Abstract
Because of the gravitation of population toward large cities, a number of buildings have been constructed since 1970's. They have been rapidly deteriorated as time passed by. Therefore the purpose of this paper is to present basic data on private buildings managed by the Seoul Metropolitan Government and to analyse deterioration factors of them as well as interrelation. And then, the results of this paper can be used to establish the policy of managing timeworn buildings. Through this study timeworn masonry buildings occupy the major part of timeworn buildings, which have almost structural instability, especially individual residence. Both structure type and building type have an interrelation with the deterioration grade. The structure grade have an interrelation with occupancy class more than structure type.
Keywords
Citations & Related Records
연도 인용수 순위
  • Reference
1 권기혁, ‘철근콘크리트조 교육시설물의 열화 성 상에 관한 조사 연구', 한국교육시설학회지, 제4권 3호 1997, pp5-ppI4
2 '鐵筋ユンクリート 建物のひびわれと對策'. ワンポイント, 建築技術
3 '민간 건축물 안전점검'., 2001, 서울시립대학교
4 '建築安全論'. 新建築學大系
5 Harry A Harris, editor, 'Masom$\gamma$: Materials, Design, Construction, & Maintenance', STP 992
6 Basic Procedures Manual, 'Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings' , Federal Emergency Management Agency, FEMA 306/May 1999
7 '建築物の調査. 劣化診斷. 修藉の考え方(案) 同解說.' 日本建築學會
8 권기혁, '서울시 조적조 건물의 실태와 내진 성능 강화 기법', 서울국제학술심포지움, 서울특별 시, vol, sec3. 2000, p196-p211
9 김정수외 5인, '건축일반구조학', 문운당.
10 John M. Melander and Lynn R. Lauersdorf, eitors, 'Masonry : Design and Construction, Problems and Repair' STP 1180
11 대한건축학회, '건축물의 안전진단과 보수 보강' 1993년
12 飯域裕, '建築維持保全', 丸善妹式會社
13 '조적조 건축물에 대한 내전 보강 방안,' 2001, 서울특별시