• 제목/요약/키워드: DC removal

검색결과 93건 처리시간 0.028초

중금속폐수에서 구리의 전기화학적 침전처리 (Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater)

  • 김재우;이재동;이우식;지은상
    • 한국환경보건학회지
    • /
    • 제23권3호
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

수생식물을 이용한 수질정화에 관한 연구 (Aquatic Plants for Wastewater Treatment)

  • 나규환;권성환;이장훈
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.49-55
    • /
    • 1996
  • Water parsley(Oenanthe javanica(Blume) DC) was raised with varying population density(S) in the laboratory aquarium unit to determine the growth equation. The population density was measure after 7 days. The resultant growth curve was well fit to the equation 1/S = A+B (1/S0) with a high correlation coefficient ($R^2$ = 0.999). The maximum specific absorption rate was $9.011 \times 10^{-5}$ kg $NO_x-N/kg$ water parsley$\cdot$day and $1.31 \times 10^{-5}$ kg $PO_4-P/kg$ water parsley$\cdot$day when the average population density was $2.62 kg/m^2$. The relationship between population density and nutrient absorption rate, the absorption rate of $NO_x-N$ was 5.04~5.24 mg/l$\cdot$day when the population density was $7.51~10.0 $mg/m^2\cdot day$ and the absorption rate of $PO_4-P$ was 0.56~0.78 mg/l$\cdot$day when the population density was 5.02~10.0 $kg/m^2\cdot day$. Taking into account the nutrient absorption rate and growth rate, the population density between $7.0 kg/m^2\cdot day$ and $8.0 kg/m^2 \cdot day$ was selected. The removal rate of nutrient was investigated after 7 days culture. Removal rate of $NO_x-N$ was 95.6~99.95% with initial concentration of 35 mg $NO_x-N/l$, and the removal rate of $PO_4-P$ was also high, indicating 80.24~98.9% with initial concentration of 5.95 mg $PO_x-P/l$.

  • PDF

선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향 (Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor)

  • 박재윤;고희석;손성도;이동훈;김종달
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권2호
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

연소가스관로와 방전영역 분리형 플라즈마 반응기에서 Nox, SOx 제거특성 (The removal characteristics of No, SOx for plasma reactor separated flue gas duct from discharge domain)

  • 박재윤;고용술;이재동;송원섭;박상현;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2007-2009
    • /
    • 1999
  • In this paper, discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution. Ammonia gas(14.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio[MR] was determined based on $NH_3$ to [NO+$SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration but SOx removal rate was not significantly effect by initial concentration, and NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Double versus single cartridge of 4% articaine infiltration into the retro-molar area for lower third molar surgery

  • Sawang, Kamonpun;Chaiyasamut, Teeranut;Kiattavornchareon, Sirichai;Pairuchvej, Verasak;Bhattarai, Bishwa Prakash;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권2호
    • /
    • pp.121-127
    • /
    • 2017
  • Background: There are no studies regarding 4% articaine infiltration injection into the retro-molar area for an impacted lower third molar (LITM) surgery. This study aimed to evaluate the efficacy of infiltration using 1.7 ml (single cartridge: SC) of 4% articaine versus 3.4 ml (double cartridges: DC) of 4% articaine with 1:100,000 epinephrine in LITM surgery. Method: This study involved 30 healthy patients with symmetrical LITM. The patients were assigned to receive either a DC or SC of 4% articaine with 1:100,000 epinephrine as a local anesthetic for each operation. Onset, duration, profoundness, need for additional anesthetic administration, total volume of anesthetic used, vitality of the tooth, and pain score during operation were recorded. Results: The DC of 4 % articaine had a significantly higher success rate (83.3%) than did the SC (53.3%; P<0.05). The duration of soft tissue anesthesia was longer in the DC group. The intra-operative pain was higher in the SC group with a significant (P < 0.05) requirement for a supplementary local anesthetic. Conclusion: We concluded that using DC for the infiltration injection had a higher success rate, longer duration of anesthesia, less intra-operative pain, and a lower amount of additional anesthesia than SC in the surgical removal of LITM. We recommend that a DC of 4% articaine and a 1:100,000 epinephrine infiltration in the retro-molar region can be an alternative anesthetic for LITM surgery.

미나리 재배에 의한 중금속 오염수의 식물정화 (Phytoremediation Technology with Using Water Celery (Oenanthe stolonifer DC.) to Clean up Heavy Metals in the Contaminated Wastewater)

