tree Analysis (FTA를 이용한 수변전설비의 최소절단집합 도출)

  • Park, Young-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

A study on the dynamics of a turbine-meter-type flowmeter for hydraulic systems

  • Yokota, Shinichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.60-65
    • /
    • 1994
  • In this study, the dynamic characteristics of a turbine-meter-type flowmeter is investigated by making use of the remote instantaneous flow rate measurement method (RIFM). The results of the frequency response test indicated that the gain of the flow rate of the turbine-meter-type flowmeter relative to the flow rate of the RIFM was nearly unity up to 40Hz and the phase lag of the flow rate became 90 degrees at 70Hz.

  • PDF

pH meter

  • O, Do-Seok
    • 월간산업보건
    • /
    • s.85
    • /
    • pp.25-31
    • /
    • 1995
  • PDF

The Telemedicine System based ECG Data using Bio-Signal Meter and Smart Device (생체신호 측정기와 스마트 디바이스를 활용한 심전도 데이터 기반의 원격진료 시스템)

  • Kim, Yi-Seul;Cho, Jinsoo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.51-56
    • /
    • 2012
  • In this paper, we propose a telemedicine system based ECG data using a bio-signal meter and a smart device for treating faraway patients. This system is composed of a patch-shaped portable bio-signal meter, patient's smart device application, and doctor's PC software. Using these components, doctors and patients can do telemedicine. First, a patient measures his own ECG signal with a bio-signal meter and send the data to a doctor using a smart device application. Then, the doctor checks the ECG data, and make and send a diagnosis chart to web server. Likewise, doctors and patients can be offered a medical environment without time and space restraints. Applying this system to real medical system can improve the problem of low accessibility and efficiency and also can reduce medical expenses.