• Title/Summary/Keyword: DINA model

Search Result 5, Processing Time 0.016 seconds

A Study on the Factors Affecting Examinee Classification Accuracy under DINA Model : Focused on Examinee Classification Methods (DINA 모형에서 응시생 분류 정확성에 영향을 미치는 요인 탐구 : 응시생 분류방법을 중심으로)

  • Kim, Ji-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3748-3759
    • /
    • 2013
  • The purpose of this study was to examine the classification accuracies of ML, MAP, and EAP methods under DINA model. For this purpose, this study examined the classification accuracies of the classification methods under the various conditions: the number of attributes, the ability distribution of examinees, and test length. To accomplish this purpose, this study used a simulation method. For the simulation study, data was simulated under the various simulation conditions including the number of attributes (K= 5, 7), the ability distribution of examinees (high, middle, low), and test length (J= 15, 30, 45). Additionally, the percent of agreements between true skill patterns(true ${\alpha}$) and skill patterns estimated by the ML, MAP, and EAP methods were calculated. The summary of the main results of this study is as follows: First, When the number of attributes was 5 and 7, the EAP method showed relatively higher average in the percent of exact agreement than the ML and MAP methods. Second, under the same conditions, as the number of attributes increased, the average percent of exact agreement decreased in ML, MAP, and EAP methods. Third, when the prior distribution of examinees ability was different from low to high under the conditions of the same test length, the EAP method showed relatively higher average in the percent of exact agreement than those of the ML and MAP methods. Fourth, the average percent of exact agreement increased in all methods, ML, MAP, and EAP when the test length increased from 15 to 30 and 45 under the conditions of the same the ability distribution of examinees.

Parametric inference on step-stress accelerated life testing for the extension of exponential distribution under progressive type-II censoring

  • El-Dina, M.M. Mohie;Abu-Youssef, S.E.;Ali, Nahed S.A.;Abd El-Raheem, A.M.
    • Communications for Statistical Applications and Methods
    • /
    • v.23 no.4
    • /
    • pp.269-285
    • /
    • 2016
  • In this paper, a simple step-stress accelerated life test (ALT) under progressive type-II censoring is considered. Progressive type-II censoring and accelerated life testing are provided to decrease the lifetime of testing and lower test expenses. The cumulative exposure model is assumed when the lifetime of test units follows an extension of the exponential distribution. Maximum likelihood estimates (MLEs) and Bayes estimates (BEs) of the model parameters are also obtained. In addition, a real dataset is analyzed to illustrate the proposed procedures. Approximate, bootstrap and credible confidence intervals (CIs) of the estimators are then derived. Finally, the accuracy of the MLEs and BEs for the model parameters is investigated through simulation studies.

Effect of Ion Pair on Thermostability of F1 Protease: Integration of Computational and Experimental Approaches

  • Rahman, Raja Noor Zaliha Raja Abd;Noor, Noor Dina Muhd;Ibrahim, Noor Azlina;Salleh, Abu Bakar;Basri, Mahiran
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.1
    • /
    • pp.34-45
    • /
    • 2012
  • A thermophilic Bacillus stearothermophilus F1 produces an extremely thermostable serine protease. The F1 protease sequence was used to predict its three-dimensional (3D) structure to provide better insights into the relationship between the protein structure and biological function and to identify opportunities for protein engineering. The final model was evaluated to ensure its accuracy using three independent methods: Procheck, Verify3D, and Errat. The predicted 3D structure of F1 protease was compared with the crystal structure of serine proteases from mesophilic bacteria and archaea, and led to the identification of features that were related to protein stabilization. Higher thermostability correlated with an increased number of residues that were involved in ion pairs or networks of ion pairs. Therefore, the mutants W200R and D58S were designed using site-directed mutagenesis to investigate F1 protease stability. The effects of addition and disruption of ion pair networks on the activity and various stabilities of mutant F1 proteases were compared with those of the wild-type F1 protease.

Convolutional neural networks for automated tooth numbering on panoramic radiographs: A scoping review

  • Ramadhan Hardani Putra;Eha Renwi Astuti;Aga Satria Nurrachman;Dina Karimah Putri;Ahmad Badruddin Ghazali;Tjio Andrinanti Pradini;Dhinda Tiara Prabaningtyas
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.271-281
    • /
    • 2023
  • Purpose: The objective of this scoping review was to investigate the applicability and performance of various convolutional neural network (CNN) models in tooth numbering on panoramic radiographs, achieved through classification, detection, and segmentation tasks. Materials and Methods: An online search was performed of the PubMed, Science Direct, and Scopus databases. Based on the selection process, 12 studies were included in this review. Results: Eleven studies utilized a CNN model for detection tasks, 5 for classification tasks, and 3 for segmentation tasks in the context of tooth numbering on panoramic radiographs. Most of these studies revealed high performance of various CNN models in automating tooth numbering. However, several studies also highlighted limitations of CNNs, such as the presence of false positives and false negatives in identifying decayed teeth, teeth with crown prosthetics, teeth adjacent to edentulous areas, dental implants, root remnants, wisdom teeth, and root canal-treated teeth. These limitations can be overcome by ensuring both the quality and quantity of datasets, as well as optimizing the CNN architecture. Conclusion: CNNs have demonstrated high performance in automated tooth numbering on panoramic radiographs. Future development of CNN-based models for this purpose should also consider different stages of dentition, such as the primary and mixed dentition stages, as well as the presence of various tooth conditions. Ultimately, an optimized CNN architecture can serve as the foundation for an automated tooth numbering system and for further artificial intelligence research on panoramic radiographs for a variety of purposes.

Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study

  • Dina Mohamed Ahmed Elawady;Wafaa Ibrahim Ibrahim;Radwa Gamal Ghanem;Reham Bassuni Osman
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.4
    • /
    • pp.201-211
    • /
    • 2024
  • PURPOSE. The aim of this prospective clinical study was to compare the influence of palatal vault forms on accuracy and speed of intraoral (IO) scans in completely edentulous cases. MATERIALS AND METHODS. Based on the palatal vault form, participants were divided into three equal groups (n = 10 each); Class I: moderate; Class II: deep; Class III: flat palatal vault. A reference model was created for each patient using polyvinylsiloxane impression material. The poured models were digitized using an extraoral scanner. The resultant data were imported as a solid CAD file into 3D analysis software (GOM Inspect 2018; Gom GmbH, Braunschweig, Germany) and aligned using the software's coordinate system to determine its X, Y, and Z axes. Five digital impressions (DIs) of maxilla were captured for each patient using an intraoral scanner (TRIOS; 3Shape A/S, Copenhagen, Denmark) and the resultant Standard Tessellation Language (STL) scan files served as test models. Trueness was evaluated by calculating arithmetic mean deviation (AMD) of the vault area between reference and test files while precision was evaluated by calculating AMD between captured scans to measure repeatability of scan acquisition. The scan time taken for each participant was also recorded. RESULTS. There was no significant difference in trueness and precision among the groups (P = .806 and .950, respectively). Average scan time for Class I and III palatal vaults was 1 min 13 seconds and 1 min 37 seconds, respectively, while class II deep palatal vaults showed the highest scan time of 5 mins. CONCLUSION. Palatal vault form in edentulous cases has an influence on scan time. However, it does not have a substantial impact on the accuracy of the acquired scans.