Optimal Remediation of TCE-contaminated Groundwater using Direct Current and Fe$^0$ (직류전원과 0가 철을 이용한 지하수내 TCE정화효율의 최적화 연구)

  • Moon, Ji-Won;Moon, Hi-Soo;Roh, Yul;Kim, Heon-Ki;Song, Yun-Goo
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.229-239
    • /
    • 2002
  • The objective of this study was to design an optimal electro-remediation system for TCE contaminated water using zero talent iron (ZVI) and direct current (DC). A series of column experiments were conducted to evaluate the effects of electrode arrangement and the location of permeable iron barrier in the column on the TCE removal efficiency and iron corrosion process. In twelve different combinations of ZVI and/or DC application in the test columns, the rate of reductive degradation of TCE was improved with simultaneous application of both ZVI and DC compared to that used ZVI only. The moot effective arrangement of electrode and ZVI for TCE removal from water was a column set with ZVI and cathode installed at the down gradient, respectively.

Studies on Photocatalytic Thin Films($TiO_2$, TiO-N) Manufactured by DC Magnetron Sputtering Method and it's Characteristics for Removal of Pollutants (DC 마그네트론 스퍼터링법을 이용한 광촉매박막($TiO_2$, TiO-N)제조 및 오염물질 제거에 관한 연구)

  • Jeong, Weon-Sang;Park, Sang-Weon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2005
  • [ $TiO_2$ ] was deposited by DC magnetron sputtering on glass surface under various sputtering parameters such as discharge power($0.6{\sim}5.2\;kW$, substrate temperature($R.T{\sim}350^{\circ}C$), Ar and $O_2$ flow ratio with $0{\sim}50\;sccm$($Ar+O_2$ 90 sccm) and about 1 mtorr of pressure. TiO-N thin film was prepared under same sputtering conditions for $TiO_2$ thin film except flow ratio($Ar+O_2+N_2$ 90 sccm). The sheet resistance of thin films deposited under these parameters was measured to analyze electronic characteristic and thin film's thickness(${\alpha}$-step), surface roughness(AFM) and formation construction(FE-SEM, XRD) were also measured to draw optimal sputtering parameters. In order to evaluate photo-activity of thin film($TiO_2$, TiO-N) made in optimal parameters for removal of pollutants, toluene among VOCs and Suncion Yellow among reactive dyes were chosen to probe organic compounds for photo-degradation. It was shown that the photo-catalytic thin films had a significant photo-activation for the chosen contaminants and especially TiO-N thin film showed maximum efficiency of 33% for toluene(5 ppm) removal in visible-light range.

Bioremediation of Heavy Metals from the Land Application of Industrial Sewage Sludge with Minari (Oenanthe stolonifer DC.) Plant

  • Lee, Myoung-Sun;Youn, Se-Young;Yim, Sang-Choel;Park, Hee-Joun;Shin, Joung-Du
    • Plant Resources
    • /
    • v.1 no.1
    • /
    • pp.53-59
    • /
    • 1998
  • Laboratory experiments for the removal efficiency of heavy metals in land application of sludge, the accumulation and translocation of heavy metals in x plants after transplanting, and the responses of Minari growth with different ratio of land application of sludge were conducted to determine the potential ability of bioremediation with Minari plants. The removal rate and translocation of copper. zinc. lead. and cadmium in soil and plants were compared after transplanting the Minari plants to soil treated with different ratio of sludge. The removal efficiency of heavy metals in soil incorporated with sludge was different with application ratio, but increased with growing periods of Minari plants. The removal efficiency of Cu, Zn, Pb, and Cd ranged from 67 to 74% from 51% to 63%, from 37% to 71%. and from 15% to 25% after 45 days of transplanting. respectively. The amount removed the copper value. 65.9 mg/kg, observed to be highest in soil incorporated 3% sludge after 45 days. The translocation of Cu. Zn. Pb. and Cd from shoots to roots ranged from 18 to 53%, from 17 to 32%, from 14 to 49%, and from 23 to 38% over growing periods. respectively. In plant responses it appeared to be inhibited the plant growth in the treatment compared with the control at early stage of growth. However, the fresh weights of Minari plant increased from 12.5 to 62.5% in the sludge application after 45 days relative to the control. Therefore the Minari might play a useful role in bioremediation of Cu, Zn, Pb, and Cd in the land application of sludge.

  • PDF

Output Current DC offset Removal Method for Trans-less PV Inverter (무변압기형 태양광 인버터의 출력 전류 DC offset 제거 방법)

  • Hong, Ki-Nam;Choy, Ick;Choi, Ju-Yeop;Lee, Sang-Chul;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.255-261
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. And also, the switch device is not ideal, both each switching element of the voltage drop difference and on & off time delay difference generate DC offset. Thus, to compensate for deadtime and the switch voltage drop, feedback control by output current DC offset should be provided to compensate additional distortion of the output current. The validity of the proposed method is confirmed through PSIM simulation.

A Transimpedance Amplifier Employing a New DC Offset Cancellation Method for WCDMA/LTE Applications

  • Lee, Cheongmin;Kwon, Kuduck
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.825-831
    • /
    • 2016
  • In this paper, a transimpedance amplifier based on a new DC offset cancellation (DCOC) method is proposed for WCDMA/LTE applications. The proposed method applies a sample and hold mechanism to the conventional DCOC method with a DC feedback loop. It prevents the removal of information around the DC, so it avoids signal-to-noise ratio degradation. It also reduces area and power consumption. It was designed in a $0.13{\mu}m$ deep n-well CMOS technology and drew a maximum current of 1.58 mA from a 1.2 V supply voltage. It showed a transimpedance gain of $80dB{\Omega}$, an input-referred noise current lower than 0.9 pA/${\surd}$Hz, an out-of-band input-referred 3rd-order intercept point more than 9.5 dBm, and an output DC offset lower than 10 mV. Its area is $0.46mm{\times}0.48mm$.