  • 박종선;한성수;윤덕중;신중두
    • 한국환경농학회지
    • /
    • 제21권2호
    • /
    • pp.122-129
    • /
    • 2002
  • 중금속 오염원을 제거하는 기술을 개발하고자 미나리를 도입하여 중금속 종류에 따른 적정 농도별로 중금속 흡수, 정화효율성 및 식물체내에서 중금속 축적과 이행과정을 조사하였다. 미나리를 이용한 중금속 정화효율성은 Cd의 경우 미나리 정식 6일 후 Artificial solution 처리구와 문막 공업폐수 처리구는 각각 53%, 73%의 정화효율성을 보였으며, Cu의 경우에는 각각 28%, 100%의 정화효율성을 보였다. 환경부에서 규정한 Cd의 청정지역 배출허용기준인 0.02 mg/L은 모든 처리구에서 10일 이후에 나타났으며, Cu의 기준농도인 0.5 mg/L은 Artificial solution 처리구의 경우 10일 이후, 문막 공업폐수 처리구는 3시간 이후에 나타났다. 또한 시간이 경과함에 따라 미나리내 중금속의 축적농도는 높아지는 경향을 보였으며, 처리구의 오염수 중금속 농도보다도 5$\sim$10배 이상 축적되었다. 미나리 식물체에 흡수된 중금속의 뿌리에서 지상부로의 이행율은 Artificial solution 처리구에서 Cd은 25%, 문막 공업폐수 처리구에서 Cu는 25% 이행하였다. 중금속에 대한 미나리의 생육반응은 문막 공업폐수 처리를 제외한 모든 처리구에서 미나리 생장이 억제되는 결과를 보였다. 따라서 본 연구결과 미나리는 중금속 오염수의 중금속 정화를 위한 식물정화기술에 유용하게 활용할 수 있을 것으로 판단된다.

자계하의 DC 코로나 방전에 의한 NOx 제거 (NOx Removal Using DC Corona Discharge Under Magetic Field)

  • 김건호;김종달;이덕출;고희석;박재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF

DC 서보모터 구동을 위한 신경망 2자유도 PID제어기 구성 (Construction Two Degree of freedom PID controller with Neural network for drives of DC servo motor)

  • 박광현;허진영;하홍곤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.395-398
    • /
    • 2001
  • 본 논문에서는 직류 서보 전동기를 구동원으로 하는 위치 제어계에서 부하변동에 따른 파라메타 변화, 외란 둥에 강인한 2자유도 PID 제어기의 설계법을 제시하여 신경망으로 2자유도 PID 제어기를 구성하였다. 이 제어기의 계수들이 기동시나 계 응답의 변동시 신경망 역전파 알고리즘(Back-Propagation Algorithm)에 의해서도 수성 되도록 하였다. 그리고 이것을 실제의 위치 제어계에 적용하여 실험을 통해 그 성능을 검증하였다.

  • PDF

THE EFFECTS OF ANNEALING ON THE DC MAGNETIC PROPERTIES OF AN IRON-BASED AMORPHOUS ALLOY

  • Choi, Y.S.;Kim, D.H.;Lim, S.H.;Noh, T.H.;Kang, I.K.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.478-482
    • /
    • 1995
  • The iron-based Metglas 2605S3A amorphous alloy ribbons are annealed at $435^{\circ}C$ for various periods from 5 to 210 min, and the effect of annealing is investigated on the dc magnetic properties of the ribbon. Typical square-type hysteresis loops are observed for the ribbons annealed fo 5 min, indicative of the nearly complete removal of residual stresses which are produced during melt-quenching. As the annealing time increases, the coercivity increases and the shape of hysteresis loops transforms to round type and finally to sheared one at the longest annealing time of 210 min. These results may be explained by the formation of clusters with chemical shortorder and very fine crystallites (at the annealing time of 210 min), and the diffusion-induced stresses during the formation of the clusters. For the samples annealed for 5 min, very good dc properties of the squareness ratio, coercivity and maximum permeability are observed, but, rather unexpectedly, the initial permeability is found to be very low. These results are considered to be due to a simple domain structure consisting of very small number of $^{\circ}$ domains.

  • PDF

정현파 Hall Sensor 신호의 잡음제거를 위한 회로설계 (Circuit Design for Noise Removal of Sine Wave Hall Sensor Signal)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권4호
    • /
    • pp.135-141
    • /
    • 2021
  • 산업자동화에 적합한 구형파 구동 BLDC 영구자석 전동기 설계 및 개발, 위치검출방식 회로와 드라이버 개발에 관심이 증가하고 있다. 그러나 이 전동기는 스위칭 손실에 의한 효율 저하 및 진동, 소음 등으로 인하여 가격적·기능적인 장점에도 불구하고 그 응용에 있어서는 다소 제한적인 실정이다. BLDC 모터를 설계하고 조립하는 과정에 있어 자기회로 설계의 문제 또는 조립과정상의 제품 불 균일 등으로 인하여 자극 각이 균일하지 않거나 자속분포가 왜현되는 문제가 발생하는데, 이러한 것들이 위치검출 어긋남의 원인이 되어 모터 특성을 악화시킨다. 또한 위치센서로부터 발생된 신호가 정확히 드라이버로 피드백 되어야만 정현파 구동 BLDC 시스템이 안정적으로 동작할 수 있다. 그러나 발생된 신호가 외부의 영향인 자속밀도 편차나 착자 기술에 의해 DC offset 성분이 발생하여 안정적인 위치검출을 할 수 없기에 본 연구에서는 DC offset 성분을 제거할 수 있는 제안된 회로를 연구하고자 한다.