• Title/Summary/Keyword: DC removal

Search Result 93, Processing Time 0.023 seconds

Bidirectional pulse generator for removal of flue gas (배기가스 처리용 양방향 펄스 전원)

  • 박정호;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.233-236
    • /
    • 1997
  • An investigation has been made of the various plasma chemistry reactions that occur in the corona discharge of an electrostatic precipitator operating in a typical flue gas. As the results of investigation, sulphur dioxide is removed principally by reactions with OH radicals to produce sulphuric acid, while nitrogen oxides are removed principally by reduction via the N radical to molecular nitrogen. If electrostatic precipitator\ulcorner used for flue gases are operated with positive voltages instead of negative dc voltages, there are significant reductions in the emission of the undesirable gases SO$_2$, NO, and NO$_2$. Thus, in this paper we design the bidirectional pulse generator for removal of flue gas, where the pulse width is more than 50[nsec] and the maximum output voltage is more than 100[kVl.

  • PDF

A Study on the Removal of an Heavy Metal Ions by an Functional Nano Fibers (기능성 나노섬유에 의한 중금속 이온의 제거에 관한 연구)

  • An Hyung-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.57-64
    • /
    • 2004
  • This is the study for the removal of a toxic heavy metal ions and the recycling of expanded polystyrene wastes. Thus expanded polystyrene wastes collected from the packing materials of TV or chemicals and dissolved by $80wt.\%$ solvent(N, N-Dimethylacrylamide), electrospun in DC 20kV by power supply. Generally, the electrospinning is a process of manufacture to the fibers of nanosize from polymer solution. Manufactured nanofiber mats by electrospinning were sulfonated by cone.-sulphuric acid with $Ag_2S_O_4$ catalysts for the exchange capacity of heavy metal ions and the properties of structure with sulfonated time investigated by FESEM(Feild Emission Scaning Electron Microscope). The ion exchange capacity of light metal$(Na^+)$, Cd(II) and Ni(II), and by a nanofiber mats were 1.94[mmo1/g-dry-mat), 1.72(mmol/g-dry-mat), 1.24(mmol/g-dry-mat), respectively., and water uptake content showed a similar trend with IEC. and The selectivity coefficients $K^M_H$ of Cd(II), Ni((II) ions showed 0.324, 0.228. respectively.

Offset elimination in adaptive control (적응제어에서의 오프셋 영향 제거)

  • 최두환;김영철;양홍식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.236-241
    • /
    • 1988
  • This note considers the class of controllers with integral action which arise directly from appropriate system models. Via internal model principle approach, a corresponding class of self-tuning controller is shown to have both integral action in controller and offset removal in the tuning algorithm. The key idea is to constrain the estimator in each step in order to ensure that dc gain of feedforward and feedback polynomial of adaptive controller are always equal, thus allowing the loop integrator to work properly.

  • PDF

Computer simulation of the removal of the 0-th order diffraction by using fourier transform in digital holography (디지털 홀로그래피에서 퓨리어 변환을 이용한 0차 회절광의 제거와 위상홀로그램의 생성에 대한 전산 모사)

  • Kim, Sung-Kyu;Park, Min-Chul;Lee, Seok;Kim, Jae-Soon;Son, Jung-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • A computer simulation about removal of the 0-th order diffraction is achieved by using numerical reconstruction in digital holography and the Fourier transform method. A light intensity distribution hologram is generated through numerical calculation of the interference pattern. Additionally a phase hologram without the 0-th order diffraction is generated. The removal function for elimination of the 0-the order diffraction is introduced and the numerical reconstructions with several conditions for the removal of the 0-th order diffraction and the production of high quality numerically reconstructed images are tested and compared. The removal function is proven to be more effective at the suppression of the 0-th order diffraction compared with the DC suppression method.

A Study on the filtering bed of porous sintering-product and hydrophytes for sewage treatment (오·폐수처리를 위한 수생식물 다공성 소결체여상의 기초연구)

  • Kim, Ju-Hyung;Yun, Chan;Oh, Joon-Seong
    • Clean Technology
    • /
    • v.7 no.2
    • /
    • pp.89-97
    • /
    • 2001
  • The purpose of this study was to find the optimum condition of the high removal efficiency of water pollutant as sewage treatment technology using a filtering bed charged with porous sintering-pellet which was planted with hydrophytes. Experiment was carried out by changing concentration of water pollutants(COD, T-N, T-P), kind of hydrophyte, kinds of filtering material and size, and HRT. The result of removal efficiency was obtained as following: COD removal 73.8~87.1% for input concentration range of 50~450mg/L, T-N removal 61.3~77.3% for input concentration range of 7~124mg/L, T-P removal 89.5~99.1% for input concentration ranger of 3~27mg/L. In a comparative experiment of three kinds of hydrophyte(Iris pseudoacorus, Phragmites communis $T_{RIN}$., Oenanthe javanica Dc.), the best removal efficiency of COD and T-N was gained with Iris pse-udoacorus, and Phragmites communis $T_{RIN}$ showed better result than two hydrophytes for the removal efficiency of T-P. In a comparative experiment of four kinds of filtering-materials, the removal efficiencies were in the order of porous sintering-pellet, gravel, nonused-tire and nonused-concrete. It was found that for the porous sintering-pellet, the smaller its diameter, the better its result. In the filtering bed in which was charged with porous sintering-pellets of 5mm diameter and planted with Iris pseudoacorus, the removal efficiency of COD, T-N and T-P were over 80%, 70% and 90% under the concentration of COD 250mg/L, T-N 70mg/L and T-P 15mg/L for 24hrs treatment. Thus, we concluded that a filtering bed charged with porous sintering-pellet and planted with hydrophytes will be suitable for treatment of sewage water as a pro-natural treatment technology.

