• Title/Summary/Keyword: DC-link

Search Result 1,020, Processing Time 0.044 seconds

Versatile Shunt Hybrid Power Filter to Simultaneously Compensate Harmonic Currents and Reactive Power

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1311-1318
    • /
    • 2015
  • This paper introduces a novel topology and an effective control strategy for a shunt hybrid power filter (SHPF) to simultaneously compensate harmonic currents and reactive power. The proposed SHPF topology is composed of an LC passive filter tuned to the 7th harmonic frequency and a small-rated active filter connected in parallel with the inductor Lpf of the LC passive filter. Together with the SHPF topology, we also propose a control strategy, which consists of a proportional-integral (PI) controller for DC-link voltage regulation and a PI plus repetitive current controller, in order to compensate both the harmonic current and the reactive power without the need for additional hardware. Thanks to the effectiveness of the proposed control scheme, the supply current is sufficiently compensated to be sinusoidal and in-phase with the supply voltage, regardless of the distorted and phase lagging of the load current. The effectiveness of the proposed SHPF topology and control strategy is verified by simulated and experimental results.

유도전동기 운전 중 Sag 영향에 의한 고조파 차수 변화 (Induction Motor of Effect for Variation Sag, Swell of Harmonic Order)

  • 박인덕;이승환;김시경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.954-955
    • /
    • 2008
  • In this paper, the voltage harmonics are investigated in terms of the voltage sag versus the time constants of electric machinery under the source voltage variation condition. The electric machinery and compensation equipment are established on the proposed design scheme based on voltage quality effect assessment technology. It have been analyzed how the variation of harmonic order, the output current, the DC-Link voltage and the induction motor speed is carried out under the voltage sag and switching frequency variation.

  • PDF

NN-SV PWM을 이용한 IPMSM 드라이브의 고성능 속도제어 (High Performance Speed Control of IPMSM Drive Using Neural Network-SV PWM)

  • 김도연;고재섭;최정식;정철호;정병진;박기태;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.958-959
    • /
    • 2008
  • This paper is proposed a high performance speed control of the Interior Permanent Magnet Synchronous Motor through the Neural Network SV-PWM. SV-PWM is controlled using Neural Network control. SV-PWM can be maximum used maximum dc link voltage and is excellent control method due to characteristic to reducing harmonic more than others. Neural Network control has a advantage which can be robustly controlled. Simulation results are presented to show the validity of the proposed algorithm.

  • PDF

연료 전지 BOP 내장 터보 블로어용 초고속 영구자석 동기전동기 드라이버 구현 (Implementation of Super High Speed PMSM Driver for Turbo blower in Fuel Cells BOP)

  • 최순호;부우충기엔;차한주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.978-979
    • /
    • 2008
  • 본 논문에서는 TMS320F2812를 이용하여 연료 전지 BOP(Balance of Plant) 내장 터보 블로어로 쓰이는 영구자석 동기전동기의 센서리스 공간 벡터 제어를 구현하였다. 고속으로 회전하는 회전자의 위치 및 속도는 측정하기가 어려우므로, 전류를 이용하여 위상 및 속도를 추정하였으며, 이 알고리즘을 Digital Signal Processor(DSP) 상에서 구현하였다. 전류 측정시 노이즈에 의한 영향을 최소화하기 위해 외부에 12bit급 AD컨버터인 AD7891을 장착하였다. 데드타임 보상 및 dc-link 전압 리플 보상을 적용하였고, 정격 속도 100,000rpm에서 영구자석 동기전동기를 구동하였다.

  • PDF

영구자석 동기발전기 시스템을 위한 회전자 관성에너지를 이용한 Sliding Mode제어 기반 LVRT 제어 (Use of Stored Energy in Rotor Inertia for LVRT of PMSG Wind turbine based on Sliding Mode Control)

  • 정대헌;계용호;김청훈;정정주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1058-1059
    • /
    • 2015
  • This paper describes a low-voltage ride-through method for the permanent magnet synchronous generator (PMSG) wind turbine system at a grid fault. The generator side converter regulates the DC link voltage instead of the grid side converter by storing the surplus active power in the rotor inertia during grid fault by the sliding mode controller. The grid side converter controls the grid active power keeping a maximum power point tracking. Simulation results for small scale PMSG wind turbine verify the efficiency of the control method.

  • PDF

인공지능 SV-PWM 제어를 이용한 SynRM의 고성능 제어 (High Performance Control of SynRM using Artificial Intelligent SV-PWM Control)

  • 김도연;고재섭;최정식;정철호;정병진;전영선;정동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.391-394
    • /
    • 2008
  • This paper is proposed a high performance speed control of the synchronous reluctance motor through the artificial intelligent SV-PWM. SV-PWM is controlled using fuzzy control that is artificial intelligent control. SV-PWM can be maximum used maximum dc link voltage and is excellent control method due to characteristic to reducing harmonic more than others. Fuzzy control has a advantage which can be robustly controlled. Simulation results are presented to show the validity of the proposed algorithm

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

변압기 없는 계통연계형 PV PCS고찰 (Transformer-less Type Grid-Connected PV Power Conditioning System)

  • 정영석;유권종;정명웅;최재호;최주엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF

고주파 전자식 안정기의 새로운 제어방법 (A New Control Method for The High Frequency Electronic Ballast)

  • 오덕진;김희준;조규민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.746-749
    • /
    • 2002
  • This paper presents a new control method for the high frequency electronic ballast which is operated with raw rectified dc link using diode bridge. For the commercial electronic ballast, proper ac input power factor and crest factor of the lamp current are required. The most ballast, therefore, has a active or passive power factor collection (PFC) circuit. With the proposed method, it can be achieved simultaneously that grater than 0.9 of input power factor and less than 1.85 of lamp current crest factor without any PFC circuit. In this paper, the proposed ballast control scheme and the experimental results for the application to the fluorescent lamp are described.

  • PDF

회생에너지의 부스트인버터 구동방식을 적용한 서보시스템의 응답특성 향상 (Improving Quick Response of Servo System Using Boost-Diverter with Regenerating Energy)

  • 김태웅;최재호;민완기;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.339-341
    • /
    • 2006
  • The regenerating energy of the servo system is mostly consumed as heats through the regenerating resistors. For the response of the servo system to be more improved, the paper proposes the boost inverter using the regenerating energy, The proposed boost inverter has the additional capacitor installed on the DC-link circuit for charging the regenerating energy from the load. To get the better response of the servo system, the charged regenerating energy can be shortly re-applied to the output side as the finite impulse voltage, which can be controlled from information of reference voltages and feedbacked currents. It is verified by PSIM simulator that the response characteristics of the servo system using the proposed boost inventer is improved, comparing to that using the general inverter.

  • PDF