• Title/Summary/Keyword: DCR

Search Result 86, Processing Time 0.032 seconds

Performance of Direct-Conversion Receiver with AC-Coupling in DC-Offset interference environment (DC-Offset 간섭환경에서 AC-Coupling을 갖는 직접변환 수신기의 성능)

  • 성봉훈;송윤정;김영완;김내수;서종수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.9-14
    • /
    • 2002
  • Direct-conversion receiver(DCR) architecture has superior advantages in size, cost, and power over superheterodyne receiver architectures. However, the use of direct-conversion receiver architecture has been limited due to the direct-current offset noise. The ac coupling, which is used to overcome the direct-current offset noise, causes an inter-symbol interference(ISI), whose effects can be effectively mitigated using an equalizer. In this paper, the performance of a direct-conversion receiver with ac coupling in the presence of direct-current offset is analyzed via computer simulation. The simulation result shows that by using decision feedback equalizer with LMS(Least Mean Square) algorithm, signal-to-noise ratio loss of the direct-conversion receiver compared to the idea receiver can be reduced to less than 1㏈ for corner frequencies as large as 10% of the symbol rate.

  • PDF

A Numerical Study of Supersonic Combustion of Gas Generator (Gas generator의 초음속 연소현상에 대한 연구)

  • Kim, Seong-Jin;Seo, Bong-Gyun;Yeom, Hyo-Won;Sung, Hong-Gye;Gil, Hyun-Yong;Yoon, Hyun-Gull
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.419-422
    • /
    • 2010
  • An unsteady numerical combustion analysis was performed to investigate the combustion characteristics of A Dual Combustion Ramjet(DCR) engine using a gas generator. According to a variance of the equivalence ratio of the gas generator, the flow pattern in the combustor was analyzed. A typical acoustic frequency in the combustor was observed by detail analysis of pressure fluctuation at each location of the combustor.

  • PDF

Numerical Study of Flame Stability of Turbulent Combustion in a Dual Combustion Ramjet (이중연소 램제트 엔진의 난류 연소 현상과 화염 안정성)

  • Choi, Jeong-Yeol;Han, Sang-Hoon;Kim, Kyu-Hong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.371-374
    • /
    • 2011
  • High-resolution numerical study is carried out to investigate the flame stability of the turbulent supersonic combustion in a Dual-Combustion Ramjet (DCR). The auto-ignition in a shear layer between hydrogen/carbon-monoxide syngas and air was studied at elevated enthalpy condition. Comparison of a constant area combustor and a combustor with a small divergence angle shows that the supersonic combustion has a characteristics of the lifted flame and its stability is influenced significantly by the compressibility.

  • PDF

Supersonic Combustion Experiments of Dual Combustors (이중 연소기의 초음속 연소 실험)

  • Byun, Jong-Ryul;Lee, Sang-Yeon;Moon, Kwan-Ho;Hwang, Ki-Young;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.386-387
    • /
    • 2012
  • This experimental study is the supersonic combustion of dual combustors in dual combustion ramjet engine. Through the preliminary performance analysis of DCR, the configuration of dual combustors was determined and constructed, supersonic experiments were accomplished.

  • PDF

CT Simulation Technique for Craniospinal Irradiation in Supine Position (전산화단층촬영모의치료장치를 이용한 배와위 두개척수 방사선치료 계획)

  • Lee, Suk;Kim, Yong-Bae;Kwon, Soo-Il;Chu, Sung-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • Purpose : In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. Materials and Method : A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetrie image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was peformed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. Results : CSI in the supine position was successfully peformed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The differences between the DRRs and the portal films were less than 3 mm in the vertebral contour. Conclusion : CSI in the supine position is feasible in patients who cannot lie on prone position, such as pediatric patienta under the age of 4 years, patients with a poor general condition, or patients with a tracheostomy.

