• Title/Summary/Keyword: DC23

Search Result 395, Processing Time 0.02 seconds

A study on the low power architecture of multi-giga bit synchronous DRAM's (Giga Bit급 저전력 synchronous DRAM 구조에 대한 연구)

  • 유회준;이정우
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.11
    • /
    • pp.1-11
    • /
    • 1997
  • The transient current components of the dRAM are analyzed and the sensing current, data path operation current and DC leakage current are revealed to be the major curretn components. It is expected that the supply voltage of less than 1.5V with low VT MOS witll be used in multi-giga bit dRAM. A low voltage dual VT self-timed CMOS logic in which the subthreshold leakage current path is blocked by a large high-VT MOS is proposed. An active signal at each node of the nature speeds up the signal propagation and enables the synchronous DRAM to adopt a fast pipelining scheme. The sensing current can be reduced by adopting 8 bit prefetch scheme with 1.2V VDD. Although the total cycle time for the sequential 8 bit read is the same as that of the 3.3V conventional DRAM, the sensing current is loered to 0.7mA or less than 2.3% of the current of 3.3V conventional DRAM. 4 stage pipeline scheme is used to rduce the power consumption in the 4 giga bit DRAM data path of which length and RC delay amount to 3 cm and 23.3ns, respectively. A simple wave pipeline scheme is used in the data path where 4 sequential data pulses of 5 ns width are concurrently transferred. With the reduction of the supply voltage from 3.3V to 1.2V, the operation current is lowered from 22mA to 2.5mA while the operation speed is enhanced more than 4 times with 6 ns cycle time.

  • PDF

Comparison of bodice prototypes of adolescent male students using 3D virtual simulation program (3D 가상착의 프로그램을 활용한 청소년 남학생의 보디스 원형 비교)

  • Cha, Su-Joung
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.5
    • /
    • pp.727-743
    • /
    • 2018
  • In this study, we used the 3D simulation program to create bodice patterns for adolescents boy students and analyze the fitting and air gap through 3D simulation. The purpose of this study was to select the bodice pattern method that best suited the body shapes of the adolescents male students. The subjects of this study were the French E pattern, Japanese N pattern, and Korean industrial L and J patterns. The applied size was the sixth Korean human body size survey data of 2010 Korea. The age range of the subjects was 13-18 years. DC Suite Program Ver. 5.1 was used, and SPSS 23.0 program was used for data analysis. As a result of comparing the shapes of the bodice patterns in the 3D simulation program, the E pattern had two waist darts on the front and one shoulder dart and one waist dart on the back, and the J and L patterns only had one dart on the back. The N pattern had no darts on either the front or back. As a result of examining the appearance evaluation of the pattern, air gap, color distribution, and clothing cross-section, the E pattern was evaluated as the closest to the body, and the N pattern was evaluated as the pattern with the largest allowance. The J pattern was evaluated as the best fit for body shape of the male adolescents. However, it is necessary to develop a pattern system by adding extra ease in setting the center front length.

Theoretical considerations on the giant magnetoimpedance effect in amorphous ribbons

  • Phan, Manh-Huong;Nguyen Cuong;Yu, Seong-Cho
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.60-61
    • /
    • 2003
  • Theoretical considerations on a giant magneto-impedance (GMI) effect in amorphous ribbons (i.e., thin films) have been made in terms of the expressions of effective permeability and impedance derived in the frame of classical electrodynamics and ferromagnetism. The dependence of GMI effect on the external do magnetic field (H$\_$ext/) and the frequency of alternating current are simulated and discussed in the knowledge of energy conversion consisting of the current energy loss, the ferromagnetic energy consumption, and the magnetic energy storage in the film. The obtained results are summarized as follow: (a) As frequency f< 20 ㎒, the real part of effective permeability (${\mu}$′) changes slightly. The peak of the ${\mu}$′curve always locates at H$\_$ext/=H$\_$ani/ - the anisotropy field. However, the peak value of ${\mu}$′ tends to increase with increasing frequency in the frequency range of 11-20 ㎒. (b) In the frequency range, f= 21-23 ㎒, a negative peak additionally appears. Meanwhile, both the positive and negative peak values rapidly increase with increasing frequency and their peak positions shift towards a high H$\_$ext/. (c) The positive peak value of ${\mu}$′ starts to decrease at f= 29 ㎒ and its negative peak does so at about 35 ㎒. Then, both peaks keep such a tendency and their peak positions move to high H$\_$ext/, as increasing frequency. (d) The dependence of the imaginary part of effective permeability (${\mu}$") on the external dc magnetic field and the frequency of the alternating field indicates that there is only one peak involved in ${\mu}$" for the whole frequency range. (e) The impedance vs. magnetic field curves at various frequencies show that there is a critical value of frequency around f= 18-19 ㎒ where the transition between two frequency regimes occurs; the one (low frequency) in which ${\mu}$′ predominantly contributes to the GMI effect and the other (high frequency) in which ${\mu}$" determines the GMI effect.

