• 제목/요약/키워드: DC transmission

검색결과 477건 처리시간 0.028초

극 수에 따른 저압직류 배전계통의 순시전압강하 분석 (Analysis on Voltage Sag in Low Voltage DC Distribution System according to the Number of Poles)

  • 노철호;김두웅;권기현;오윤식;한준;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.66-73
    • /
    • 2015
  • AC-based power systems, having the advantages that voltage transformation and long distance transmission are easy, have been constructed since the last 19th century. However, DC-based power system is paid attention these days because of the development of power electronic devices as well as the increase of digital loads and distributed generation. For instance, the transmission systems using High Voltage DC (HVDC) are commercially operated in the world and the researches on distribution system using Low Voltage DC (LVDC) are gradually increased. This paper analyzes voltage sag, resulted from faults, in LVDC distribution system according to the number of poles. Modeling and simulation with various conditions are conducted by using ElectroMagnetic Transients Program (EMTP). Moreover, some countermeasures to reduce voltage sag in LVDC distribution system are suggested briefly.

An Improved Flux Estimator for Gap Flux Orientation Control of DC-Excited Synchronous Machines

  • Xu, Yajun;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.419-430
    • /
    • 2015
  • Flux estimation is a significant foundation of high-performance control for DC-excited synchronous motor. For almost all flux estimators, such as the flux estimator based on phase locked loop (PLL), DC drift causes fluctuations in flux magnitude. Furthermore, significant dynamic error may be introduced at transient conditions. To overcome these problems, this paper proposes an improved flux estimator for the PLL-based algorithm. Filters based on the generalized integrator are used to avoid flux fluctuation problems caused by the DC drift at the back electromotive force. Programmable low-pass filters are employed to improve the dynamic performance of the flux estimator, and the cutoff frequency of the filter is determined by the dynamic factor. The algorithm is verified by a 960V/1.6MW industrial prototype. Simulation and experimental results show that the proposed estimator can estimate the flux more accurately than the PLL-based algorithm in a cycloconverter-fed DC-excited synchronous machine vector control system.

레이저 다이오드를 이용한 수중 광 정보 및 전력 동시전송 (Underwater Simultaneous Light Information and Power Transmission using a Laser Diode)

  • 김성만;신재우
    • 한국전자통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.853-858
    • /
    • 2022
  • 본 논문에서는 레이저 다이오드를 활용하여 수중 광 전력과 수중 광 무선통신의 동시전송을 연구하고 이에 대한 실험 결과를 보인다. 본 실험에서는 송신부에 전/광 변환을 위한 레이저 다이오드를 사용하고 수신부에는 광/전 변환을 위한 태양전지를 사용하였다. 수중 전송 실험을 위해서는 플라스틱 관에 물을 채워 구현하였으며, 수중 광 무선통신 및 수중 광 무선충전을 위해 레이저 송신단과 수신단 시스템을 최적화하였다. 본 실험에서는 100 mW 급 레이저를 사용하였으며, 레이저의 최대 전/광 변환효율을 18.5 % 였다. 수중 광 무선충전 및 수중 광 무선통신의 동시전송 실험결과, 수중에서 최대 5 m 전송시에 0.33 %의 DC-to-DC 전송효율을 보였으며, 수중 무선 광통신은 수중에서 1 m 전송시에 최대 50 kbps의 전송속도를 보였다.

5.8-GHz무선전력수신기를 이용한 스마트폰 RF 무선충전 (Smart Phone RF Wireless Charging with 5.8-GHz Microwave Wireless Power Receiver)

  • 손명식
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.25-28
    • /
    • 2021
  • In this paper, we studied smart phone RF wireless charging with 5.8-GHz microwave wireless power receiver. The dc output of the receiver connected to super capacitor and DC-DC converter for charging a smart phone. This configuration stably supplies 5V and current for charging it. Studies show that the more receivers are used at close range, the higher the received voltage values and the larger the capacity of the super capacitor, the longer the charging time. The present 5.8-GHz 1W wireless power transmission system is not enough for charging a smartphone mainly due to the lack of current of the receiver.

Numerical Simulation of the Characteristics of Electrons in Bar-plate DC Negative Corona Discharge Based on a Plasma Chemical Model

  • Liu, Kang-Lin;Liao, Rui-Jin;Zhao, Xue-Tong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1804-1814
    • /
    • 2015
  • In order to explore the characteristics of electrons in DC negative corona discharge, an improved plasma chemical model is presented for the simulation of bar-plate DC corona discharge in dry air. The model is based on plasma hydrodynamics and chemical models in which 12 species are considered. In addition, the photoionization and secondary electron emission effect are also incorporated within the model as well. Based on this model, electron mean energy distribution (EMED), electron density distribution (EDD), generation and dissipation rates of electron at 6 typical time points during a pulse are discussed emphatically. The obtained results show that, the maximum of electron mean energy (EME) appears in field ionization layer which moves towards the anode as time progresses, and its value decreases gradually. Within a pulse process, the electron density (ED) in cathode sheath almost keeps 0, and the maximum of ED appears in the outer layer of the cathode sheath. Among all reactions, R1 and R2 are regarded as the main process of electron proliferation, and R22 plays a dominant role in the dissipation process of electron. The obtained results will provide valuable insights to the physical mechanism of negative corona discharge in air.