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

Trends in Colorectal Cancer Incidence in Daejeon and Chungcheongnam-do, South Korea (2000-2012) (대전광역시와 충청남도의 13년간(2000-2012) 대장암 발생 추세)

  • Kim, Soon-Young;Kweon, In-Sun;Kim, Jung-A;Lee, Tae-Yong;Nam, Hae-Sung
    • Journal of agricultural medicine and community health
    • /
    • v.40 no.3
    • /
    • pp.115-125
    • /
    • 2015
  • Objectives: Colorectal cancer is one of the major cancers in South Korea. We described the time trends in colorectal cancer incidence in Daejeon, a metropolitan city, and Chungcheongnam-do (Chungnam), a rural province, South Korea. Methods: Using the databases from the Daejeon Cancer Registry (DCR) and the Chungnam Cancer Registry (CCR), age-standardized (to world standard population) rates for incidence (ASRW) were calculated. Average annual percent change (AAPC) was assessed as a trend indicator. The completeness (such as the mortality/incidence ratio) and validity (such as the death certificate only %, microscopic verification %, primary site uncertain %, and age unknown %) were analyzed to examine the data quality of DCR and CCR. Results: Incidence of colorectal cancer showed increasing trend in both sexes. Over the years 2000-2012 in Daejeon, ASRW was increased significantly from 37.2 to 51.7 per 100,000 person-years (AAPC, 3.9%) among men and from 17.1 to 28.4 (AAPC, 3.9%) among women, respectively. In Chungnam, ASRW was also increased from 29.8 to 50.1 per 100,000 person-years (AAPC, 5.1%) among men and from 15.9 to 26.6 (AAPC, 3.2%) among women, respectively. The AAPC for colon cancer was greater than rectal cancer in both Daejeon and Chungnam. The trend of rectal cancer incidence was differ by sex (AAPC in men vs women, 2.7% vs 1.7% in Daejeon; 3.5% vs 0.8% in Chungnam). Indices of completeness and validity showed that the quality control of DCR and CCR was adequate to describe the trends of ASRW. Conclusions: Both Daejeon and Chungnam have had a rapid increase in colorectal cancer incidence. Monitoring and intervention are required on the risk factors which may contribute to this trend.

Evaluation for Progressive Collapse Resistance of a RC Flat Plate System Using the Static and Dynamic Analysis (정적 및 동적 해석을 통한 철근콘크리트 무량판 구조의 연쇄 붕괴 저항 성능 평가)

  • Lee, Seon-Woong;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.245-252
    • /
    • 2011
  • Currently, the design guidelines for the prevention of progressive collapse are not available in Korea due to the lack of study efforts in progressive collapse resistance evaluation of RC flat plate system. Therefore, in this study, three types of analysis were conducted to evaluate the progressive collapse resistance of a RC flat plate system. A linear static analysis was carried out by comparing the demand-capacity ratio (DCR) differences of the systems using the alternate load path method, which is the guideline of GSA. A dynamic behavior was investigated by checking the vertical deflection after removal of the column using the linear dynamic analysis. Lastly, a maximum load factor was investigated using the nonlinear static analysis. The finite element (FE) analyses were conducted using various parameters to analyze the results obtained using effective beam width (EB) model and plate element FEM (PF) model. This study results showed that the strength contributions of the slab in the EB models are underestimated compared to those obtained from the PF models. Therefore, a detailed FE analysis considering the slab element is required to thoroughly estimate the progressive collapse resisting capacity of flat plate system. The scenario of the corner column (CC) removal is the most dangerous conditions where as the scenario of the inner column (IC) removal is the least dangerous conditions based on the consideration of various parameters. The analysis results will allow more realistic evaluations of progressive collapse resistance of RC flat plate system.

Clinical Observation on Recombinant Human Endostatin Combined with Chemotherapy for Advanced Gastrointestinal Cancer