  • PDF

Influence of Ag Thickness on the Properties of TiO2/Ag/TiO2 Trilayer Films (Ag 중간층 두께에 따른 TiO2/Ag/TiO2 박막의 광학적 특성 변화)

  • Kim, So-Young;Jeon, Jae-Hyun;Gong, Tae-Kyung;Kim, Sun-Kyung;Choi, Dong-Hyuk;Son, Dong-Il;Kim, Daeil
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • $TiO_2/Ag/TiO_2$ trilayer films were deposited with radio frequency (RF) and direct current (DC) magnetron sputtering onto the glass substrate to consider the influence of Ag interlayer on the optical properties of the films. The thickness of $TiO_2$ films was kept at 24 nm, while the thickness of Ag interlayer was varied as 5, 10, 15, and 20 nm. As-deposited $TiO_2$ single layer films show the optical transmittance of 66.7% in the visible wave-length region and the optical reflectance of 16.5%, while the $TiO_2$ films with a 15 nm thick Ag interlayer show the enhanced optical transmittance of 80.2% and optical reflectance of 77.8%. The carrier concentration was also influenced by Ag interlayer. The highest carrier concentration of $1.01{\times}10^{23}cm^{-3}$ was observed for a 15 nm thick Ag interlayer in $TiO_2/Ag/TiO_2$ films. The observed result means that an optimized Ag interlayer in $TiO_2/Ag/TiO_2$ films enhanced the structural and optical properties of the films.

Effects of Electroacupuncture on the Modulation of Formalin-induced Pain in the Rat (흰쥐 족저에 Formalin 주입으로 유발된 통증반응에 대한 전침 효과)

  • 김재효;최동옥;김민선;박병림;손인철
    • The Journal of Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.97-107
    • /
    • 2002
  • Objective : Acupuncture is a method used to treat many kinds of pain in oriental cultural medicine. Especially when hetero-segmental area acu-points are stimulated, the therapeutic effects of pain control have more critical properties than other methods of acupuncture. However, the mechanism of pain control by acupuncture is contradictory so far. The present study examined the effects of electroacupuncture (EA) applied to the acu-point of the hetero-segmental area on modulation of formalin-induced pain in Sprague-Dawley rats. Methods : In order to apply EA to acu-points in the plantar area of right forepaws, a pair of Teflon-coated stainless steel wires were implanted in HT 7 (Shin-Moon) and PC 7 (Dae-Reung) 7 days before the behavioral test. A behavioral test was performed by means of video camera after injection of 5% formalin ($50{\;}\mu\textrm{l}$) into the lateral plantar region of the left hind paw. EA was delivered by a constant DC current stimulator at 4~5 mA, 2 ms, and 10 Hz for 30 min. c-Fos protein expression was measured in the lumbar spinal cord at 2 hr and 4 hr after formalin injection. Results : Behavioral responses including favoring, flinching and biting occurred in the biphasic pattern, such as the 1st phase (0~5 min) and the 2nd phase (20~45 min) after formalin injection. However, EA (4~5 mA, 2 ms, 10 Hz) significantly inhibited the behavioral responses. Injection of formalin expressed c-Fos protein on the ipsilateral dorsal horn neurons in L3 - L5 and the expression was sustained more than 4 hrs after formalin injection. However, EA decreased c-Fos protein expression at dorsal horn neurons in the lumbar spinal cord till 4hrs after formalin injection. Conclusions : These results suggest that EA modulates formalin-induced pain and this inhibitory action may be elicited by the descending inhibitory system.

  • PDF

An Economic Evaluation under Thailand Feed in Tariff of Residential Roof Top Photovoltaic Grid Connected System with Energy Storage for Voltage Stability Improving

  • Treephak, Kasem;Saelao, Jerawan;Patcharaprakiti, Nopporn
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.120-128
    • /
    • 2015
  • In this paper, Residential roof top photovoltaic system with 9.9 kW design is proposed. The system composed of 200 Watts solar array 33 panels connecting in series 10 strings and parallels 3 strings which have maximum voltage and current are 350 V and 23.8 A. The 10 kW sinusoidal grid-connected inverter with window voltage about 270-350 is selected to convert and transfer DC Power to AC Power at PCC (Point of Common Coupling) of power system following to utility standard. However the impact of fluctuation and uncertainty of weather condition of PV may decrease the voltage stability and voltage collapse of power system. In order to solve this problem the energy storage such 120 V 1200 Ah battery bank and 30 kVAR capacitor are designed for voltage stability control. The other expensed for installing the system such battery charger, cable, accessories and maintenance cost are concerned. The economic analysis by using investment from money loan with interest about 7% and use own money which loss income of deposit about 3% are calculated as 671,844 and 547,044 for PV system with energy storage and non energy storage respectively. The solar energy from PV is about 101,616 Bath per year which evaluated by using the value of $5kWh/m^2/day$ from average peak sun hour (PSH) of the Thailand and 6.96 Bath/kWh of Feed in Tariff Incentive. The payback periods of four scenarios are proposed follow as i) PV system with energy storage and use loan money is 15 years ii) PV system with no energy storage and use loan money is 10 years iii) PV system with energy storage and use deposit money is 9 years iv) PV system with energy storage and use deposit money is 7 years. In addition, the other scenarios of economic analysis such no FIT support and other type of economic analysis such NPV and IRR are proposed in this paper.

