• Title/Summary/Keyword: DG18

Search Result 73, Processing Time 0.025 seconds

An Optimal Installation Strategy for Allocating Energy Storage Systems and Probabilistic-Based Distributed Generation in Active Distribution Networks

  • Sattarpour, Tohid;Tousi, Behrouz
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.350-358
    • /
    • 2017
  • Recently, owing to increased interest in low-carbon energy supplies, renewable energy sources such as photovoltaics and wind turbines in distribution networks have received considerable attention for generating clean and unlimited energy. The presence of energy storage systems (ESSs) in the promising field of active distribution networks (ADNs) would have direct impact on power system problems such as encountered in probabilistic distributed generation (DG) model studies. Hence, the optimal procedure is offered herein, in which the simultaneous placement of an ESS, photovoltaic-based DG, and wind turbine-based DG in an ADN is taken into account. The main goal of this paper is to maximize the net present value of the loss reduction benefit by considering the price of electricity for each load state. The proposed framework consists of a scenario tree method for covering the existing uncertainties in the distribution network's load demand as well as DG. The collected results verify the considerable effect of concurrent installation of probabilistic DG models and an ESS in defining the optimum site of DG and the ESS and they demonstrate that the optimum operation of an ESS in the ADN is consequently related to the highest value of the loss reduction benefit in long-term planning as well. The results obtained are encouraging.

Multi-Function Distributed Generation with Active Power Filter and Reactive Power Compensator

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1855-1865
    • /
    • 2018
  • This paper presents a control strategy for voltage-controlled multi-function distributed generation (DG) combined with an active power filter (APF) and a reactive power compensator. The control strategy is based on droop control. As a result of local nonlinear loads, the voltages of the point of common coupling (PCC) and the currents injecting into the grid by the DG are distorted. The power quality of the PCC voltage can be enhanced by using PCC harmonic compensation. In addition, with the PCC harmonic compensation, the DG offers a low-impedance path for harmonic currents. Therefore, the DG absorbs most of the harmonic currents generated by local loads, and the total harmonic distortion (THD) of the grid connected current is dramatically reduced. Furthermore, by regulating the reactive power of the DG, the magnitude of the PCC voltage can be maintained at its nominal value. The performance of the DG with the proposed control strategy is analyzed by bode diagrams. Finally, simulation and experimental results verify the proposed control strategy.

Simultaneous Planning of Renewable/ Non-Renewable Distributed Generation Units and Energy Storage Systems in Distribution Networks

  • Jannati, Jamil;Yazdaninejadi, Amin;Talavat, Vahid
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.111-118
    • /
    • 2017
  • The increased diversity of different types of energy sources requires moving towards smart distribution networks. This paper proposes a probabilistic DG (distributed generation) units planning model to determine technology type, capacity and location of DG units while simultaneously allocating ESS (energy storage systems) based on pre-determined capacities. This problem is studied in a wind integrated power system considering loads, prices and wind power generation uncertainties. A suitable method for DG unit planning will reduce costs and improve reliability concerns. Objective function is a cost function that minimizes DG investment and operational cost, purchased energy costs from upstream networks, the defined cost to reliability index, energy losses and the investment and degradation costs of ESS. Electrical load is a time variable and the model simulates a typical radial network successfully. The proposed model was solved using the DICOPT solver under GAMS optimization software.

A Bandstop Filter with Improved Slope Characteristics Using C-DGS(Coupled-Defected Ground Structure) (결합된 결함 접지면 구조(C-DGS)를 이용하여 향상된 차단 특성을 가지는 대역 저지 여파기)

  • Jung, Sang-Woon;Lim, Young-Kwang;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.834-838
    • /
    • 2007
  • A coupled-defected ground structure(C-DGS) having closely-located DGS cells is proposed for high performance bandstop filter applications. The negative coupling of ground currents between adjacent DGS cells greatly improves the stopband characteristics. We have measured the attenuation slope of 110.8 dB/GHz and -20 dB rejection band from 3.8 GHz to 15.5 GHz. Compared to the double-plane BSF, the proposed BSF improved the sharp cutoff response 7.6 times. We expect the C-DGS be helpful to improve the performance of DGS application circuits and also to extend the possible DGS applications.