  • Gao, Shao-Rong;Li, Lu-Ming;Xia, Hai-Ping;Wang, Guang-Ming;Xu, Hong-Yan;Wang, Ai-Rong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.4037-4040
    • /
    • 2015
  • Objective: To explore the clinical efficacy and toxic and side effects of recombinant human endostatin (rhendostatin/endostar) combined with chemotherapy in the treatment of advanced gastric cancer. Materials and Methods: A total of 70 patients with advanced gastrointestinal adenocarcioma confirmed by histopathology and/or cytological examination were divided into group A (37 patients) and group B (33 patients). Patients in group A were given intravenous drip of 15 mg endostar added into 500 mL normal saline, once every other day until the cessation of chemotherapy or patients' maximal tolerance to chemotherapy. Patients in group B received chemotherapy alone. Two groups selected the same chemotherapy regimens. FOLFIRI scheme: 90-min intravenous drip of $180mg/m^2$ irinotecan, intravenous drip of $200mg/m^2$ calcium folinate (CF) and $400mg/m^2$ 5-fluorouracil (5-Fu) on d1, and continuous intravenous pumping of 2 $400mg/m^2$ 5-Fu for 46 h. FOLFOX4 scheme: intravenous injection of $85mg/m^2$ oxaliplatin (L-OHP), $200mg/m^2$ calcium folinate (CF) and $400mg/m^2$ 5-FU on d1 for 2 h, and then continuous intravenous pumping of 2 $400mg/m^2$ 5-Fu for 46 h. XELOX scheme: oral administration of 1 $500mg/m^2$ xeloda (or tegafur 50~60 mg) in twice during d1~14 and intravenous drip of $135mg/m^2$ L-OHP on d1 for 2 h. The modified FOLFOX scheme: intravenous injection of $135mg/m^2$ L-OHP on d1 for 2 h, $200mg/m^2$ CF and 1.0 g tegafur during d1~5. Whereas, control Group B received chemotherapy regimens which were same as Group A, but no addition of endostar. Before chemotherapy, patients were given intravenous injection of 8 mg ondansetron, intramuscular injection of 10 mg metoclopramide and 20 mg diphenhydramine for prevention of vomiting, protection of liver and stomach as well as symptomatic supportive treatment. One cycle was 21 d, 4~6 cycles in total. The efficacy was evaluated every 2 cycles. Results: 32 patients in Group A could be evaluated, and the response rate (RR) and disease control rate (DCR) were 59.38% and 78.13%, respectively. 31 patients in Groups could be evaluated, and the RR and DCR were 32.26% and 54.84%, respectively. The differences between 2 groups were significant. The toxic effects include myelosuppression, gastrointestinal reaction, fatigue, cardiotoxicity and peripheral neurotoxicity. Conclusions: Preliminary observations show that endostar (once every other day) combined with chemotherapy is effective in the treatment of advanced gastrointestinal cancer, with low toxic effects, good tolerance, deserving further study.

Efficacy of Taxane-Based Regimens in a First-line Setting for Recurrent and/or Metastatic Chinese Patients with Esophageal Cancer

  • Jiang, Chang;Liao, Fang-Xin;Rong, Yu-Ming;Yang, Qiong;Yin, Chen-Xi;He, Wen-Zhuo;Cai, Xiu-Yu;Guo, Gui-Fang;Qiu, Hui-Juan;Chen, Xu-Xian;Zhang, Bei;Xia, Liang-Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5493-5498
    • /
    • 2014
  • Objective: To compare the efficacy of taxane-based regimens in the first line setting retrospectively in Chinese patients with recurrent and/or metastatic esophageal cancer. Methods: We analyzed 102 recurrent and/or metastatic esophageal cancer patients who received taxanes-based regimens in a first-line setting from January 2009 to December 2013. Sixteen (15.7%) patients were administered Nab-PTX based chemotherapy and 86 patients (84.3%) received paclitaxel (PTX) or docetaxel (DTX) based chemotherapy. Patients in the PTX/DTX group could be further divided into TP (71 patients) and TPF (15 patients) groups. Results: The objective response rate (ORR) of all patients was 20.6%, and the disease control rate (DCR) was 67.6%. The median overall survival (OS) was 10.5 months (95% CI 10.1-16.4) and the median progression-free survival (PFS) was 6.04 months (95% CI 5.09-7.91). The DCR was higher in the TPF group than the TP group (93.3% vs. 59.1%; p = 0.015 ). There were no significant differences in ORR, OS, and PFS among Nab-PTX, TPF and TP groups. Conclusions: The three regimens of Nab-PTX based, TP and TPF proved active in a first line setting of Chinese patients with recurrent and/or metastatic esophageal cancer, and should thus be regarded as alternative treatments.