Minimization of a CW CO2 Laser Output Ripple by using High Frequency Resonance Phenomena (고주파 공진현상을 이용한 CW CO2 레이저의 출력리플 최소화)

  • Sikander, Sakura;Kwon, Min-Jae;Kim, Hee-Je;Lee, Dong-Gil;Xu, Guo-Cheng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.798-802
    • /
    • 2013
  • In a conventional DC power supply used for CO2 laser, the circuit elements such as a rectifier bridge, a current-limiting resistor, a high voltage switch, energy storage capacitors ans a high-voltage isolation transformer using high turn ratio are necessary. Consequently, those supplies are expensive and require a large space. Thus, laser resonator and power supply should be optimally designed. In this paper, we propose a new power supply using high frequency resonance phenomena for CW(Continuous wave) CO2 laser (maximum output of 23W with discharge length of 450mm). It consists of a transformer including leakage inductance, magnetizing inductance and half-bridge converter, a three-stage Cockcroft-Walton and PFC(Power factor correction) circuit. The output ripple voltage can be controlled the minimum of 0.24% under the high frequency switching of 231kHz. Furthermore, the output efficiency was improved to 16.4% and the laser output stability of about 5.6% was obtained in this laser system.

Measurement of Partial Conductivity of 8YSZ by Hebb-Wagner Polarization Method

  • Lim, Dae-Kwang;Guk, Jae-Geun;Choi, Hyen-Seok;Song, Sun-Ju
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.299-303
    • /
    • 2015
  • The electrolyte is an important component in determining the performance of Fuel Cells. Especially, investigation of the conduction properties of electrolytes plays a key role in determining the performance of the electrolyte. The electrochemical properties of Yttrium stabilized zirconia (YSZ) were measured to allow the use of this material as an electrolyte for solid oxide fuel cells (SOFC) in the temperature range of $700-1000^{\circ}C$ and in $0.21{\leq}pO_2/atm{\leq}10^{-23}$. A Hebb-Wagner polarization experimental cell was optimally manufactured; here we discuss typical problems associated with making cells. The partial conductivities due to electrons and holes for 8YSZ, which is known as a superior oxygen conductor, were obtained using I-V characteristics based on the Hebb-Wagner polarization method. Activation energies for holes and electrons are $3.99{\pm}0.17eV$ and $1.70{\pm}0.06eV$ respectively. Further, we calculated the oxygen ion conductivity with electron, hole, and total conductivity, which was obtained by DC four probe conductivity measurements. The oxygen ion conductivity was dependent on the temperature; the activation energy was $0.80{\pm}0.10eV$. The electrolyte domain was determined from the top limit, bottom limit, and boundary (p=n) of the oxygen partial pressure. As a result, the electrolyte domain was widely presented in an extensive range of oxygen partial pressures and temperatures.

A Study on the Implementation of Zigbee Sensor Node for Building USN Using only Transmission of Fire Sensing Data (화재감지데이터 전송용 USN망 구축을 위한 지그비 센서노드 구현)

  • Cheon, Dong-Jin;Jung, Do-Young;Kwak, Dong-Kurl
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.75-81
    • /
    • 2009
  • In this paper, USN of wireless communication with easy to install and effectiveness with variety information gathering has been proposed as a alternative of wired-based line for transmission of fire sensing data. But, The sensor node using USN should be considered for wireless transmission range and reliability of information. In this study, the zigbee protocol sensor node was implemented and then tested transmission range of sensor node as 10m interval using voltage information of DC 3V & 5V. Here, maximum transmission distance was confirmed 90m inside-outside. When used mesh routing relay node, distance was not limited. In USN network building, when fire sensing data transmitted, the sensing data same between direct sensing data from sensor and collecting data at USN. Therefore, was confirmed reliability for transmission range and information of proposed zigbee sensor node.

The Study of Method about the Multi-channel Simultaneous Measurement for Measuring the I-V Curve of Photovoltaic Array (태양광 어레이 I-V 곡선 측정을 위한 다채널 동시 측정방법에 관한 연구)

  • Park, Yu-Na;Jang, Gil-Soo;Ko, Suk-Whan;Kang, Gi-Hwan;So, Jung-hun;Jung, Young-Seok;Ju, Young-Chul;Hwang, Hye-Mi;Song, Hyung-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.23-33
    • /
    • 2017
  • A great deal of study for loss reduction of photovoltaic system is conducted currently. It is hard to distinct the fault of photovoltaic system with the naked eye. For that reason, it is essential to repair and maintain the PV system by monitoring the system. The fault of individual modules can cause the huge loss of the entire system because of the mismatch. Therefore, the method of diagnosing the PV array is necessary by measuring the multi-channel arrays simultaneously. In this paper, it is presented the method of measuring I-V curve of multi-channel arrays simultaneously by using the charge and discharge characteristics of capacitor. Generated DC power at PV arrays is charged and discharged at the capacitors in a moment. By measuring the charged voltage and current, it is possible to diagnose of performance of PV arrays.