An Unequal Wilkinson Power Divider Using Defected Ground Structure in Double Layered Substrate (이중 기판 결함 접지 구조를 이용한 비대칭 월킨슨 전력 분배기)

  • Lim, Jong-Sik;Koo, Jae-Jin;Oh, Seong-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1291-1298
    • /
    • 2007
  • A novel 1:4 unequal wilkinson power divider using rectangular-shaped defected ground structure(DGS) in double layered substrate is proposed for removing the ground problem of DGS in packaging. Rectangular-shared DGS produces the transmission line having much higher characteristic impedance than standard microstrip line. The proposed unequal divider is composed of DGS and double layered substrate in order to be free from the ground problem of DGS patterns in packaging in metal housings. The second substrate is attached to the first substrate which contains DGS pattern on its ground plane at the bottom side to form the double layered substrate. In order to show the validity of the proposed DGS in the double layered substrate, a 1:4 unequal power divider is designed and measured. The predicted and measured performances are shown with an excellent agreement between them.

The Reliability and Validity of the Digital Goniometer and Smart Phone to Determine Trunk Active Range of Motion in Stroke Patients

  • Park, Hee-yong;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.225-234
    • /
    • 2022
  • Background: Trunk movements are an important factor in activities of daily living; however, these movements can be impaired by stroke. It is difficult to quantify and measure the active range of motion (AROM) of the trunk in patients with stroke. Objects: To determine the reliability and validity of measurements using a digital goniometer (DG) and smart phone (SP) applications for trunk rotation and lateral flexion in stroke patients. Methods: This is an observational study, in which twenty participants were clinically diagnosed with stroke. Trunk rotation and lateral flexion AROM were assessed using the DG and SP applications (Compass and Clinometer). Intrarater reliability was determined using intraclass correlation coefficients (ICCs) with 95% confidence intervals. Pearson correlation coefficient was used to determine the validity of the DG and SP in AROM measurement. The level of agreement between the two instruments was shown by Bland-Altman plot and 95% limit of agreement (LoA) was calculated. Results: The intrarater reliability (rotation with DG: 0.96-0.98, SP: 0.98; lateral flexion with DG: 0.97-0.98, SP: 0.96) was excellent. A strong and significant correlation was found between DG and SP (rotation hemiplegic side: r = 0.95; non-hemiplegic side: r = 0.90; lateral flexion hemiplegic side: r = 0.88; non-hemiplegic side: r = 0.78). The level of agreement between the two instruments was rotation (hemiplegic side: 23.02° [LoA 17.41°, -5.61°]; non-hemiplegic side: 31.68° [LoA 23.87°, -7.81°]) and lateral flexion (hemiplegic side: 20.94° [LoA 17.48°, -3.46°]; non-hemiplegic side: 27.12° [LoA 18.44°, -8.68°]). Conclusion: Both DG and SP applications can be used as reliable methods for measuring trunk rotation and lateral flexion in patients with stroke. Although, considering the level of clinical agreement, DG and SP could not be used interchangeably for measurements.

Assessment of Airborne Fungi Concentrations in Subway Stations in Seoul, Korea (서울시 일부 지하철 역사 내 공기 중 진균 농도에 관한 연구)

  • Cho, Jun-Ho;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.478-485
    • /
    • 2009
  • This study was performed to assess airborne fungi concentrations during fall in eight subway stations in Seoul, Korea. The purpose of this study was to investigate appropriate culture media and evaluate factors affecting airborne fungi concentrations. Results indicated that airborne fungi concentrations showed log-normal distribution. Thus, geometric mean (GM) and geometric standard deviation (GSD) were calculated. The GM of airborne fungi concentrations cultured on malt extract agar (MEA) media was 466 $cfu/m^3$ (GSD 3.12; Range 113~4,172 $cfu/m^3$) and the GM of concentrations cultured on DG18 media was 242 $cfu/m^3$ (GSD 4.75; Range 49~6,093 $cfu/m^3$). Both of GM values exceeded 150 $cfu/m^3$, the guideline of World Health Organization (WHO). There was no significant difference between two fungi concentrations cultured on MEA and DG18 media, respectively. Two factors, such as relative humidity and depths of subway stations were significantly related to airborne fungi concentrations. It is recommended that special consideration should be given to deeper subway stations for improvement of indoor air quality.

