• Title/Summary/Keyword: DC removal

Search Result 93, Processing Time 0.024 seconds

Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater (중금속폐수에서 구리의 전기화학적 침전처리)

  • 김재우;이재동;이우식;지은상
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

Aquatic Plants for Wastewater Treatment (수생식물을 이용한 수질정화에 관한 연구)

  • 나규환;권성환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.49-55
    • /
    • 1996
  • Water parsley(Oenanthe javanica(Blume) DC) was raised with varying population density(S) in the laboratory aquarium unit to determine the growth equation. The population density was measure after 7 days. The resultant growth curve was well fit to the equation 1/S = A+B (1/S0) with a high correlation coefficient ($R^2$ = 0.999). The maximum specific absorption rate was $9.011 \times 10^{-5}$ kg $NO_x-N/kg$ water parsley$\cdot$day and $1.31 \times 10^{-5}$ kg $PO_4-P/kg$ water parsley$\cdot$day when the average population density was $2.62 kg/m^2$. The relationship between population density and nutrient absorption rate, the absorption rate of $NO_x-N$ was 5.04~5.24 mg/l$\cdot$day when the population density was $7.51~10.0 $mg/m^2\cdot day$ and the absorption rate of $PO_4-P$ was 0.56~0.78 mg/l$\cdot$day when the population density was 5.02~10.0 $kg/m^2\cdot day$. Taking into account the nutrient absorption rate and growth rate, the population density between $7.0 kg/m^2\cdot day$ and $8.0 kg/m^2 \cdot day$ was selected. The removal rate of nutrient was investigated after 7 days culture. Removal rate of $NO_x-N$ was 95.6~99.95% with initial concentration of 35 mg $NO_x-N/l$, and the removal rate of $PO_4-P$ was also high, indicating 80.24~98.9% with initial concentration of 5.95 mg $PO_x-P/l$.

  • PDF

Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향)

  • Park, Jae-Yun;Go, Hui-Seok;Son, Seong-Do;Lee, Dong-Hun;Kim, Jong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

The removal characteristics of No, SOx for plasma reactor separated flue gas duct from discharge domain (연소가스관로와 방전영역 분리형 플라즈마 반응기에서 Nox, SOx 제거특성)

  • Park, J.Y.;Koh, Y.S.;Lee, J.D.;Song, W.S.;Park, S.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2007-2009
    • /
    • 1999
  • In this paper, discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution. Ammonia gas(14.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio[MR] was determined based on $NH_3$ to [NO+$SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration but SOx removal rate was not significantly effect by initial concentration, and NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Double versus single cartridge of 4% articaine infiltration into the retro-molar area for lower third molar surgery

  • Sawang, Kamonpun;Chaiyasamut, Teeranut;Kiattavornchareon, Sirichai;Pairuchvej, Verasak;Bhattarai, Bishwa Prakash;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.2
    • /
    • pp.121-127
    • /
    • 2017
  • Background: There are no studies regarding 4% articaine infiltration injection into the retro-molar area for an impacted lower third molar (LITM) surgery. This study aimed to evaluate the efficacy of infiltration using 1.7 ml (single cartridge: SC) of 4% articaine versus 3.4 ml (double cartridges: DC) of 4% articaine with 1:100,000 epinephrine in LITM surgery. Method: This study involved 30 healthy patients with symmetrical LITM. The patients were assigned to receive either a DC or SC of 4% articaine with 1:100,000 epinephrine as a local anesthetic for each operation. Onset, duration, profoundness, need for additional anesthetic administration, total volume of anesthetic used, vitality of the tooth, and pain score during operation were recorded. Results: The DC of 4 % articaine had a significantly higher success rate (83.3%) than did the SC (53.3%; P<0.05). The duration of soft tissue anesthesia was longer in the DC group. The intra-operative pain was higher in the SC group with a significant (P < 0.05) requirement for a supplementary local anesthetic. Conclusion: We concluded that using DC for the infiltration injection had a higher success rate, longer duration of anesthesia, less intra-operative pain, and a lower amount of additional anesthesia than SC in the surgical removal of LITM. We recommend that a DC of 4% articaine and a 1:100,000 epinephrine infiltration in the retro-molar region can be an alternative anesthetic for LITM surgery.