변류기를 이용한 자가발전 장치의 설계와 특성 (Design and Properties of a Self Generation Equipment using Current Transformer)

  • 변우봉;김현식;김종령;이해연;이준희;지민권;이진;오영우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.427-428
    • /
    • 2008
  • We have studied design and application about an self generation equipment for underground power transmission cable. The split CT(Current Transformer), which has the applicable underground power transmission cable, was manufactured through electromagnetic simulation of magnetic core. And manufactured the AC-DC converter that supplied stable DC power for PLC modem when current of power line has more than 150A. An self generation equipment using the CT and AC-DC converter get into operation the PLC modem consistently. As a result, the underground power transmission cable was showed the application possibility through the stable communication and network characteristics.

  • PDF

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

A New Reclosing and Re-breaking DC Thyristor Circuit Breaker for DC Distribution Applications

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.272-281
    • /
    • 2017
  • The DC circuit breaker is essential for supplying stable DC power with the advent of DC transmission/distribution and sensitive loads. Compared with mechanical circuit breakers, which must interrupt a very large fault current due to their slow breaking capability, a solid-state circuit breaker (SSCB) can quickly break a fault current almost within 1 [ms]. Thus, it can reduce the damage of an accident a lot more than mechanical circuit breakers. However, previous DC SSCBs cannot perform the operating duty, and are not economical because many SCR are required. Therefore, this paper proposes a new DC SSCB suitable for DC grids. It has a low semiconductor conduction loss, quick reclosing and rebreaking capabilities. As a result, it can perform the operating duties of reclosing and rebreaking. The proposed DC SSCB is designed and implemented so that it is suitable for home dc distribution at a rated power of 5 [kW] and a voltage of 380 [V]. The operating characteristics are confirmed by simulation and experimental results. In addition, this paper suggests design guidelines so that it can be applied to other DC grids. It is anticipated that the proposed DC SSCB may be utilized to design and realize many DC grid systems.

전력계통 연계를 대비한 마이크로파 무선전력 송수신기 에레이 구성 고찰 (Array Topology of Microwave Wireless Power Transmission on Electronic Power System)

  • 이동호
    • 한국위성정보통신학회논문지
    • /
    • 제10권1호
    • /
    • pp.88-91
    • /
    • 2015
  • 무선전력전송은 별도의 전송선로 없이 에너지를 전달하는 기법으로, 기존의 무선통신에서의 신호가 아닌 에너지 자체의 전달을 목적으로 한다. 원거리 마이크로파 전력송수신기는 RF 발진회로, 고이득 안테나, 정류회로 등으로 구성되는데, 상용화를 위해서는 저렴한 고출력 발진회로 및 설치가 용이한 안테나 설계의 어려움이 해결되어야할 과제이다. 이것 때문에 발진회로와 개별 안테나가 각각 연결된 에너이로 구성된 시스템 채택이 예상된다. 본 고찰는 무선전력 송수신기의 전력계통의 영향 분석 일환으로 수행하였다.

저수지 내 수상태양광의 전압 강하에 의한 직류 송전 손실 (Transmission Loss from Voltage Drop in a DC Cable for a Floating Photovoltaic System in a Reservoir)

  • 방병관;우성철;이원빈;최진호;신승욱;이철성;박미란;원창섭;안형근
    • 신재생에너지
    • /
    • 제16권1호
    • /
    • pp.47-57
    • /
    • 2020
  • In Floating PV (Photovoltaic) systems, PV modules are installed on water by utilizing the surface of idle water such as a reservoir and multipurpose dam. A floating PV system, therefore, has the advantage of efficiency in national land use and improved energy yield owing to cooling effect compared to on-land PV systems. Owing to the limitation of installation environment for a floating PV system, the system, however, has the disadvantage of an increase in transmission distance of DC (Direct current) cables. A longer transmission distance of a DC cable results in greater power loss due to a voltage drop. This leads to a decline in economic feasibility for the floating PV system. In this paper, the economic analysis for 10 floating PV systems installed in a reservoir has been conducted in terms of a change in annual power sales according to the variation of transmission losses depending on the factors affecting the voltage drop, such as transmission distance, cross-section area of underwater cable, the presence of joint box, and PV capacity.