Combined Treatment with 2-Deoxy-D-Glucose and Doxorubicin Enhances the in Vitro Efficiency of Breast Cancer Radiotherapy

  • Islamian, Jalil Pirayesh;Aghaee, Fahimeh;Farajollahi, Alireza;Baradaran, Behzad;Fazel, Mona
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8431-8438
    • /
    • 2016
  • Doxorubicin (DOX) was introduced as an effective chemotherapeutic for a wide range of cancers but with some severe side effects especially on myocardia. 2-Deoxy-D-glucose (2DG) enhances the damage caused by chemotherapeutics and ionizing radiation (IR) selectively in cancer cells. We have studied the effects of $1{\mu}M$ DOX and $500{\mu}M$ 2DG on radiation induced cell death, apoptosis and also on the expression levels of p53 and PTEN genes in T47D and SKBR3 breast cancer cells irradiated with 100, 150 and 200 cGy x-rays. DOX and 2DG treatments resulted in altered radiation-induced expression levels of p53 and PTEN genes in T47D as well as SKBR3 cells. In addition, the combination along with IR decreased the viability of both cell lines. The radiobiological parameter (D0) of T47D cells treated with 2DG/DOX and IR was 140 cGy compared to 160 cGy obtained with IR alone. The same parameters for SKBR3 cell lines were calculated as 120 and 140 cGy, respectively. The sensitivity enhancement ratios (SERs) for the combined chemo-radiotherapy on T47D and SKBR3 cell lines were 1.14 and 1.16, respectively. According to the obtained results, the combination treatment may use as an effective targeted treatment of breast cancer either by reducing the single modality treatment side effects.

Study on sampling methods for mold from indoor air in domestic environment (국내 환경에서 실내 부유진균 포집 방법 연구)

  • Ahn, Geum Ran;Kim, Bo Young;Kim, Ji Eun;Son, Bu Sun;Park, Moo-Kyun;Kim, Sung-Yeon;Kwon, Myung-Hee;Kim, Seong Hwan
    • Journal of odor and indoor environment
    • /
    • v.16 no.1
    • /
    • pp.47-53
    • /
    • 2017
  • Mold is one of the important bio-aerosols affecting human health in the indoor environment. To manage mold contamination, it is necessary to use an appropriate method for its detection and enumeration. Recently, the impaction method of ISO 16000-18 has been established as one of methods to detect and enumerate molds in air. To investigate the general use of the impaction method for mold detection in domestic indoor environments, the suitability of the method was assessed using different antibiotics, media and air samplers. All of the three antibiotics tested - ampicillin, chloramphenicol and streptomycin - showed inhibitory effects on bacterial colony formation on MEA and DG-18 media, without inhibiting mold growth. Of these three antibiotics, ampicillin was the most effective. There was no statistical difference between MEA and DG-18 media in the measurement of mold concentration. The formation of discriminative colony morphology was more apparent in DG-18 media. No significant difference in the measurement of mold concentration was found between Andersen samplers and MAS-100NT samplers, which are two major samplers introduced in Korea.

A Study on Islanding Detection of Distributed Generation Considering Fault Location (사고위치를 고려한 분산전원의 단독운전 상태 검출에 관한 연구)

  • 정승복;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.118-123
    • /
    • 2004
  • This paper studies islanding detection of DG(distributed generation) considering fault location. Through the past studies, we found that islanding detection has been studied that DG disconnected when power islanding was detected by power state change and output change of DG. But, fault location was not considered. For example, fault in adjacent distribution line, fault on interconnection line fault, load shave by overload and normal operation were not considered. In this paper, We distinguish these considerations through power state change. Also, we proved islanding detection algorithm through PSCAD/EMTDC simulation.