Phytoremediation Technology with Using Water Celery (Oenanthe stolonifer DC.) to Clean up Heavy Metals in the Contaminated Wastewater (미나리 재배에 의한 중금속 오염수의 식물정화)

  • Park, Jong-Sun;Han, Sung-Su;Yoon, Duck-Joong;Shin, Joung-Du
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.122-129
    • /
    • 2002
  • The removal rate of heavy metals from the wastewater, the accumulation and translocation of heavy metals in plants after transplanting, and the responses of water celery growth with different wastewater treatments were investigated to determine the potential ability of green-remediation with hydroponic culture of water celery. The removal rate and translocation of Cd, Cu, Ni and Pb from different wastewater to plants were compared with cultivation periods after transplanting. The removal rate of heavy metals from wastewater was different with each treatment but increased with growing periods of water celery plants. The removal rate of Cd, Cu, Ni and Pb in Artificial solution, Artificial solution+EDTA, Munmark industrical wastewater, Jungsun minewater is ranged from 22 to 73%, from 28 to 100%, from 13 to 92% and from 41 to 100% at 6 days after transplanting, respectively. The translocations of Cd, Cu, Ni and Pb from roots to shoots in Artificial solution, Artificial solution+EDTA, Munmark industrical wastewater, Jungsun minewater are ranged from 14 to 28%. 8 to 30%. from 28 to 45% and from 2 to 15% at 12 days after transplanting, respectively. In plant growth responses, it appears to be inhibited the plant growth over all treatments excepts for Munmark industrial wastewater in these glowing periods. Therefore the water celery might play a useful role in phytoremediation to clean up wastewater contaminated with Cd, Cu, Ni or Pb.

NOx Removal Using DC Corona Discharge Under Magetic Field (자계하의 DC 코로나 방전에 의한 NOx 제거)

  • Kim, G.H.;Kim, Jong-Dal;Lee, D.C.;Koh, H.S.;Park, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF

Construction Two Degree of freedom PID controller with Neural network for drives of DC servo motor (DC 서보모터 구동을 위한 신경망 2자유도 PID제어기 구성)

  • 박광현;허진영;하홍곤
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.395-398
    • /
    • 2001
  • In this paper, we consider to apply of 2-DOF (Degree of Freedom) PID controller at D.C servo motor system. Many control system use I-PD, PID control system but the position control system have difficulty in controling variable load and changing parameter. We propose neural network 2-DOF PID control system haying feature for removal disturbances and tracking function in the target value point. Experiment result for 2-DOF PID controller with neural network are illustrated.

  • PDF

THE EFFECTS OF ANNEALING ON THE DC MAGNETIC PROPERTIES OF AN IRON-BASED AMORPHOUS ALLOY

  • Choi, Y.S.;Kim, D.H.;Lim, S.H.;Noh, T.H.;Kang, I.K.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.478-482
    • /
    • 1995
  • The iron-based Metglas 2605S3A amorphous alloy ribbons are annealed at $435^{\circ}C$ for various periods from 5 to 210 min, and the effect of annealing is investigated on the dc magnetic properties of the ribbon. Typical square-type hysteresis loops are observed for the ribbons annealed fo 5 min, indicative of the nearly complete removal of residual stresses which are produced during melt-quenching. As the annealing time increases, the coercivity increases and the shape of hysteresis loops transforms to round type and finally to sheared one at the longest annealing time of 210 min. These results may be explained by the formation of clusters with chemical shortorder and very fine crystallites (at the annealing time of 210 min), and the diffusion-induced stresses during the formation of the clusters. For the samples annealed for 5 min, very good dc properties of the squareness ratio, coercivity and maximum permeability are observed, but, rather unexpectedly, the initial permeability is found to be very low. These results are considered to be due to a simple domain structure consisting of very small number of $^{\circ}$ domains.

  • PDF

Circuit Design for Noise Removal of Sine Wave Hall Sensor Signal (정현파 Hall Sensor 신호의 잡음제거를 위한 회로설계)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.4
    • /
    • pp.135-141
    • /
    • 2021
  • Interest is growing in the design and development of square wave driven BLDC permanent magnet motors suitable for industrial automation, and the development of position detection circuits and drivers. However, this motor is somewhat limited in its application despite the price and functional advantages due to the decrease in efficiency due to switching loss and vibration and noise. In the process of designing and assembling a BLDC motor, the magnetic pole angle is not uniform or the magnetic flux distribution is distorted due to problems in magnetic circuit design or product non-uniformity in the assembly process. Therefore, these things cause position detection deviation and deteriorate the motor characteristics. In addition, the sine wave driven BLDC system can operate stably only when the signal generated from the position sensor is accurately fed back to the driver. However, since the generated signal cannot perform stable position detection due to the occurrence of DC offset component due to magnetic flux density deviation or magnetization technology, which is an external influence, this study intends to study the proposed circuit that can remove the DC offset component.