• Title/Summary/Keyword: DC-link

Search Result 1,020, Processing Time 0.024 seconds

3-Phase Current Estimation of SRM Based on DC-Link Current (직류링크전류를 기반으로 한 SRM 3상전류 추정법)

  • Kim, Ju-Jin;Choi, Jae-Ho;Kim, Tae-Woong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.307-312
    • /
    • 2006
  • This paper proposes the SRM drive system, which accurately estimates the phase currents from the DC-link current to drive SRM instead of detecting the three-phase currents. In addition, the detecting circuit of DC-link current is also proposed to increase the resolution and decrease the off-set influence. Comparing with the general drive system based on the phase current, it is verified through the experiments that the proposed SRM drive system based on the DC-link current has the good performance in steady-state response of the speed control. Using the DC-link current, all of the 3-phase currents can be easily estimated for driving the SRM.

DC link Ripple Voltage Compensation of a Single-phase Grid-Connected PV System (단상 계통연계형 태양광 발전 시스템의 직류링크 맥동전압 보상)

  • Lee, Jae-Geun;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.377-387
    • /
    • 2012
  • A single-phase grid-connected PV system is known as suitable for housing of less than 3 kW. The DC link voltage in a single-phase PV system has necessarily twice component of fundamental wave. It makes high THD in the grid current. According to the problem, power quality is lower. Many engineers have studied about this problem. The most simple method is to use low pass filter on DC link voltage control. However it is affected by DC link voltage control bandwidth. If cutoff frequency is reduced to increase the performance of low pass filter, it also lowers DC link voltage control bandwidth. Second method is using band stop filter, it works good on steady state but not good on transient state. This paper proposes the new method for removing ripple voltage to get an exact current reference. It improves the responses on steady state and transient state. The performance was verified through computer simulation using MATLAB and actual experiments.

A Study on the DC-Link Miniaturization and the Reduction of Output Current Distortion Rate by Reducing the Effect of 120 Hz Ripple Voltage on Photovoltaic Systems (태양광 발전 시스템의 120Hz 리플 전압 영향 감소를 통한 DC-Link 소형화와 출력 전류 왜곡률 감소에 관한 연구)

  • Song, Min-Geun;Lee, Woo-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.342-348
    • /
    • 2021
  • The PV module of solar power systems requires maximum power point tracking (MPPT) technique because the power-voltage and current-voltage characteristics vary depending on the surrounding environment. In addition, the 120 Hz ripple voltage on the DC-Link is caused by the imbalance of the system voltage and current. The effect of this 120 Hz ripple voltage reduces the efficiency of the power generation system by increasing the output current distortion rate. Increasing the capacity of DC-Link can reduce the 120 Hz ripple voltage, but this method is inefficient in price and size. We propose a technique that detects 120 Hz ripple voltage and reduces the effect of ripple voltage without increasing the DC-Link capacity through a controller. The proposed technique was verified through simulations and experiments using a 1 kW single-phase solar power system. In addition, the proposed technique's feasibility was demonstrated by reducing the distortion rate of the output current.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters (2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상)

  • Kim Young-Sin;Lee Dong-Choon;Seok Jul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

The Method of DC-link Balancing on SST using Cascaded H-bridge Rectifier (Cascaded-H-bridge 정류기를 사용하는 SST에서의 DC-link 전압 밸런싱을 위한 방법)

  • Yun, Hyeok-Jin;Kim, Ho-Sung;Kim, Myung-Ho;Baek, Ju-Won;Kim, Hui-Je
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.87-88
    • /
    • 2016
  • 본 논문은, Cascaded-H-bridge 정류기를 사용하는 SST 시스템에서의 DC-link 전압 밸런싱을 위한 실용적이고 구성이 용이한 제어기에 관한 것이다. 제안하는 제어기는 DC-DC stage의 Dual active bridge 컨버터의 개별적인 위상 제어를 통해 DC-link의 전압을 개별 조정한다. 기존의 연구된 전압 밸런싱 기법들에 비해, 제안하는 제어기는 별도의 회로 및 장치가 필요 없고, 확장성이 용이 하며, 구성이 용이하면서 실용성을 가지는 장점들이 있다. 제안하는 제어기는 5kW의 7-level SST 시제품을 제작하여 검증하였다.

  • PDF

A Brushless DC Motor Drive System and Phase Current Estimation Method For Active Knee Prothesis (동력의지를 위한 BLDCM 구동 시스템 및 상전류 추정 기법)

  • Nam, K.J.;Choi, Y.B.;Jung, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.7-12
    • /
    • 2013
  • In this paper, we propose a brushless DC motor drive system for active knee prosthesis and low-cost estimation method for phase current from DC-link current. To control motor torque directly, current sensing is very important and current sensing point should be synchronized with voltage switching command to minimize the effect of switching noise in current measurement, For maintaining small form factor, simplifying control schemes and achieving low-cost system, control schemes using DC-link current are used. Moreover, we incorporated phase current estimation method using analog MUX for minimizing current estimation error between DC-link current and phase current. The validity of the proposed system is verified through experimental works.

  • PDF

A Simple Capacitance Estimation Method for Failure Diagnosis of DC Link Electrolytic Capacitor in Power Converters (전력변환기에 대한 직류링크 커패시터의 고장진단을 위한 간단한 용량 추정 기법)

  • Shon, Jin-Geun;Kim, Dong-Joon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.378-383
    • /
    • 2010
  • Due to the large capacity and low cost, DC link electrolytic capacitors with of energy storage and voltage regulation are used for almost all types of power converter as the DC/AC inverter or DC/DC converter. Electrolytic capacitor, which is the most of the time affected by the aging effect, plays very important role for the power converter system quality and reliability. Therefore, this paper proposes a simple method to estimate the capacitance variation of an electrolytic capacitor in order to analyze the internal characteristic decrease and worn-out state of an electrolytic capacitor. Simulation results by using capacitor storage energy computation show the validity of the proposed capacitance estimation method.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

A Development of Ethernet-Based Remote Diagnosis System for DC Voltage Smoothing Capacitor using DSP (DSP를 적용한 전력용 DC 평활 커패시터의 이더넷 원격 고장진단시스템 개발)

  • Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.94-98
    • /
    • 2011
  • Electrolytic power capacitors today form essential components for virtually any power electronic system such as DC/DC converter or UPS. Frequently, electrolytic capacitors for DC link voltage smoothing are the key components which determine the life cycle of the whole unit and often are responsible for converter breakdown failures. In this paper, ethernet-based remote diagnosis system for DC voltage smoothing capacitor using DSP control board is developed. To estimate the status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The ESR detection scheme is based on the determination of the capacitor ripple power losses calculated from DC link voltage/current measurement. Experimental results show the veridity and reliability of the proposed ethernet-based remote on-line capacitor diagnosis system.

Capacitance Estimation of DC-Link Capacitors of Three-phase AC/DC/AC PWM Converters (3상 AC/DC/AC PWM 컨버터의 DC-Link 커패시터 용량 추정)

  • Lee Kang-Ju;Lee Dong-Choon;Seok Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.399-402
    • /
    • 2002
  • In this paper, the novel method is proposed to measure the capacitance of the dc link capacitor Advantage of the method is not to separate capacitor from 3-phase AC/DC/AC converters. In the proposed method, a specific low frequency current is injected to oscillate the voltage of dc capacitor at no load condition. The capacitance of dc capacitor is calculated with the effective values of this ripple voltage and current. The validity of the proposed method is confirmed by PSIM simulation.

  • PDF