  • PDF

Eliminating Method of Estimated Magnetic Flux Offset in Flux based Sensorless Control of PM Synchronous Motor using High Pass filter with Variable Cutoff Frequency (모터 운전 주파수에 동기화된 차단주파수를 갖는 HPF(High pass filter)를 적용한 영구자석 동기전동기의 자속기반 센서리스 제어의 추정 자속 DC offset 제거 기법)

  • Kang, Ji-Hun;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.455-464
    • /
    • 2019
  • The sensorless control based on the flux linkage of PM synchronous motors has excellent position estimation characteristics at low speeds. However, a limitation arises because the integrator of flux estimator is saturated by the DC offset generated during the analog to digital conversion(ADC) process of the measured current. In order to overcome this limitation, HPF with a low cutoff frequency is used. However, the estimation performance is deteriorated (Ed- the verb deteriorate already includes the meaning of 'problem') at high speed due to the low cutoff frequency, and increasing the cutoff frequency of the HPF induces further problems of phase leading and initial starting failure at low speeds. In this paper, the cutoff frequency of HPF was synchronized to the operation frequency of the motor: at low speeds the cutoff frequency was set to low in order to reduce the phase leading of the estimated flux, and at high speeds it was set to high to raise the DC offset removal performance. As a result, the operating range was increased by 200%. Furthermore, a phase compensation algorithm is proposed to reduce the phase leading of the HPF to less than 1.5 degrees over the full operating range. The proposed sensorless control algorithm was verified by experiment with a PM synchronous motor for a washing machine.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Kt Factor Analysis of Lead-Acid Battery for Nuclear Power Plant

  • Kim, Daesik;Cha, Hanju
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.460-465
    • /
    • 2013
  • Electrical equipments of nuclear power plant are divided into class 1E and non-class 1E. Electrical equipment and systems that are essential to emergency reactor shutdown, containment isolation, reactor core cooling, and containment and reactor heat removal, are classified as class 1E. batteries of nuclear power plant are divided into four channels, which are physically and electrically separate and independent. The battery bank of class 1E DC power system of the nuclear power plant use lead-acid batteries in present. The lead acid battery, which has a high energy density, is the most popular form of energy storage. Kt factor of lead-acid battery is used to determine battery size and it is one of calculatiing coefficient for capacity. this paper analyzes Kt factor of lead-acid battery for the DC power system of nuclear power plant. In addition, correlation between Kt parameter and peukert's exponent of lead-acid battery for nuclear plant are discussed. The analytical results contribute to optimize of determining size Lead-acid battery bank.

Improvement in Wind Vector from UHF Wind Profiler Radar through Removing Ground Echo (지형에코 제거를 통한 UHF 윈드프로파일러의 바람벡터 개선)

  • Kim, Kwang-Ho;Kim, Park-Sa;Kim, Min-Seong;Kang, Dong-Hwan;Kwon, Byung Hyuk
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.267-280
    • /
    • 2016
  • Ground echo is radar return from stationary targets such as buildings and trees. Wind vectors from the wind profile radar in Gangneung are affected by ground echoes due to the complex mountainous terrain located to the west and the south. These ground echoes make a spurious peak close to the direct current (DC) line signal in Doppler spectra. Wind vectors polluted by ground clutters were determined from spectra of oblique beams. After eliminated the terrain echoes, the accuracy of wind vector compared with radiosonde was improved about 68.4% and its relative coefficient was increased from 0.58 to 0.97.

Development of an Urea Sensor using Electric Conductivity Method (전기전도도법을 이용한 우레아 농도 센서 개발)

  • Choi, B.C.;Kim, K.Y.;Yang, J.Y.;Kim, H.N.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • The popularity of diesel engines is derived primarily from their higher thermal efficiency resulting from higher compression ratio. NOx removal from the diesel emissions is very important to meet stringent emission regulations. NOx emission from diesel engines is removed by an urea-SCR or an LNT system. The urea-SCR system needs the urea-solution supply system with concentration and level sensor. This study was carried out to develop a sensor for the measurement of urea-solution concentration by an electric conductivity method. Considering experimental parameters were the material of electrode, two kinds of electric power(AC or DC), the distance between two electrodes, and the length of electrode. It was found that the AC electric power was more useful to measure the urea-solution concentration compared to DC, because it prevented an ionization of the urea-solution. The silver rod coated with Pt is the most useful electrode, tendency of which is similar to Pt rod, and the cost is more economic. We could also find out the optimum distance between two electrodes and the length of electrode was 10mm and 3mm, respectively.