• Title/Summary/Keyword: DETERIORATION TYPE

Search Result 511, Processing Time 0.028 seconds

Development of Dipstick-Gage-Type Small Sensor Equipped with Individual Control Circuit for Detecting Engine Oil Deterioration (전용제어회로를 적용한 딥스틱게이지형 소형 엔진열화감지센서 개발)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.143-148
    • /
    • 2013
  • In this study, several sensor parts used to obtain better signal stability are designed, a separate control circuit for the sensor is developed, and the results obtained using this control circuit are analyzed. The capacitances of the whole sensor system are measured using the control circuit connected to an improved flexible printed circuit board and an asymmetric dual sensor coated with a ceramic material. To realize good discrimination for a small change in the measured capacitance as the engine oil deteriorates, a commercial application-specific integrated circuit is installed on the control circuit as a capacitance-to-digital converter. The absolute error of a measured signal is found to be approximately ${\pm}4fF$.

Water Quality Modeling of the Eutrophic Transition Zone in a River-Type Reservoir Paldang (부영양화된 하천형 호소(팔당호) 전이대의 수질모델링)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • This study was conducted to investigate the main cause of water quality deterioration during the spring season in the transition zone between the South Han River and the river-reservoir Paldang. A water quality model modified from QUAL2E (U.S.EPA) was used, and the model showed that eutrophication and algal production in the low flow season affected about 60% of the organic pollution at the downstream of the South Han River. This result means that phosphorus control is prior to external organic material management to ameliorate the deterioration of water quality in the water body.

Effects of Curing Agent Content and Post-curing Conditions on Dielectric Deterioration Characteristics of DGEBA/MDA/SN System (경화제 함량과 후기경화조건에 따른 DGEBA/MDA/SN계의 절연열화 특성)

  • 조영신;박수길;임기조;심미자;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.313-316
    • /
    • 1997
  • The effects of aromatic curing agent of MDA contents and post curing conditions on dielectric deterioration characteristics of DGEBA/MDA/SN system were investigated. The dielectric properties were measured by using needle-plane electrode geometry under the commercial AC high electric field application. As the curing agent content increased, the dielectric breakdown strength increased and then decreased slightly. All the trees initiated from the tip of needle electrode and the shape of the tree in this system was a dendrite type.

  • PDF

Corrosion Monitoring Technology of Rebar in Reinforced Concrete Structures (철근콘크리트 구조물의 철근부식 모니터링 기술)

  • Kwon, Seong-Junn;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.258-259
    • /
    • 2019
  • Corrosion of rebar in RC structures, which results in premature deterioration of reinforced concrete structures, is a very serious problem. Most corrosion monitoring and sensing technologies require some type of wired or wireless connection between the sensor and monitoring electronics. This causes significant problems in their installation and long-term use. In this paper we describe a corrosion monitoring technology of rebar in reinforced concrete structures. Especially, it is emphasize that the development of sensors and monitoring system not only occurrence of rebar corrosion but also penetration of deterioration factor such like chloride ion and carbon dioxite etc..

  • PDF

Study on the Physical Properties and Characteristics of Adhesives for Woodcraft (목공예용 천연 및 합성 접착제의 특성 연구)

  • Kim, Seong Eun;Lee, Jin Kyung;Lee, Chae Hoon;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.681-688
    • /
    • 2019
  • In this study, the characteristics of natural and synthetic adhesives used in woodcraft were evaluated. The pattern of deterioration of wood and adhesives according to changes in temperature and humidity were compared. For materials, one type of anlmal glue, three kinds of polyvinyl acetate adhesives, one type of epoxy adhesive and one type of zelkova wood were selected. Characteristics of physical and chemical characteristics, weather resistance and drying speed assessment were carried out. The adhesion characteristic evaluation showed that the adhesion strength of anlmal glue and one type of polyvinyl acetate adhesive were 6.54 N/㎟ and 7.01 N/㎟, pH meter of anlmal glue and polyvinyl acetate adhesives was pH 7.03 and pH 3.32-3.59 which were range of available as an adhesive. According to the test results of weather resistance, epoxy adhesives had the highest decreasing value in adhesion strength after deterioration. In the reversible test of the adhesive, it was found to be highly reversible in NaOH, a soluble solvent excluding epoxy, but attention is required when using the wood since it may show discoloration during processing.

The Estimation of Durability Factor of Deteriorated Jointed Concrete Pavement Using Image Analysis Test (화상분석 실험을 이용한 열화된 줄눈콘크리트 포장의 내구성 지수 평가)

  • Choi, Pan-Gil;Kim, Yong-Gon;Yun, Kyong-Ku;Kwon, Soo-Ahn
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.31-38
    • /
    • 2009
  • The primary objective of this study was to estimate the deterioration degree of jointed concrete pavement which was major concrete pavement type in Korea. First of all, visual survey of concrete pavement was performed to observe deterioration types. In the result of visual survey, the majority of concrete pavement deterioration was investigated in joint area. It is appeared that most of the distresses are durability cracking and joint distress. Second, concrete core specimens were taken from eight locations including good section (4 locations) and bad section (4 locations) based on visual survey. The deterioration reasons of concrete pavement were analyzed with ultrasonic pulse velocity test, splitting tensile strength test, and image analysis for concrete core specimens. Among the image analysis test result for 21 concrete core specimens, only two specimens satisfied the Kansas DOT criteria of spacing factor, $250\;{\mu}m$, and the remains of 19 specimens were estimated to be above $250\;{\mu}m$. The durability factor of concrete was estimated very low. As a result, it was analyzed that the main deterioration reason of the deteriorated jointed concrete pavement was to be freezing and thawing damages.