A Study on the Enhanced Filtering for the Removal of BEMF in BLDC Motors

  • Moon, Yu-Sung;Choi, Jae-Hyun;Kim, Jung-Won
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.310-313
    • /
    • 2019
  • This paper used the majority function to digitally filter back-electromotive force as an explanation of the Brushless DC MOTOR control algorithm. The cause and improvement of motor noise, which are operating in close proximity to high frequency sources, did not use conventional low pass filter and comparator elements. Also, they repeatedly output a noise-free BEMF signal for the input value of the majority detection filtering. These filtering steps can help reduce costs and minimize the area of a PCB by requiring relatively little hardware.

SURFACE POTENTIAL DISTRIBUTION ON POLYMER INSULATORS

  • Kitani, Isamu
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.17-21
    • /
    • 1998
  • The surface potential distribution on insulating polymers was measured by scanning of the probe of an electrostatic voltmeter. The measurements were done for two measured by scanning of the probe of an electrostatis voltmeter. The measurements were done for two cases. In the first case, it was measured on the free surface of insulating films which had been inserted between plane electodes after the removal of the upper brass disk electrode. In the second case, we measured the charging region between a circular and its opposing concentric ring electrodes after the removal of dc ramp voltage in air and nitrogen gas.

  • PDF

Effects of Oxidizer Additive on the Performance of Copper-Chemical Mechanical Polishing using Tungsten Slurry (텅스텐 슬러리를 사용한 Cu-CMP 특성에서 산화제 첨가의 영향)

  • 이우선;최권우;이영식;최연옥;오용택;서용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.2
    • /
    • pp.156-161
    • /
    • 2004
  • We investigated the effects of oxidizer additive on the performance of Cu-CMP process using commonly used tungsten slurry. In order to compare the removal rate and non-uniformity as a function of oxidizer contents, we used alumina-based tungsten slurry and copper blanket wafers deposited by DC sputtering method. According to the CMP removal rates and particle size distribution, and the microstructures of surface layer by SEM image as a function or oxidizer contents were greatly influenced by the slurry chemical composition of oxidizers. The difference in removal rate and roughness of copper surface are believed to cause by modification in the mechanical behavior of $Al_2$O$_3$abrasive particles in CMP slurry.

A Study of Removal of Phenol by Peroxidase Extracted from Oenanthe javanica (Blume) DC (미나리 Peroxidase를 이용한 Phenol제거에 관한 연구)

  • 탁창준;최한영;신정식;나규환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.121-126
    • /
    • 1997
  • Peroxidase as one of the organic enzyme catalyst is useful for the oxidation treatment of various aromatic compounds such as phenols. The peroxidase content of Oenanthe javanica was 24.85 unit/g-fw in leaf, 5.74 unit/g-fw in stem, and 34.69 unit/g-fw in root respectively. The crude peroxidase extracted from Oenanthe javanka can be kept under low temperature (-70$\circ$C) condition for 6 months with the maximum 1% activity reduction. The optimum conditions of removal for 100 ppm phenol was pH 6, hydrogen peroxide 3.5 mM, peroxidase activity 8 unit/ml, temperature 20$\circ$C respectively. In the wide range of concentration from 50 ppm to 750 ppm phenol reveals average 54% removal rate under the same peroxidase activity (8 unit/ml) and different amount of hydrogen peroxide proportional to phenol concentration. Especially at the concentration of 100 ppm the maximum phenol removal rate was 72%.

  • PDF

Seedling Growth and Morphology as Influenced by Removal of Cotyledon and Unifoliolate in White Clover (자엽 및 단엽 제거에 따른 White Clover의 유묘기 생장과 형태적 특성)

  • 강진호;박진서;이희원
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.5
    • /
    • pp.480-488
    • /
    • 1994
  • Low seedling growth rates of white clover (Trifolium repens L.) have been limited its good establishment to pastures. The experiment was done to determine the effect of removal of cotyledon and unifoliolate on the growth and morphological characters of contrasting white clover cultivars for 8 weeks after the treatment. Individual plants of cv. Regal (large leaf), Louisiana S-l (medium-large leaf), Grasslands Huia (medium-small leaf) and Aberystwyth S184 (small leaf) were grown in 10cm plastic pot containing a 2:1:1 soil:sand:peat moss mixture until the cotyledon or unifoliolate stage and then removed one (C1) or two cotyledons (C2) at cotyledon stage, and unifoliolate only (U), unifoliolate and one cotyledon (DC1) or unifoliolate and two cotyledons (DC2) at the unifoliolate stage. To measure the removal effect on biomass and morphological characters (leaf area, petiole and stolon lengths, growing tips and leaves), plants were sampled 4, 6 and 8 weeks after the treatment. Intact plants had greater biomass and morphological characters than removal-treated ones, Removal treatments at cotyledon stage, C1 and C2, were decreased more biomass and morphological characters than removal ones at unifoliolate stage while the severer cotyledon removal, the more reduction. Stolon length per plant and petiole length markedly inclined 6 weeks after the treatments although biomass and the other characters continuously did. Relatively large-leaved cultivar had more biomass, leaf area per plant and longer petiole than the other(s) but the reverse results were true in stolon length, growing tips and no. of leaves per plant. Biomass was linearly increased with increased leaf area but the earlier and severer removal, the less slope. The severer damage of cotyledon and unifoliolate had detrimental effects on the growth and aftermath establishment of white clover

  • PDF