The Performance Evaluation Analysis of PV System for Arch and Flat-Plate Type (평판형 및 아치형 태양광발전 시스템의 성능평가 분석)

  • Piao, Zheng-Guo;Choi, Youn-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1012-1018
    • /
    • 2015
  • The studies on the operating performance analysis or design about the fixed tilt angle flat-plate photovoltaic (PV) system are still lively going off. However the operating property analysis about the arch type PV system which means PV array were designed as round type is dissatisfied. In this paper, we theoretically established the factors which are cause of the deterioration in performance of arch type PV system. In addition, we use the Solar Pro simulation tools to design both flat-plate type and arch type 30kW PV systems. The simulations about arch type PV system applied two ways such as central inverter and string inverter were conducted. The performance ratio (PR) of the PV system with flat-plate type shows the highest value 74[%] when the tilt angle is 30°. In case of arch type, when applying central inverter method, PR value shows approximately 73[%] and no more difference with arch type of the PV array. This value shows 1[%] decrease compare with the flat-plate type. However when applying string inverter methods, the average PR value shows 80 % and 6% improved than the central inverter method.

A Study on the Varistor Maintenance program in urban rail chopper type subway train (도시철도 쵸파형 전동차 배리스터(varistor) 유지보수 방안 연구)

  • Woo, Jong-Hyuk;Lee, Jong-In;Lee, Yong-Gi;Song, Jeong-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1647-1653
    • /
    • 2011
  • In the case of an urban rail chopper type subway train, varistors have been installed for protecting usual electronic equipments, semiconductor devices(diodes, transistors, thyrister, etc.) communications, measuring, control device and absorbing opening & closing surge of electromagnetic valve. These varistors were steadily reduced dielectric strength as becoming superannuated. Thus there is a problem that reacts more sensitive at the same surge in the general control operation. On existing maintenance, there is not specific standard to replace superannuated varistor. So when maintaining chopper type subway train, all varistors or old varistors that workers checked a discoloration & crack with the naked eye and noticed degradation smell by deterioration are replaced. This study suggests detail standards for judgement that varistors are good or bad chopper type subway train, and it draw a efficient maintenance which efficient maintenance can check more easy the degradation properties variation.

  • PDF

A Study on the Deteriorations Mechanism of Timeworn Buildings in Seoul (대도시 지역의 노후 건축물의 노후 성상에 관한 연구)

  • Kwon, Ki-Hyuk;Lee, Kyoung-Yong;Yang, Hee-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.87-95
    • /
    • 2002
  • Because of the gravitation of population toward large cities, a number of buildings have been constructed since 1970's. They have been rapidly deteriorated as time passed by. Therefore the purpose of this paper is to present basic data on private buildings managed by the Seoul Metropolitan Government and to analyse deterioration factors of them as well as interrelation. And then, the results of this paper can be used to establish the policy of managing timeworn buildings. Through this study timeworn masonry buildings occupy the major part of timeworn buildings, which have almost structural instability, especially individual residence. Both structure type and building type have an interrelation with the deterioration grade. The structure grade have an interrelation with occupancy class more than structure type.

Detailed Deterioration Diagnosis and Analysis of Site Environment for the Taean Dongmunri Maaesamjonbulipsang (Rock-carved Standing Triad Buddha Statue), Korea (태안 동문리 마애삼존불입상의 정밀 훼손도 진단과 위치환경 분석)

  • Lee, Sun-Myung;Jun, Byung-Kyu;Shin, Eun-Jeong;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.381-393
    • /
    • 2011
  • This study focus on the surface deterioration diagnosis based on the material characteristics of Taean Dongmunri Maaesamjonbulipsang(rock-carved standing triad Buddha Statue) and the weathering environment analysis. Rock materials of the triad Buddha is coarse-grained biotite granite which is composed mainly of quartz, K-feldspar, plagioclase, biotite and muscovite. The triad Buddha was serious surface irregularity(13.5%), exfoliation(12.3%) and discoloration(46.6%), and the physical characteristics using ultrasonic velocity appeared fourth grade (0.59, highly weathered). Korean style wooden shelter of the triad Buddha(closed type) maintained high humidity environment (daily mean; 86.6%) than exterior environment, and appeared the possibility of deterioration by freezing-thawing because the temperature showed below zero temperatures in winter. The shelter was changed from closed-type to open-type to relieve the moisture problem recently. But the moisture problem is yet to be solved because surface water flowing along northern wayside is flowed into triad Buddha. Therefore, environmental control will need to stop inflow of water into triad Buddha.